943 research outputs found

    FIL SSF intraocular lens opacification after pars plana vitrectomy with gas tamponade for traumatic lens luxation and retinal detachment: a case report and literature review

    Get PDF
    Background: To report a case of sutureless scleral-fixated hydrophilic intraocular lens (FIL SSF IOL, Soleko, Italy) opacification following pars plana vitrectomy surgery using sulfur hexafluoride (SF6) for traumatic lens luxation associated with retinal detachment. Case presentation: A 77-year-old woman was referred to our emergency department after blunt trauma in her right eye. At the ophthalmic evaluation, visual acuity was hand movement, biomicroscopy showed pseudoexfoliation syndrome and a traumatic lens luxation in the vitreous chamber. The patient underwent pars plana vitrectomy, subluxated cataract explantation, and FIL SSF IOL implant. During surgery, an inferior retinal detachment was encountered, requiring 20% SF6 gas tamponade. No adverse events were encountered. One month postoperatively, visual acuity (BCVA) improved to 0,3 logMAR. At the 3-month follow-up, the patient presented with BCVA of 0,5 logMAR, and biomicroscopy showed a minimal IOL opacification. Six months postoperatively, BCVA decreased to 1.0 logMAR, and diffuse, IOL opacification was noted at slit lamp examination. The patient refused any other surgical intervention for IOL exchange. Conclusions: Although hydrophilic IOL opacification gas related is known, to the best of our knowledge, this is the first case reported in the literature of FIL SSF IOL opacification after pars plana vitrectomy with gas tamponade for retinal detachment

    Epidemiology, clinical features, and surgical outcomes of acute acquired concomitant esotropia associated with myopia

    Get PDF
    Purpose: To analyze epidemiology, clinical features, and surgical outcomes of type III acute acquired concomitant esotropia (Bielschowsky esotropia (BE)). Methods: The medical charts of patients diagnosed with acquired concomitant esotropia between 2013 and 2021 were reviewed. Assessed data were age, gender, age at diplopia onset, age at the diagnosis, refraction, visual acuity, neuroimaging, diplopia onset, angle of deviation, stereopsis, surgical procedure, amount of surgery, and relapse of diplopia after surgery. Moreover, we investigated the correlation between the use of electronic devices and the onset of diplopia. Results: One hundred seventeen patients (mean age 35.07 ± 15.81 years) were included in the study. The mean delay to the diagnosis was 3.29 ± 3.62 years. Myopia range was 0 to 17 diopters spherical equivalent. 66,3% spent more than 4 hours a day using laptops, tablets, or smartphones at the onset of diplopia, and 90,6% presented a subacute onset. None showed neurologic signs or symptoms. Patients who underwent surgery were ninety-three, with a rate of surgical success of 93.6%, and a relapse rate of 17.2%. A negative correlation resulted between pre-operative deviation and age at diagnosis (ρ = -0.261; p<0.05), whereas factors associated with surgical failure were older age at diplopia onset (p = 0.042) and longer delay between onset and diagnosis (p = 0.002). Conclusion: We registered an outstanding increase in prevalence of BE, which could be related to the exponential increase in the use of electronic devices for professional, educational, and recreational purposes. A prompt diagnosis and an augmented dose of surgery allows good motor and sensory results

    Characterization of Pupillary Light Response Features for the Classification of Patients with Optic Neuritis

    Get PDF
    Pupillometry is a promising technique for the potential diagnosis of several neurological pathologies. However, its potential is not fully explored yet, especially for prediction purposes and results interpretation. In this work, we analyzed 100 pupillometric curves obtained by 12 subjects, applying both advanced signal processing techniques and physics methods to extract typically collected features and newly proposed ones. We used machine learning techniques for the classification of Optic Neuritis (ON) vs. Healthy subjects, controlling for overfitting and ranking the features by random permutation, following their importance in prediction. All the extracted features, except one, turned out to have significant importance for prediction, with an average accuracy of 76%, showing the complexity of the processes involved in the pupillary light response. Furthermore, we provided a possible neurological interpretation of this new set of pupillometry features in relation to ON vs. Healthy classification

    Growing old with antiretroviral therapy or elderly people in antiretroviral therapy: two different profiles of comorbidity?

    Get PDF
    Background In persons living with HIV (PLWH), the burden of non-communicable chronic diseases increased over time, because of aging associated with chronic inflammation, systemic immune activation, and long-term exposure to the combination antiretroviral therapy (ART). Methods To explore the association of chronological age, age at first ART, and exposure to ART with non-communicable chronic diseases, we performed a cross-sectional analysis to evaluate the prevalence of comorbidities in patients enrolled in the SCOLTA Project, stratified by groups of chronological age (50-59 and 60-69 years) and by years of antiretroviral treatment (ART, <= 3 or > 3 years). Results In 1394 subjects (23.8% women), mean age at enrollment was 57.4 (SD 6.5) years, and at first ART 45.3 (SD 10.7). Men were older than women both at enrollment (57.6 vs 56.8, p = 0.06) and at first ART (45.8 vs 43.6, p = 0.0009). ART duration was longer in women (13.1 vs 11.7 years, p = 0.01). The age- and sex-adjusted rate ratios (aRRs, and 95% confidence interval, CI) showed that longer ART exposure was associated with dyslipidemia (aRR 1.35, 95% CI 1.20-1.52), hypertension (aRR 1.52, 95% CI 1.22-1.89), liver disease (aRR 1.78, 95% CI 1.32-2.41), osteopenia/osteoporosis (aRR 2.88, 95% CI 1.65-5.03) and multimorbidity (aRR 1.36, 95% CI 1.21-1.54). These findings were confirmed in strata of age, adjusting for sex. Conclusions Our data suggest that longer ART exposure was associated with increased risk of dyslipidemia, hypertension, and osteopenia/osteoporosis, hence the presence of multimorbidity, possibly due to the exposition to more toxic antiretrovirals. We observed different comorbidities, according to ART exposure and age

    Mirror production for the Cherenkov telescopes of the ASTRI Mini-Array and of the MST project for the Cherenkov Telescope Array

    Get PDF
    The Cherenkov Telescope Array (CTA) is the next ground-based γ\gamma-ray observatory in the TeV γ\gamma-ray spectral region operating with the Imaging Atmospheric Cherenkov Technique. It is based on almost 70 telescopes of different class diameters - LST, MST and SST of 23, 12, and 4 m, respectively - to be installed in two sites in the two hemispheres (at La Palma, Canary Islands, and near Paranal, Chile). Several thousands of reflecting mirror tiles larger than 1 m2^2 will be produced for realizing the segmented primary mirrors of a so large number of telescopes. Almost in parallel, the ASTRI Mini-Array (MA) is being implemented in Tenerife (Canary Islands), composed of nine 4 m diameter dual-mirror Cherenkov telescopes (very similar to the SSTs). We completed the mirror production for all nine telescopes of the ASTRI MA and two MST telescopes (400 segments in total) using the cold glass slumping replication technology. The results related to the quality achieved with a so large-scale production are presented, also discussing the adopted testing methods and approaches. They will be very useful for the adoption and optimization of the quality assurance process for the huge production (almost 3000 m2^2 of reflecting surface) of the MST and SST CTA telescopes

    Quick, accurate, smart: 3D computer vision technology helps assessing confined animals' behaviour

    Get PDF
    Mankind directly controls the environment and lifestyles of several domestic species for purposes ranging from production and research to conservation and companionship. These environments and lifestyles may not offer these animals the best quality of life. Behaviour is a direct reflection of how the animal is coping with its environment. Behavioural indicators are thus among the preferred parameters to assess welfare. However, behavioural recording (usually from video) can be very time consuming and the accuracy and reliability of the output rely on the experience and background of the observers. The outburst of new video technology and computer image processing gives the basis for promising solutions. In this pilot study, we present a new prototype software able to automatically infer the behaviour of dogs housed in kennels from 3D visual data and through structured machine learning frameworks. Depth information acquired through 3D features, body part detection and training are the key elements that allow the machine to recognise postures, trajectories inside the kennel and patterns of movement that can be later labelled at convenience. The main innovation of the software is its ability to automatically cluster frequently observed temporal patterns of movement without any pre-set ethogram. Conversely, when common patterns are defined through training, a deviation from normal behaviour in time or between individuals could be assessed. The software accuracy in correctly detecting the dogs' behaviour was checked through a validation process. An automatic behaviour recognition system, independent from human subjectivity, could add scientific knowledge on animals' quality of life in confinement as well as saving time and resources. This 3D framework was designed to be invariant to the dog's shape and size and could be extended to farm, laboratory and zoo quadrupeds in artificial housing. The computer vision technique applied to this software is innovative in non-human animal behaviour science. Further improvements and validation are needed, and future applications and limitations are discussed.</p

    VERT-X: VERTical X-ray raster-scan facility for ATHENA calibration. The concept design

    Get PDF
    Calibration of the ATHENA telescope is a critical aspect of the project and raises significant difficulties due to the unprecedented size, mass and focal length of the mirror assembly. The VERT-X project, financed by ESA and started in January 2019 by a Consortium led by INAF and which includes EIE, Media Lario Technologies, GPAP, and BCV Progetti, aims to design an innovative calibration facility. In the VERT-X design the parallel beam, needed for calibration, is produced placing a source in the focus of an X-ray collimator. This system is mounted on a raster-scan mechanism which covers the entire ATHENA optics. The compactness of the VERT-X design allows a vertical geometry for the ATHENA calibration facility, with several potential benefits with respect to the long horizontal tube calibration facilities

    La Provincia di Sassari: ambiente, storia, civiltà

    Get PDF
    Essere cittadino di una provincia non significa soltanto abitarvi. Significa anche lavorarvi, esercitarvi una attività che vada a vantaggio del benessere individuale e insieme del benessere della collettività. Per fare questo, per raggiungere meglio questo obiettivo, la realtà in cui si vive e si lavora bisogna conoscerla meno superficialmente di quanto normalmente non succeda. E' una constatazione che si può fare per tutti coloro che abitano in un luogo, ma che si deve fare in modo particolare quando lo strumento di conoscenza che si propone è un libro come questo

    Cartel Stability under an Optimal Sharing Rule

    Full text link
    corecore