55 research outputs found

    Long Term Performance Of Passive House Buildings

    Get PDF
    Long term experience with Passive House buildings is illustrated with two early large scale projects, a school and an office building located in Germany. Those were monitored in lump energy performance (school, commissioned 2004) and great detail (office, commissioned 2002) respectively. Moreover, they give an indication of the characteristics of such buildings subject to changes in usage intensity. Both buildings generally performed as expected with the school facing occasional overheating in the summer due to inflexible shading controls. Following an extension in schooling hours the addition of a canteen was required and the ventilation system was adapted to the changed usage. Nevertheless the building’s user comfort and energy performance remain high,despite exceeding the Passive House primary energy target slightly due to increased electricity consumption. The office likewise meets the calculated efficiency in operation. The ground coupled cooling worked well despite greatly increased internal heat gains due to unexpected usage. This extra heat input did not, however, exhaust the geothermal (passive) cooling capacity for the future. Thermal comfort proved near optimal at all times, despite a very simple control regime of the one-circuit concrete core activation system for heating and cooling. In the last section air tightness design and measurement experience in the UK and particularly the question of long-term stability of the airtight building envelope is assessed. It was found that measurement results are not only repeatable in relatively short intervals such as a few months. The data available suggests stability of the airtight envelope over many years. Attention is required as regards the leakage of party walls of terraced buildings which need to be integrated in the overall airtightness concept. A high permeability of party walls in terraced buildings with a common airtight envelope presents a challenge for measuring air tightness. Long-term series of airtightness measurements exist for the Kranichstein House in Darmstadt/Germany and prove the stability of the chosen airtightness concept. Moreover, results for 17 early Passive House buildings in Germany in eight locations and various construction types revisited in 2001 (1.4 to 10 years after the initial airtightness test) suggest stability of air tightness values over time. Great advances have since been made in materials and methods available and the general understanding in the industry. This is supported by a large sample of 2934 Passive House projects of varied construction materials, locations, sizes and usages that yielded an average air tightness test result as low as n50 = 0.41 h-1

    Extrasystoles for fluid responsiveness prediction in critically ill patients

    Get PDF
    Background: Fluid responsiveness prediction with continuously available monitoring is an unsettled matter for the vast majority of critically ill patients, and development of new and reliable methods is desired. We hypothesized that the post-ectopic beat, which is associated with increased preload, could be analyzed in relation to preceding sinus beats and that the change in cardiac performance (e.g., systolic blood pressure) at the post-ectopic beat could predict fluid responsiveness. Methods: Critically ill patients were observed when scheduled for a 500-ml volume expansion. The 30-min ECG prior to volume expansion was analyzed for the occurrence of extrasystoles. Classification variables were defined as the change in a variable (e.g., systolic blood pressure or pre-ejection period) from the median of ten preceding sinus beats to extrasystolic post-ectopic beat. A stroke volume increase > 10% following volume expansion defined fluid responsiveness. Results: Twenty-six patients were included. The change in systolic blood pressure predicted fluid responsiveness with receiver operating characteristic (ROC) area 0.79 (CI [0.52:1.00]), specificity 100%, sensitivity 67%, positive predictive value 100%, and negative predictive value 91% (threshold: 5%). The change in pre-ejection period predicted fluid responsiveness with ROC area 0.74 (CI [0.53:0.94]), specificity 78%, sensitivity 67%, positive predictive value 50%, and negative predictive value 88% (threshold 7.5 ms). Conclusions: Based on standard critical care monitoring, analysis of the extrasystolic post-ectopic beat predicts fluid responsiveness in critical care patients with good accuracy. The presented results are considered preliminary proof-of-concept results, and further validation is needed to confirm these preliminary findings

    Senicapoc treatment in COVID-19 Patients with Severe Respiratory Insufficiency - A Randomized, Open-Label, Phase II Trial

    Get PDF
    BACKGROUND: The aim of the current study was to determine if treatment with senicapoc, improves the PaO(2)/FiO(2) ratio in patients with COVID‐19 and severe respiratory insufficiency. METHODS: Investigator‐initiated, randomized, open‐label, phase II trial in four intensive care units (ICU) in Denmark. We included patients aged ≥18 years and admitted to an ICU with severe respiratory insufficiency due to COVID‐19. The intervention consisted of 50 mg enteral senicapoc administered as soon as possible after randomization and again after 24 h. Patients in the control group received standard care only. The primary outcome was the PaO(2)/FiO(2) ratio at 72 h. RESULTS: Twenty patients were randomized to senicapoc and 26 patients to standard care. Important differences existed in patient characteristics at baseline, including more patients being on non‐invasive/invasive ventilation in the control group (54% vs. 35%). The median senicapoc concentration at 72 h was 62.1 ng/ml (IQR 46.7–71.2). The primary outcome, PaO(2)/FiO(2) ratio at 72 h, was significantly lower in the senicapoc group (mean 19.5 kPa, SD 6.6) than in the control group (mean 24.4 kPa, SD 9.2) (mean difference −5.1 kPa [95% CI −10.2, −0.04] p = .05). The 28‐day mortality in the senicapoc group was 2/20 (10%) compared with 6/26 (23%) in the control group (OR 0.36 95% CI 0.06–2.07, p = .26). CONCLUSIONS: Treatment with senicapoc resulted in a significantly lower PaO(2)/FiO(2) ratio at 72 h with no differences for other outcomes

    Seeking legitimacy through CSR: Institutional Pressures and Corporate Responses of Multinationals in Sri Lanka

    Get PDF
    Arguably, the corporate social responsibility (CSR) practices of multinational enterprises (MNEs) are influenced by a wide range of both internal and external factors. Perhaps most critical among the exogenous forces operating on MNEs are those exerted by state and other key institutional actors in host countries. Crucially, academic research conducted to date offers little data about how MNEs use their CSR activities to strategically manage their relationship with those actors in order to gain legitimisation advantages in host countries. This paper addresses that gap by exploring interactions between external institutional pressures and firm-level CSR activities, which take the form of community initiatives, to examine how MNEs develop their legitimacy-seeking policies and practices. In focusing on a developing country, Sri Lanka, this paper provides valuable insights into how MNEs instrumentally utilise community initiatives in a country where relationship-building with governmental and other powerful non-governmental actors can be vitally important for the long-term viability of the business. Drawing on neo-institutional theory and CSR literature, this paper examines and contributes to the embryonic but emerging debate about the instrumental and political implications of CSR. The evidence presented and discussed here reveals the extent to which, and the reasons why, MNEs engage in complex legitimacy-seeking relationships with Sri Lankan institutions

    Fraction of Inspired Oxygen During General Anesthesia for Non-Cardiac Surgery:Systematic Review and Meta-Analysis

    Get PDF
    BACKGROUND: Controversy exists regarding the effects of a high versus a low intraoperative fraction of inspired oxygen (FiO(2)) in adults undergoing general anesthesia. This systematic review and meta‐analysis investigated the effect of a high versus a low FiO(2) on postoperative outcomes. METHODS: PubMed and Embase were searched on March 22, 2022 for randomized clinical trials investigating the effect of different FiO(2) levels in adults undergoing general anesthesia for non‐cardiac surgery. Two investigators independently reviewed studies for relevance, extracted data, and assessed risk of bias. Meta‐analyses were performed for relevant outcomes, and potential effect measure modification was assessed in subgroup analyses and meta‐regression. The evidence certainty was evaluated using GRADE. RESULTS: This review included 25 original trials investigating the effect of a high (mostly 80%) versus a low (mostly 30%) FiO(2). Risk of bias was intermediate for all trials. A high FiO(2) did not result in a significant reduction in surgical site infections (OR: 0.91, 95% CI 0.81–1.02 [p = .10]). No effect was found for all other included outcomes, including mortality (OR = 1.27, 95% CI: 0.90–1.79 [p = .18]) and hospital length of stay (mean difference = 0.03 days, 95% CI −0.25 to 0.30 [p = .84). Results from subgroup analyses and meta‐regression did not identify any clear effect modifiers across outcomes. The certainty of evidence (GRADE) was rated as low for most outcomes. CONCLUSIONS: In adults undergoing general anesthesia for non‐cardiac surgery, a high FiO(2) did not improve outcomes including surgical site infections, length of stay, or mortality. However, the certainty of the evidence was assessed as low

    Goal-directed haemodynamic therapy during general anaesthesia for noncardiac surgery:a systematic review and meta-analysis

    Get PDF
    BACKGROUND: During general anaesthesia for noncardiac surgery, there remain knowledge gaps regarding the effect of goal-directed haemodynamic therapy on patient-centred outcomes. METHODS: Included clinical trials investigated goal-directed haemodynamic therapy during general anaesthesia in adults undergoing noncardiac surgery and reported at least one patient-centred postoperative outcome. PubMed and Embase were searched for relevant articles on March 8, 2021. Two investigators performed abstract screening, full-text review, data extraction, and bias assessment. The primary outcomes were mortality and hospital length of stay, whereas 15 postoperative complications were included based on availability. From a main pool of comparable trials, meta-analyses were performed on trials with homogenous outcome definitions. Certainty of evidence was evaluated using Grading of Recommendations, Assessment, Development, and Evaluations (GRADE). RESULTS: The main pool consisted of 76 trials with intermediate risk of bias for most outcomes. Overall, goal-directed haemodynamic therapy might reduce mortality (odds ratio=0.84; 95% confidence interval [CI], 0.64 to 1.09) and shorten length of stay (mean difference=–0.72 days; 95% CI, –1.10 to –0.35) but with low certainty in the evidence. For both outcomes, larger effects favouring goal-directed haemodynamic therapy were seen in abdominal surgery, very high-risk surgery, and using targets based on preload variation by the respiratory cycle. However, formal tests for subgroup differences were not statistically significant. Goal-directed haemodynamic therapy decreased risk of several postoperative outcomes, but only infectious outcomes and anastomotic leakage reached moderate certainty of evidence. CONCLUSIONS: Goal-directed haemodynamic therapy during general anaesthesia might decrease mortality, hospital length of stay, and several postoperative complications. Only infectious postoperative complications and anastomotic leakage reached moderate certainty in the evidence

    Unstable neurons underlie a stable learned behavior

    Get PDF
    Motor skills can be maintained for decades, but the biological basis of this memory persistence remains largely unknown. The zebra finch, for example, sings a highly stereotyped song that is stable for years, but it is not known whether the precise neural patterns underlying song are stable or shift from day to day. Here we demonstrate that the population of projection neurons coding for song in the premotor nucleus, HVC, change from day to day. The most dramatic shifts occur over intervals of sleep. In contrast to the transient participation of excitatory neurons, ensemble measurements dominated by inhibition persist unchanged even after damage to downstream motor nerves. These observations offer a principle of motor stability: spatiotemporal patterns of inhibition can maintain a stable scaffold for motor dynamics while the population of principal neurons that directly drive behavior shift from one day to the next
    corecore