1,070 research outputs found

    Accurate assessment of abdominal aortic aneurysm with intravascular ultrasound scanning: Validation with computed tomographic angiography

    Get PDF
    AbstractPurpose: The purpose of this study was to assess the accuracy of intravascular ultrasound (IVUS) parameters of abdominal aortic aneurysm, used for endovascular grafting, in comparison with computed tomographic angiography (CTA). Methods: This study was designed as a descriptive study. Between March 1997 and March 1998, 16 patients with abdominal aortic aneurysms were studied with angiography, IVUS (12.5 MHz), and CTA. The length of the aneurysm and the length and lumen diameter of the proximal and distal neck obtained with IVUS were compared with the data obtained with CTA. The measurements with IVUS were repeated by a second observer to assess the reproducibility. Tomographic IVUS images were reconstructed into a longitudinal format. Results: IVUS results identified 31 of 32 renal arteries and four of five accessory renal arteries. A comparison of the length measurements of the aneurysm and the proximal and distal neck obtained with IVUS and CTA revealed a correlation of 0.99 (P < .001), with a coefficient of variation of 9%. IVUS results tended to underestimate the length as compared with the CTA results (0.48 ± 0.52 cm; P < .001). A comparison of the lumen diameter measurements of the proximal and distal neck derived from IVUS and CTA showed a correlation of 0.93 (P < .001), with a coefficient of variation of 9%. IVUS results tended to underestimate aneurysm neck diameter as compared with CTA results (0.68 ± 1.76 mm; P = .006). Interobserver agreement of IVUS length and diameter measurements showed a good correlation (r = 1.0; P < .001), with coefficients of variation of 3% and 2%, respectively, and no significant differences (0.0 ± 0.16 cm and 0.06 ± 0.36 mm, respectively). The longitudinal IVUS images displayed the important vascular structures and improved the spatial insight in aneurysmal anatomy. Conclusion: Intravascular ultrasound scanning results provided accurate and reproducible measurements of abdominal aortic aneurysm. The longitudinal reconstruction of IVUS images provided additional knowledge on the anatomy of the aneurysm and its proximal and distal neck. (J Vasc Surg 1999;29:631-8.

    Improving the quality of palliative and terminal care in the hospital by a network of palliative care nurse champions: The study protocol of the PalTeC-H project

    Get PDF
    Background: The quality of care of patients dying in the hospital is often judged as insufficient. This article describes the protocol of a study to assess the quality of care of the dying patient and the contribution of an intervention targeted on staff nurses of inpatient wards of a large university hospital in the Netherlands. Methods/Design. We designed a controlled before and after study. The intervention is the establishment of a network for palliative care nurse champions, aiming to improve the quality of hospital end-of-life care. Assessments are performed among bereaved relatives, nurses and physicians on seven wards before and after introduction of the intervention and on 11 control wards where the intervention is not applied. We focus on care provided during the last three days of life, covered in global ratings of the quality of life in the last three days of life and the quality of dying, and various secondary endpoints of treatment and care affecting quality of life and dying. Discussion. With this study we aim to improve the understanding of and attention for patients' needs, and the quality of care in the dying phase in the hospital and measure the impact of a quality improvement intervention targeted at nurses

    Orthopedic surgery increases atherosclerotic lesions and necrotic core area in ApoE-/- mice

    Get PDF
    Background and aims Observational studies show a peak incidence of cardiovascular events after major surgery. For example, the risk of myocardial infarction increases 25-fold early after hip replacement. The acuteness of this increased risk suggests abrupt enhancement in plaque vulnerability, which may be related to intra-plaque inflammation, thinner fibrous cap and/or necrotic core expansion. We hypothesized that acute systemic inflammation following major orthopedic surgery induces such changes. Methods ApoE−/− mice were fed a western diet for 10 weeks. Thereafter, half the mice underwent mid-shaft femur osteotomy followed by realignment with an intramedullary K-wire, to mimic major orthopedic surgery. Mice were sacrificed 5 or 15 days post-surgery (n = 22) or post-saline injection (n = 13). Serum amyloid A (SAA) was measured as a marker of systemic inflammation. Paraffin embedded slides of the aortic root were stained to measure total plaque area and to quantify fibrosis, calcification, necrotic core, and inflammatory cells. Results Surgery mice showed a pronounced elevation of serum amyloid A (SAA) and developed increased plaque and necrotic core area already at 5 days, which reached significance at 15 days (p = 0.019; p = 0.004 for plaque and necrotic core, respectively). Macrophage and lymphocyte density significantly decreased in the surgery group compared to the control group at 15 days (p = 0.037; p = 0.024, respectively). The density of neutrophils and mast cells remained unchanged. Conclusions Major orthopedic surgery in ApoE−/− mice triggers a systemic inflammatory response. Atherosclerotic plaque area is enlarged after surgery mainly due to an increase of the necrotic core. The role of intra-plaque inflammation in this response to surgical injury remains to be fully elucidated. © 2016 Elsevier Ireland Lt

    Novel metallic implantation technique for osteochondral defects of the medial talar dome: A cadaver study

    Get PDF
    BACKGROUND AND PURPOSE: A metallic inlay implant (HemiCAP) with 15 offset sizes has been developed for the treatment of localized osteochondral defects of the medial talar dome. The aim of this study was to test the following hypotheses: (1) a matching offset size is available for each talus, (2) the prosthetic device can be reproducibly implanted slightly recessed in relation to the talar cartilage level, and (3) with this implantation level, excessive contact pressures on the opposite tibial cartilage are avoided. METHODS: The prosthetic device was implanted in 11 intact fresh-frozen human cadaver ankles, aiming its surface 0.5 mm below cartilage level. The implantation level was measured at 4 margins of each implant. Intraarticular contact pressures were measured before and after implantation, with compressive forces of 1,000-2,000 N and the ankle joint in plantigrade position, 10 dorsiflexion, and 14 plantar flexion. RESULTS: There was a matching offset size available for each specimen. The mean implantation level was 0.45 (SD 0.18) mm below the cartilage surface. The defect area accounted for a median of 3% (0.02-18) of the total ankle contact pressure before implantation. This was reduced to 0.1% (0.02-13) after prosthetic implantation. INTERPRETATION: These results suggest that the implant can be applied clinically in a safe way, with appropriate offset sizes for various talar domes and without excessive pressure on the opposite cartilag

    Validity of absolute intake and nutrient density of protein, potassium, and sodium assessed by various dietary assessment methods:An exploratory study

    Get PDF
    It is suggested that nutrient densities are less affected by measurement errors than absolute intake estimates of dietary exposure. We compared the validity of absolute intakes and densities of protein (kJ from protein/total energy (kJ)), potassium, and sodium (potassium or sodium (in mg)/total energy (kJ)) assessed by different dietary assessment methods. For 69 Dutch subjects, two duplicate portions (DPs), five to fifteen 24-h dietary recalls (24 hRs, telephone-based and web-based) and two food frequency questionnaires (FFQs) were collected and compared to duplicate urinary biomarkers and one or two doubly labelled water measurements. Multivariate measurement error models were used to estimate validity coefficients (VCs) and attenuation factors (AFs). This research showed that group bias diminished for protein and sodium densities assessed by all methods as compared to the respective absolute intakes, but not for those of potassium. However, the VCs and AFs for the nutrient densities did not improve compared to absolute intakes for all four methods; except for the AF of sodium density (0.71) or the FFQ which was better than that of the absolute sodium intake (0.51). Thus, using nutrient densities rather than absolute intakes does not necessarily improve the performance of the DP, FFQ, or 24 hR.</p

    Distribution of Cardioembolic Stroke:A Cohort Study

    Get PDF
    Background: A cardiac origin in ischemic stroke is more frequent than previously assumed, but it is not clear which patients benefit from cardiac work-up if obvious cardiac pathology is absent. We hypothesized that thromboembolic stroke with a cardiac source occurs more frequently in the posterior circulation compared with thromboembolic stroke of another etiology. Methods: We performed a multicenter observational study in 3,311 consecutive patients with ischemic stroke who were enrolled in an ongoing prospective stroke registry of 8 University hospitals between September 2009 and November 2014 in The Netherlands. In this initiative, the so-called Parelsnoer Institute-Cerebrovascular Accident Study Group, clinical data, imaging, and biomaterials of patients with stroke are prospectively and uniformly collected. We compared the proportions of posterior stroke location in patients with a cardiac stroke source with those with another stroke etiology and calculated risk ratios (RR) with corresponding 95% CI with Poisson regression analyses. To assess which patient or disease characteristics were most strongly associated with a cardiac etiology in patients with ischemic stroke, we performed a stepwise backward regression analysis. Results: For the primary aim, 1,428 patients were eligible for analyses. The proportion of patients with a posterior stroke location among patients with a cardiac origin of their stroke (28%) did not differ statistically significant to those with another origin (25%), age and sex adjusted RR 1.16; 95% CI 0.96-1.41. For the secondary aim, 1,955 patients were eligible for analyses. No recent history of smoking, no hyperlipidemia, coronary artery disease, a higher age, and a higher National Institutes of Health Stroke Scale (NIHSS) score were associated with a cardiac etiology of ischemic stroke. Conclusions: We could not confirm our hypothesis that thromboembolic stroke localized in the posterior circulation is associated with a cardioembolic source of ischemic stroke, and therefore posterior stroke localization on itself does not necessitate additional cardiac examination. The lack of determinants of atherosclerosis, for example, no recent history of smoking and no hyperlipidemia, coronary artery disease, a higher age, and a higher NIHSS score are stronger risk factors for a cardiac source of ischemic stroke

    Nonadherence in hemodialysis: Associations with mortality, hospitalization, and practice patterns in the DOPPS

    Get PDF
    Nonadherence in hemodialysis: Associations with mortality, hospitalization, and practice patterns in the DOPPS.BackgroundNonadherence among hemodialysis patients compromises dialysis delivery, which could influence patient morbidity and mortality. The Dialysis Outcomes and Practice Patterns Study (DOPPS) provides a unique opportunity to review this problem and its determinants on a global level.MethodsNonadherence was studied using data from the DOPPS, an international, observational, prospective hemodialysis study. Patients were considered nonadherent if they skipped one or more sessions per month, shortened one or more sessions by more than 10 minutes per month, had a serum potassium level openface>6.0mEq/L, a serum phosphate level openface>7.5mg/dL (>2.4mmol/L), or interdialytic weight gain (IDWG)>5.7% of body weight. Predictors of nonadherence were identified using logistic regression. Survival analysis used the Cox proportional hazards model adjusting for case-mix.ResultsSkipping treatment was associated with increased mortality [relative risk (RR) = 1.30, P = 0.01], as were excessive IDWG (RR = 1.12, P = 0.047) and high phosphate levels (RR = 1.17, P = 0.001). Skipping also was associated with increased hospitalization (RR = 1.13, P = 0.04), as were high phosphate levels (RR = 1.07, P = 0.05). Larger facility size (per 10 patients) was associated with higher odds ratios (OR) of skipping (OR = 1.03, P = 0.06), shortening (OR = 1.03, P = 0.05), and IDWG (OR = 1.02, P = 0.07). An increased percentage of highly trained staff hours was associated with lower OR of skipping (OR = 0.84 per 10%, P = 0.02); presence of a dietitian was associated with lower OR of excessive IDWG (OR = 0.75, P = 0.08).ConclusionNonadherence was associated with increased mortality risk (skipping treatment, excessive IDWG, and high phosphate) and with hospitalization risk (skipping, high phosphate). Certain patient/facility characteristics also were associated with nonadherence
    • …
    corecore