11 research outputs found

    Anterior eye surface changes following miniscleral contact lens wear

    Get PDF
    Purpose To quantify the effect of short-term miniscleral contact lens wear on the anterior eye surface of healthy eyes, including cornea, corneo-scleral junction and sclero-conjuctival area. Methods Twelve healthy subjects (29.9 ± 5.7 years) wore a highly gas-permeable miniscleral contact lens of 16.5 mm diameter during a 5-hour period. Corneo-scleral height profilometry was captured before, immediately following lens removal and 3 h after lens removal. Topography based corneo-scleral limbal radius estimates were derived from height measurements. In addition, elevation differences in corneal and scleral region were calculated with custom-written software. Sclero-conjuctival flattening within different sectors was analysed. Results Short-term miniscleral lens wear significantly modifies the anterior eye surface. Significant limbal radius increment (mean ± standard deviation) of 146 ± 80 μm, (p = 0.004) and flattening of −122 ± 90 μm in the sclero-conjuctival area, (p << 0.001) were observed immediately following lens removal. These changes did not recede to baseline levels 3 h after lens removal. The greatest anterior eye surface flattening was observed in the superior sector. No statistically significant corneal shape change was observed immediately following lens removal or during the recovery period. Conclusions Short-term miniscleral contact lens wear in healthy eyes does not produce significant corneal shape changes measured with profilometry but alters sclero-conjuctival topography. In addition, sclero-conjuctival flattening was not uniformly distributed across the anterior eye

    Experimental and clinical radiofrequency ablation: proposal for standardized description of coagulation size and geometry.

    No full text
    BACKGROUND: Radiofrequency (RF) ablation is used to obtain local control of unresectable tumors in liver, kidney, prostate, and other organs. Accurate data on expected size and geometry of coagulation zones are essential for physicians to prevent collateral damage and local tumor recurrence. The aim of this study was to develop a standardized terminology to describe the size and geometry of these zones for experimental and clinical RF. METHODS: In a first step, the essential geometric parameters to accurately describe the coagulation zones and the spatial relationship between the coagulation zones and the electrodes were defined. In a second step, standard terms were assigned to each parameter. RESULTS: The proposed terms for single-electrode RF ablation include axial diameter, front margin, coagulation center, maximal and minimal radius, maximal and minimal transverse diameter, ellipticity index, and regularity index. In addition a subjective description of the general shape and regularity is recommended. CONCLUSIONS: Adoption of the proposed standardized description method may help to fill in the many gaps in our current knowledge of the size and geometry of RF coagulation zones

    Sorting out river channel patterns

    No full text
    corecore