3,962 research outputs found

    Alternatives for a better program

    Get PDF
    Teaching teachers is not equal to telling teachers

    Wean Dairy Calves Early

    Get PDF
    Dairy calves can be weaned from milk at 1 month of age by feeding a palatable, nutritious starter. Here\u27s more about the early weaning program\u27s secret - getting the calves on starter at an early age

    Comparison of Astrand VO2 Max Prediction to a Graded Leg Ergometry VO2 Max Test in Endurance Athletes

    Get PDF
    Please refer to the pdf version of the abstract located adjacent to the title

    Concepts for increasing gentamicin release from handmade bone cement beads

    Get PDF
    Background and purpose Commercial gentamicin-loaded bone cement beads (Septopal) constitute an effective delivery system for local antibiotic therapy. These beads are not available in all parts of the world, and are too expensive for frequent use in others. Thus, orthopedic surgeons worldwide make antibiotic-loaded beads themselves. However, these beads are usually not as effective as the commercial beads because of inadequate release kinetics. Our purpose was to develop a simple, cheap, and effective formulation to prepare gentamicin-loaded beads with release properties and antibacterial efficacy similar to the commercially ones. Methods Acrylic beads were prepared with variable monomer content: 100% (500 μL/g polymer), 75%, and 50% to increase gentamicin release through creation of a less dense polymer matrix. Using the optimal monomer content, different gel-forming polymeric fillers were added to enhance the permeation of fluids into the beads. Polyvinylpyrrolidone (PVP) 17 was selected as a suitable filler; its concentration was varied and the antibiotic release and antibacterial efficacy of these beads were compared with the corresponding properties of the commercial ones. Results Gentamicin release rate and the extent of release from beads prepared with 50% monomer increased when the PVP17 content was increased. Beads with 15 w/w% PVP17 released 87% of their antibiotic content. This is substantially more than the gentamicin release from Septopal beads (59%). Acrylic beads with 15 w/w% PVP17 reduced bacterial growth by up to 93%, which is similar to the antibacterial properties of the commercial ones. Interpretation A simple, cheap, and effective formulation and preparation process has been described for hand-made gentamicin-releasing acrylic beads, with better release kinetics and with antibacterial efficacy similar to that of the commercial ones

    H_2 Emission From Disks Around Herbig Ae and T Tauri Stars

    Get PDF
    We present the initial results of a deep ISO-SWS survey for the low J pure rotational emission lines of H2 toward a number of Herbig Ae and T Tauri stars. The objects are selected to be as isolated as possible from molecular clouds, with a spectral energy distribution characteristic of a circumstellar disk. For most of them the presence of a disk has been established directly by millimeter interferometry. The S (1) line is detected in most sources with a peak flux of 0.3-1 Jy. The S(0) line is definitely seen in 2 objects: GG Tau and HD 163296. The observations suggest the presence of "warm" gas at T_(kin) ≈ 100 K with a mass of a few % of the total gas+ dust mass, derived assuming a gas-to-dust ratio of 100:1. The S(1) peak flux does not show a strong correlation with spectral type of the central star or continuum flux at 1.3 millimeter. Possible origins for the warm gas seen in H_2 are discussed, and comparisons with model calculations are made

    Nebulized heparin in burn patients with inhalation trauma : safety and feasibility

    Get PDF
    Background: Pulmonary hypercoagulopathy is intrinsic to inhalation trauma. Nebulized heparin could theoretically be beneficial in patients with inhalation injury, but current data are conflicting. We aimed to investigate the safety, feasibility, and effectiveness of nebulized heparin. Methods: International multicenter, double-blind, placebo-controlled randomized clinical trial in specialized burn care centers. Adult patients with inhalation trauma received nebulizations of unfractionated heparin (25,000 international unit (IU), 5 mL) or placebo (0.9% NaCl, 5 mL) every four hours for 14 days or until extubation. The primary outcome was the number of ventilator-free days at day 28 post-admission. Here, we report on the secondary outcomes related to safety and feasibility. Results: The study was prematurely stopped after inclusion of 13 patients (heparin N = 7, placebo N = 6) due to low recruitment and high costs associated with the trial medication. Therefore, no analyses on effectiveness were performed. In the heparin group, serious respiratory problems occurred due to saturation of the expiratory filter following nebulizations. In total, 129 out of 427 scheduled nebulizations were withheld in the heparin group (in 3 patients) and 45 out of 299 scheduled nebulizations were withheld in the placebo group (in 2 patients). Blood-stained sputum or expected increased bleeding risks were the most frequent reasons to withhold nebulizations. Conclusion: In this prematurely stopped trial, we encountered important safety and feasibility issues related to frequent heparin nebulizations in burn patients with inhalation trauma. This should be taken into account when heparin nebulizations are considered in these patients

    In situ observation of stress relaxation in epitaxial graphene

    Get PDF
    Upon cooling, branched line defects develop in epitaxial graphene grown at high temperature on Pt(111) and Ir(111). Using atomically resolved scanning tunneling microscopy we demonstrate that these defects are wrinkles in the graphene layer, i.e. stripes of partially delaminated graphene. With low energy electron microscopy (LEEM) we investigate the wrinkling phenomenon in situ. Upon temperature cycling we observe hysteresis in the appearance and disappearance of the wrinkles. Simultaneously with wrinkle formation a change in bright field imaging intensity of adjacent areas and a shift in the moire spot positions for micro diffraction of such areas takes place. The stress relieved by wrinkle formation results from the mismatch in thermal expansion coefficients of graphene and the substrate. A simple one-dimensional model taking into account the energies related to strain, delamination and bending of graphene is in qualitative agreement with our observations.Comment: Supplementary information: S1: Photo electron emission microscopy and LEEM measurements of rotational domains, STM data of a delaminated bulge around a dislocation. S2: Movie with increasing brightness upon wrinkle formation as in figure 4. v2: Major revision including new experimental dat

    Viscosity and Rotation in Core-Collapse Supernovae

    Full text link
    We construct models of core-collapse supernovae in one spatial dimension, including rotation, angular momentum transport, and viscous dissipation employing an alpha-prescription. We compare the evolution of a fiducial 11 M_sun non-rotating progenitor with its evolution including a wide range of imposed initial rotation profiles (1.25<P_0<8 s, where P_0 is the initial, approximately solid-body, rotation period of the iron core). This range of P_0 covers the region of parameter space from where rotation begins to modify the dynamics (P_0~8 s) to where angular velocities at collapse approach Keplerian (P_0~1 s). Assuming strict angular momentum conservation, all models in this range leave behind neutron stars with spin periods <10 ms, shorter than those of most radio pulsars, but similar to those expected theoretically for magnetars at birth. A fraction of the gravitational binding energy of collapse is stored in the free energy of differential rotation. This energy source may be tapped by viscous processes, providing a mechanism for energy deposition that is not strongly coupled to the mass accretion rate through the stalled supernova shock. This effect yields qualitatively new dynamics in models of supernovae. We explore several potential mechanisms for viscosity in the core-collapse environment: neutrino viscosity, turbulent viscosity caused by the magnetorotational instability (MRI), and turbulent viscosity by entropy- and composition-gradient-driven convection. We argue that the MRI is the most effective. We find that for rotation periods in the range P_0<~5 s, and a range of viscous stresses, that the post-bounce dynamics is significantly effected by the inclusion of this extra energy deposition mechanism; in several cases we obtain strong supernova explosions.Comment: accepted to ApJ, references added, discussion tightened, 26 pages, 11 figures, emulateap

    Patient-Tailored Connectomics Visualization for the Assessment of White Matter Atrophy in Traumatic Brain Injury

    Get PDF
    Available approaches to the investigation of traumatic brain injury (TBI) are frequently hampered, to some extent, by the unsatisfactory abilities of existing methodologies to efficiently define and represent affected structural connectivity and functional mechanisms underlying TBI-related pathology. In this paper, we describe a patient-tailored framework which allows mapping and characterization of TBI-related structural damage to the brain via multimodal neuroimaging and personalized connectomics. Specifically, we introduce a graphically driven approach for the assessment of trauma-related atrophy of white matter connections between cortical structures, with relevance to the quantification of TBI chronic case evolution. This approach allows one to inform the formulation of graphical neurophysiological and neuropsychological TBI profiles based on the particular structural deficits of the affected patient. In addition, it allows one to relate the findings supplied by our workflow to the existing body of research that focuses on the functional roles of the cortical structures being targeted. A graphical means for representing patient TBI status is relevant to the emerging field of personalized medicine and to the investigation of neural atrophy
    corecore