9 research outputs found

    Salivary gland immunohistochemistry vs substantia nigra sonography: comparative analysis of diagnostic significance

    Get PDF
    Introduction. Parkinson's disease (PD) urges for new instrumental methods of diagnosis. Transcranial sonography of the substantia nigra (SN TCS) is an established method for early PD diagnosis but its application is limited. Recently, biopsies (primarily that of salivary gland) and test for abnormal -synuclein are suggested to verify PD. Materials and methods. We assessed 12 individuals with PD, HoehnYahr 2.3 0.4. The assessments included: UPDRS, NMSQ, NMSS, RBDSQ, PDQ-8, MoCA, and HADS scoring; SN TCS; and sublingual gland immunohistochemistry for phosphorylated -synuclein (PS-129) with automated morphometric analysis. Results. Substantia nigra hyperechogenicity was shown in 75% of patients whereas biopsy revealed PS-129 in 100% of patients. Echogenic area of the substantia nigra was 0.24 [0.21; 0.3] cm2. PS-129 inclusion area varied from 28.47 [27.55; 96.26] to 238.77 [234.13; 272.49] m2, and PS-129 proportion varied from 13.4% to 93.4% of the nervous fiber area across the patients. We found relations between PS-129 and NMSQ (r = 0.8; p 0.001), NMSS (r = 0.9; p 0.001), PDQ-8 (r = 0.7; p = 0.003), UPDRS-I (r = 0.7; p = 0.009), UPDRS-II (r = 0.6; p = 0.03), and HADS (anxiety r = 0.8; p = 0.002; depression r = 0.6; p = 0.04) scores. Conclusion. The results demonstrate a higher biopsy sensitivity as compared to SN TCS. Automated morphometric analysis has been newly applied to assess PS-129 occurrence. Immunohistochemistry results are directly related to non-motor symptom severity, which may indicate high probability of PS-129 presence and diagnosis confirmation in early disease

    Superconducting integrated submillimeter receiver for TELIS

    No full text
    In this report an overview of the results on the development of a single-chip superconducting integrated receiver for the Terahertz Limb Sounder (TELIS) balloon project intended to measure a variety of stratosphere trace gases is presented. The Superconducting Integrated Receiver (SIR) comprises in one chip a planar antenna integrated with a superconductor-insulator-superconductor (SIS) mixer, a superconducting Flux Flow Oscillator (FFO) acting as Local Oscillator (LO) and a second SIS harmonic mixer (HM) for FFO phase locking. As a result of the FFO design optimization a free-running linewidth between 9 and 1.5 MHz has been measured in the frequency range 500-710 GHz resulting in phase-locking of 35 to 95% of the FFO power correspondingly. A new generation of the SIR devices with improved FFO performance and optimized interface between FFO and SIS/HM has been developed and comprehensively tested. As a result all required TELIS parameters were demonstrated., Phase-locked FFO operation over entire SIR channel frequency range has been realized, spectral resolution below 1 MHz has been confirmed by gas cell and CW signal measurements. An uncorrected double side band (DSB) noise temperature below 250 K has been measured with the phase-locked FFO. The intermediate frequency bandwidth 4-8 GHz; has been realized. To ensure remote operation of the phase-locked SIR several procedures for its automatic computer control have been developed and tested

    Development and characterization of the superconducting integrated receiver channel of the TELIS atmospheric sounder

    No full text
    The balloon-borne instrument TELIS (TErahertz and submillimetre LImb Sounder) is a three-channel superconducting heterodyne spectrometer for atmospheric research use. It detects spectral emission lines of stratospheric trace gases that have their rotational transitions at THz frequencies. One of the channels is based on the superconducting integrated receiver (SIR) technology. We demonstrate for the first time the capabilities of the SIR technology for heterodyne spectroscopy in general, and atmospheric limb sounding in particular. We also show that the application of SIR technology is not limited to laboratory environments, but that it is well suited for remote operation under harsh environmental conditions. Within a SIR the main components needed for a superconducting heterodyne receiver such as a superconductor-insulator-superconductor (SIS) mixer with a quasi-optical antenna, a flux-flow oscillator (FFO) as the local oscillator, and a harmonic mixer to phase lock the FFO are integrated on a single chip. Light weight and low power consumption combined with broadband operation and nearly quantum limited sensitivity make the SIR a perfect candidate for use in future airborne and space-borne missions. The noise temperature of the SIR was measured to be as low as 120 K, with an intermediate frequency band of 4-8 GHz in double-sideband operation. The spectral resolution is well below 1 MHz, confirmed by our measurements. Remote control of the SIR under flight conditions has been demonstrated in a successful balloon flight in Kiruna, Sweden. The sensor and instrument design are presented, as well as the preliminary science results from the first flight

    Integrated SubmmWave Receiver: Development and Applications

    No full text
    A superconducting integrated receiver (SIR) comprises in a single chip a planar antenna combined with a superconductor-insulator-superconductor (SIS) mixer, a superconducting Flux Flow Oscillator (FFO) acting as a Local Oscillator (LO) and a second SIS harmonic mixer (HM) for the FFO phase locking. In this report, an overview of the SIR and FFO developments and optimizations is presented. Improving on the fully Nb-based SIR we have developed and studied Nb–AlN–NbN circuits, which exhibit an extended operation frequency range. Continuous tuning of the phase locked frequency has been experimentally demonstrated at any frequency in the range 350–750GHz. The FFO free-running linewidth has been measured between 1 and 5MHz, which allows to phase lock up to 97% of the emitted FFO power. The output power of the FFO is sufficient to pump the matched SIS mixer. Therefore, it is concluded that the Nb–AlN–NbN FFOs are mature enough for practical applications. These achievements enabled the development of a 480–650GHz integrated receiver for the atmospheric-research instrument TErahertz and submillimeter LImb Sounder (TELIS). This balloon-borne instrument is a three-channel superconducting heterodyne spectrometer for the detection of spectral emission lines of stratospheric trace gases that have their rotational transitions at THz frequencies. One of the channels is based on the SIR technology. We demonstrate for the first time the capabilities of the SIR technology for heterodyne spectroscopy in general, and atmospheric limb sounding in particular. We also show that the application of SIR technology is not limited to laboratory environments, but that it is well suited for remote operation under harsh environmental conditions. Light weight and low power consumption combined with broadband operation and nearly quantum limited sensitivity make the SIR a perfect candidate for future airborne and space-borne missions. The noise temperature of the SIR was measured to be as low as 120K in double sideband operation, with an intermediate frequency band of 4–8GHz. The spectral resolution is well below 1MHz, confirmed by our measurements. Remote control of the SIR under flight conditions has been demonstrated in a successful balloon flight in Kiruna, Sweden. Capability of the SIR for high-resolution spectroscopy has been successfully proven also in a laboratory environment by gas cell measurements. The possibility to use SIR devices for the medical analysis of exhaled air will be discussed. Many medically relevant gases have spectral lines in the sub-terahertz range and can be detected by an SIR-based spectrometer. The SIR can be considered as an operational device, ready for many applications
    corecore