28 research outputs found

    Remediation of petroleum contaminated soil by photo-Fenton process applying black, white and germicidal light

    Get PDF
    The aim of this work was to study the application of photo-Fenton process to remediate oil contaminated soil. In this work, the influence of irradiation time, hydrogen peroxide concentration and the use of visible, UV-A and UV-C light were investigated. In addition, the presence of external catalyst (Fe2+) was assessed. The photocatalytic treatment of petroleum contaminated soil was an efficient method for removing the total organic content, achieving about 50% of TOC removal at the end of the reaction time. The use of UV-A light promoted higher TOC removal than other irradiation sources, increasing 17 and 10% the TOC removal when compared to UV-C and visible light, respectively. In the case of treatment using UV lamps, the addition of external Fe was not necessary to achieve high levels of TOC removal

    Óleo produzido a partir de mamona irrigada com esgoto doméstico para produção de biodiesel

    Get PDF
    A mamoneira (Ricinus communis L.), é uma das oleaginosas selecionadas para o fornecimento de matéria-prima visando a produção de biodiesel, e possui uma relevante importância econômica e social para o Nordeste. Este trabalho objetivou avaliar, os aspectos produtivos da cultura da mamona irrigada com esgoto doméstico. O sistema foi composto de um reator UASB, uma lagoa anaeróbia, tanque de polimento e 4 drenos com a plantação da mamona. Foi obtida a redução de matéria orgânica 68% para DQO e 77% para DBO. Os sólidos suspensos no dreno 1 apresentaram uma média de 270,17 mg/L, enquanto que no dreno 4 chegou a 40,50 mg/L. Os valores do pH ficaram entre (6-9) para todos os drenos. O teor de óleo contido nas sementes foi analisado e obteve-se um rendimento de 46-70%. O óleo obtido foi caracterizado obtendo acidez de 0.0003 mg KOH/g, sendo classificada como do tipo 1, a densidade ficou na faixa de 0,940 g/cm3 e a viscosidade cinemática foi de 248,65 mPa.s. A análise cromatográfica identificou o ácido ricinoleico em maior quantidade com 79,9% na composição dos ácidos graxos. Os experimentos mostraram que o óleo de mamona possui um grande potencial para a produção de biodiesel

    Utilização do processamento digital de imagens no monitoramento de estações de tratamento de efluentes

    Get PDF
    Neste trabalho é proposto um procedimento para reconhecimento semi-automático das espécies de protozoários por análise de imagem. Este programa (ProtoRec v.2) foi em seguida utilizado para estudar a evolução da microfauna durante períodos de transição (paragem e arranque da estação). Os resultados obtidos foram satisfatórios em relação ao reconhecimento das espécies pelo programa e o acompanhamento da estação permitiu-nos verificar a degradação e envelhecimento da lama e o aparecimento de protozoários que evidenciam tal fato

    Endogenous iron as a photo-Fenton reaction catalyst for the degradation of Pah's in soils

    Get PDF
    Polycyclic aromatic hydrocarbon (PAH) components of diesel fuel are considered hazardous, due to their toxicity. We report the degradation of 16 PAHs using photo-Fenton and photo-Fenton-like processes in two different soil samples (S1 and S2) artificially contaminated with diesel oil. Experimental factorial designs were used to determine the most effective treatment conditions, with a view to achieving economical feasibility. For photo-Fenton reactions, the best degradation conditions resulted in an overall PAH concentration reduction of 94.6% and 95.6% for soils S1 and S2, respectively. The photo-Fenton-like processes also led to satisfactory degradation levels, obtained with only endogenous iron, low hydrogen peroxide concentration, short exposure time and no soil pH adjustment. These results demonstrate the viability of photo-Fenton-like processes to treat PAH contaminated areas.Hidrocarbonetos policíclicos aromáticos (HPA) estão presentes no óleo diesel, sendo considerados perigosos devido à sua toxicidade. Neste estudo relatamos a degradação de 16 HPA em dois solos diferentes (S1 e S2) contaminados artificialmente com óleo diesel, usando processos foto-Fenton e pseudo-foto-Fenton. Planejamentos fatoriais foram usados para obter condições de tratamento mais eficientes e econômicas. Para a reação foto-Fenton, as condições mais favoráveis resultaram 94,6% e 95,6% de degradação dos HPA para os solos S1 e S2, respectivamente. O processo pseudo-foto-Fenton também apresentou um nível satisfatório de degradação, obtido em condições econômicas, com ferro endógeno, baixa concentração de peróxido, curto tempo de exposição à radiação e sem ajuste do pH do solo. Os resultados demonstram a eficiência do processo pseudo-foto-Fenton para tratar áreas contaminadas por HPA.329336Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES

    EVALUATION OF EFFICIENCY OF ADVANCED OXIDATIVE PROCESS IN DEGRADATION OF 2-4 DICHLOROPHENOL EMPLOYING UV-C RADIATION REATOR

    Get PDF
    The study accomplished to analyze, identify and quantify 2,4-dichlorophenol employing high efficiency chromatography with a previously validated analytical methodology. The validation was made by using some analytical parameters: linearity, precision, accuracy, quantification limit (LOQ) and detection limit (LOD). The analytical curve was linear for the studied range of concentration (10 up to 100 mg.L-1) presenting a linear regression coefficient (R2) above 0,99. Regarding the methodology accuracy, a repeatability analysis was performed by observing a coefficient of variance (CV) below 20% for each of the concentrations used. The LOD and LOQ were adequate for the analyzed compound, showing the values of 1.42 mg.L-1 and 4.30 mg.L-1, respectively. The tests to verify the accuracy, by the recovery method provided values above 79%, thus resulting in specific, sensitive, precise, linear and accurate methodology in the studied concentration range. In the advanced oxidative process UV/H2O2, the compound was degraded to 88.04% under the following experimental conditions: [H2O2] = 1016.0 mg∙L-1 in 120 minutes. Therefore, it can be affirmed that the treatment employed can be used as an alternative for industrial effluent treatment with phenolic compounds.

    Degradação do contaminante emergente paracetamol empregando processos oxidativos avançados

    Get PDF
    Uma classe de poluentes tem sido investigada por pesquisadores de todo o mundo, estes são os contaminantes emergentes, que são considerados persistente e refratário. Estes compostos estão presentes em diferentes matrizes ambientais em baixas concentrações que requerem tratamentos alternativos de polimento capazes de promover a degradação destes poluentes, uma vez que os tratamentos convencionais não são capazes de removê-los. Este estudo avaliou a degradação do paracetamol utilizando processos oxidativos avançados (ação UV/H2O2 e foto-Fenton). Os resultados mostraram que o processo ação UV / H2O2 foi mais eficiente conseguindo promover a degradação de 99% do paracetamol, o que é corroborado pela estatística que mostraram que as experiências isentas da adição de ferro (UV / H2O2) foram os mais eficientes na degradação do paracetamol em solução aquosa solução. A metodologia para a identificação através de cromatografia foi validado de acordo exigência das agências existentes (INMETRO e ANVISA), assegurando a confiabilidade dos resultados
    corecore