557 research outputs found
Recommended from our members
In vitro quantification of lactate in Phosphate Buffer Saline (PBS) samples.
Continuous measurement of lactate levels in the blood is a prerequisite in intensive care patients who are susceptible to sepsis due to their suppressed immune system and increased metabolic demand. Currently, there exists no noninvasive tool for continuous measurement of lactate in clinical practice. The current mode of measurement is based on arterial blood gas analyzers which require sampling of arterial blood. In this work, we propose the use of Near Infra-Red (NIR) spectroscopy together with multivariate models as a means to non-invasively predict the concentration of lactate in the blood. As the first step towards this objective, we examined the possibility of accurately predicting concentrations of sodium lactate (NaLac) from the NIR spectra of 37 isotonic phosphate buffer saline (PBS) samples containing NaLac ranging from 0 to 20 mmol/L. NIR spectra of PBS samples were collected using the Lambda 1050 dual beam spectrometer over a spectral range of 800 - 2600 nm with a quartz cell of 1 mm optical path. Estimates and calibration of the lactate concentration with the NIR spectra were made using Partial Least-Squares (PLS) regression analysis and leave-one-out cross-validation on filtered spectra. The regression analysis showed a correlation coefficient of 0.977 and a standard error of 0.89 mmol/L between the predicted and prepared samples. The results suggest that NIR spectroscopy together with multivariate models can be a valuable tool for non-invasive assessment of blood lactate concentrations
Recommended from our members
Near Infrared Spectrometric Investigations on the behaviour of Lactate
In patients with life-threatening illnesses, the metabolic production and disposal of lactate are impaired, which leads to a build-up of blood lactate. In critical care units, the changes in lactate levels are measured through intermittent, invasive, blood sampling and in vitro assay. Continuous monitoring is lacking, yet such monitoring could allow early assessment of severity and prognosis to guide therapy. Currently, there is no routine means to measure lactate levels continuously, particularly non-invasively. The motivation of this study was to understand the interaction of lactate with light in the Near Infra Red (NIR) region of the electromagnetic spectrum. This was to create an opportunity to explore the possibility of a non-invasive sensing technology to monitor lactate continuously.
In vitro studies were performed using solution samples with varying concentration levels of sodium lactate in isotonic Phosphate Buffer Solution (PBS) at constant pH (7.4). These samples were prepared using stoichiometric solution compositions and spectra for each sample were taken using a state-of-the-art spectrometer in the NIR region. The spectra were then analysed qualitatively by 2D correlation analysis, which identified the regions of interest. Further analysis of these regions using linear regression at four randomly selected wavelengths showed bathochromic shifts, which, moreover, showed systematic variation correlating with lactate concentration
Recommended from our members
Comparison of a Genetic Algorithm Variable Selection and Interval Partial Least Squares for quantitative analysis of lactate in PBS
Blood lactate is an important biomarker that has been linked to morbidity and mortality of critically ill patients, acute ischemic stroke, septic shock, lung injuries, insulin resistance in diabetic patients, and cancer. Currently, the clinical measurement of blood lactate is done by collecting intermittent blood samples. Therefore, noninvasive, optical measurement of this significant biomarker would lead to a big leap in healthcare. This study, presents a quantitative analysis of the optical properties of lactate. The benefits of wavelength selection for the development of accurate, robust, and interpretable predictive models have been highlighted in the literature. Additionally, there is an obvious, time- and cost-saving benefit to focusing on narrower segments of the electromagnetic spectrum in practical applications. To this end, a dataset consisting of 47 spectra of Na-lactate and Phosphate Buffer Solution (PBS) was produced using a Fourier transform infrared spectrometer, and subsequently, a comparative study of the application of a genetic algorithm-based wavelength selection and two interval selection methods was carried out. The high accuracy of predictions using the developed models underlines the potential for optical measurement of lactate. Moreover, an interesting finding is the emergence of local features in the proposed genetic algorithm, while, unlike the investigated interval selection methods, no explicit constraints on the locality of features was imposed. Finally, the proposed genetic algorithm suggests the formation of α-hydroxy-esters methyl lactate in the solutions while the other investigated methods fail to indicate this
Recommended from our members
Investigations into the Effects of pH on Quantitative Measurements of Lactate in Biological Media Using ATR-FTIR Spectroscopy
Quantification of lactate/lactic acid in critical care environments is essential as lactate serves as an important biochemical marker for the adequacy of the haemodynamic circulation in shock and of cell respiration at the onset of sepsis/septic shock. Hence, in this study, ATR-FTIR was explored as a potential tool for lactate measurement, as the current techniques depend on sample preparation and fails to provide rapid response. Moreover, the effects of pH on PBS samples (7.4, 7, 6.5 and 6) and change in solution conditions (PBS to whole blood) on spectral features were also investigated. A total 189 spectra from five sets of lactate containing media were obtained. Results suggests that lactate could be measured with more than 90% accuracy in the wavenumber range of 1500-600 cm-1. The findings of this study further suggest that there exist no effects of change in pH or media, when estimating lactate concentration changes in this range of the Mid-IR spectral region
Recommended from our members
Near Infrared and Aquaphotomic analysis of water absorption in lactate containing media
Increased concentrations of lactate levels in blood are often seen in patients with life-threatening cellular hypoperfusion or infections. State-of-the-art techniques used in clinical practice for measuring serum lactate concentrations rely on intermittent blood sampling and do not permit continuous monitoring of this all important parameter in critical care environments.In recent years, Near Infrared (NIR) Spectroscopy has been established as a possible alternative to existing methods that can mitigate these constraints and be used for non-invasive continuous monitoring of lactate. Nevertheless, the dominant absorption of -OH overtone bands of water in the NIR presents a challenge and complicates the accurate detection of other absorbers such as lactate. For this reason, comprehensive analysis of the -OH overtone bands with systematic lactate concentration changes is essential. This paper reports on the analysis of NIR spectra of two aqueous systems of varying concentrations of lactate in saline and whole blood using the principles of Aquaphotomics.The results show distinctive conformational and structural differences in lactate-water binding, which arise due to the molecular interactions of bonds present in respective solvents
SARS-CoV-2: characterisation and mitigation of risks associated with aerosol generating procedures in dental practices.
Introduction The objectives were to characterise the particle size distribution of aerosols generated by standard dental aerosol generating procedures (AGPs) and to assess the impact of aerosol-management interventions on 'fallow time'. Interventions included combinations of high-volume intraoral suction (HVS[IO]), high-volume extraoral suction (HVS[EO]) and an air cleaning system (ACS).Method A sequence of six AGPs were performed on a phantom head. Real-time aerosol measurements (particle size range 0.0062-9.6 μm) were acquired from six locations within a typical dental treatment room (35 m3).Results The majority (>99%) of AGP particles were <0.3 μm diameter and remained at elevated levels around the dental team during the AGPs. With no active aerosol-management interventions, AGP particles were estimated to remain above the baseline range for up to 30 minutes from the end of the sequence of procedures.Conclusions The results emphasise the importance of personal protection equipment, particularly respiratory protection. Use of HVS(IO), either alone or in combination with the ACS, reduced particle concentrations to baseline levels on completion of AGPs. These data indicate potential to eliminate fallow time. The study was performed using a phantom head so confirmatory studies with patients are required
Recommended from our members
In-vivo quantification of lactate using Near Infrared reflectance spectroscopy
Elevated lactate levels in blood (hyperlactatemia) are indications of hypoperfusion or sepsis in critical care conditions. Quantification and monitoring of this important marker is performed using intermittent blood sampling, which fails to provide a complete scenario to aid clinicians in diagnosis. The feasibility of Near Infrared (NIR) Spectroscopy as an alternative to state-of-the-art techniques in critical care environments for non-invasive and continuous monitoring of lactate has previously been established. Nevertheless, the challenge lies in translating this research from bench to bedside monitoring. For this reason, a pilot investigation was carried out with a portable NIR spectrometer, where spectra in the range of 900-1300 nm were collected from 8 healthy human volunteers undertaking a high intensity incremental exercise protocol for lactate monitoring. This paper reports on the measurement set-up, spectra acquisition and analysis of diffuse NIR reflectance spectra of varying concentrations of lactate. The results obtained by 2D correlation analysis and linear regression are promising and show that the wavelengths 923 nm, 1047 nm, 1142 nm, 1233 nm, 1280 nm and 1330 nm are significant for lactate concentration determination in the NIR region. This provides the necessary confidence for using NIR sensor technology for lactate detection in critical care
Recommended from our members
In-vitro spectrometric analysis of hyperlactatemia and lactic acidosis in buffer relating to sepsis
The normal range for pH in the human body is 7.35-7.45. When pH falls below 7.3, it is considered as severe acidemia. Acidemia, together with increased blood lactate concentrations (hyperlactatemia) constitute a severe threat to life, which is often referred to as lactic acidosis. The feasibility of near infrared transmission/reflectance spectroscopy as a tool to determine lactate concentration levels and pH, independently, has been well established. However, the effects on spectral features arising from simultaneous variations in pH and lactate are not fully understood. Hence, this paper reports on a spectroscopic study of 37 different lactate concentrations that were prepared at three different pH levels (7.4, 7.0 and 6.5). Near infrared spectra were acquired in the range 800-2500 nm, and were later divided into four spectral ranges. Further investigations were carried out on various wavelengths within each spectral range and sample set. Furthermore, partial least squares regression with cross-validation was performed on all data sets. The results showed a clear interdependence and overlapping spectral behavior between blood lactate concentrations and pH. The findings from this study suggest that for an accurate estimation of blood lactate using this technique, the pH of the sample must be previously known
Enhanced antitumour immunity following neoadjuvant chemoradiotherapy mediates a favourable prognosis in women with resected pancreatic cancer
Background This study investigates sex disparities in clinical outcomes and tumour immune profiles in patients with pancreatic ductal adenocarcinoma (PDAC) who underwent upfront resection or resection preceded by gemcitabine-based neoadjuvant chemoradiotherapy (nCRT).Methods Patients originated from the PREOPANC randomised controlled trial. Upfront surgery was performed in 82 patients, and 66 received nCRT before resection. The impact of sex on overall survival (OS) was investigated using Cox proportional hazards models. The immunological landscape within the tumour microenvironment (TME) was mapped using transcriptomic and spatial proteomic profiling.Results The 5-year OS rate differed between the sexes following resection preceded by nCRT, with 43% for women compared with 22% for men. In multivariate analysis, the female sex was a favourable independent prognostic factor for OS only in the nCRT group (HR 0.19; 95% CI 0.07 to 0.52). Multivariate heterogeneous treatment effects analysis revealed a significant interaction between sex and treatment, implying increased nCRT efficacy among women with resected PDAC. The TME of women contained fewer protumoural CD163+MRC1+M2 macrophages than that of men after nCRT, as indicated by transcriptomic and validated using spatial proteomic profiling.Conclusion PDAC tumours of women are more sensitive to gemcitabine-based nCRT, resulting in longer OS after resection compared with men. This may be due to enhanced immunity impeding the infiltration of protumoral M2 macrophages into the TME. Our findings highlight the importance of considering sex disparities and mitigating immunosuppressive macrophage polarisation for personalised PDAC treatment
- …