13,521 research outputs found
Recommended from our members
Metaldehyde removal from drinking water by adsorption onto filtration media: mechanisms and optimisation
Trace micropollutants should be removed during drinking water production without increasing the disinfection-by-product formation potential or energy demand of the treatment process. We demonstrate the efficacy of different filtration media to remove metaldehyde through controlled batch experiments on water augmented with metaldehyde. Equilibrium concentrations of metaldehyde and surrogate organics were successfully described by the Freundlich isotherm. Metaldehyde can be attenuated to varying degrees with activated carbon and sand with an active and inactive biofilm with kf values ranging from 0.006–0.3 (mg g−1)(L mg−1)1/n. The presence of the active biofilm improved metaldehyde adsorption by sand media, due to additional biosorption mechanisms, a greater surface area or biodegradation. Baseline levels of competing natural organic matter surrogates (NOM) reduced overall adsorption efficacy but increasing concentrations of NOM did not impact metaldehyde removal efficacy in a significant way. Biological activated carbon was identified as the most suitable adsorbent of metaldehyde (94% removal) but sand with an acclimated biofilm was capable of acting as a bio-adsorbent of metaldehyde even under environmentally relevant concentrations (41% adsorption from 0.002.5 mg L−1). Moreover, we observed that thermal hydrolysis of metaldehyde occurred at 60 °C, suggesting that thermal regeneration of GAC for this pesticide was possible at relatively low temperatures. Biological adsorption and thermal hydrolysis approaches presented herein offered a way forward to increase efficiency and cost effectiveness of existing treatments for metaldehyde
Recommended from our members
Cavity Resonance Sensor with Disposable Analyte Container for Point of Care Testing
The use of phononic crystals and resonant structures as sensing platforms paves the way to the development of new biomedical technologies. An acoustic sensor with a resonant cavity and a disposable element was investigated in this paper. The sensor consists of seven layers with high acoustic impedance mismatch. The disposable element used was a glass spectrophotometry cuvette and, during the experimentation, it was filled with different liquid analytes showing characteristic transmission features that could be used as measures to differentiate and identify them. Experimental transmission curves were obtained using an electronic characterization system that uses a double sideband modulation technique to acquire valuable information about the structure being analyzed. Simulations using the 1-D transmission line method were performed to support the experimental realizations. The frequency of maximum transmission has been found to be strongly dependent on the speed of sound of the analyte under test
Recommended from our members
Fully-disposable multilayered phononic crystal liquid sensor with symmetry reduction and a resonant cavity
Phononic crystals are artificial structures with unique capabilities to control the transmission of acoustic waves. These novel periodic composite structures bring new possibilities for developing a fundamentally new sensor principle that combines features of both ultrasonic and resonant sensors. This paper reports the design, fabrication and evaluation of a phononic crystal sensor for biomedical applications, especially for its implementation in point of care testing technologies. The key feature of the sensor system is a fully-disposable multi-layered phononic crystal liquid sensor element with symmetry reduction and a resonant cavity. The phononic crystal structure consists of eleven layers with high acoustic impedance mismatch. A defect mode was utilized in order to generate a well-defined transmission peak inside the bandgap that can be used as a measure. The design of the structures has been optimized with simulations using a transmission line model. Experimental realizations were performed to evaluate the frequency response of the designed sensor using different liquid analytes. The frequency of the characteristic transmission peaks showed to be dependent on the properties of the analytes used in the experiments. Multi-layered phononic crystal sensors can be used in applications, like point of care testing, where the on-line measurement of small liquid samples is required
Analysis and correction of the magnetic field effects in the Hybrid Photo-Detectors of the RICH2 Ring Imaging Cherenkov detector of LHCb
The Ring Imaging Cherenkov detectors of the LHCb experiment at the Large
Hadron Collider at CERN are equipped with Hybrid Photo-Detectors. These vacuum
photo-detectors are affected by the stray magnetic field of the LHCb magnet,
which degrades their imaging properties. This effect increases the error on the
Cherenkov angle measurement and would reduce the particle identification
capabilities of LHCb. A system has been developed for the RICH2 Ring Imaging
Cherenkov detector to perform a detailed characterisation of the magnetic
distortion effects. It is described, along with the methods implemented to
correct for these effects, restoring the optimal resolution.Comment: 16 pages, 11 figure
Functional traits in macrophyte studies: Current trends and future research agenda
The use of functional traits (FTs) can provide quantitative information to explain macrophyte ecology more effectively than traditional taxonomic-based methods. This research aims to elucidate the trait-based approaches used in recent macrophyte studies to outline their applications, shortcomings, and future challenges. A systematic literature review focused on macrophytes and FTs was carried out on Scopus database (last accessed May 2020). The latest 520 papers published from 2010 to 2020, which represent 70 % of the whole literature selected since 1969, were carefully screened. Reviewed studies mainly investigated: 1) the role of FTs in shaping communities; 2) the responses of macrophytes to environmental gradients; 3) the application of FTs in monitoring anthropic pressures; and 4) the reasons for success of invasive species. Studied areas were concentrated in Europe (41 %) and Asia (32 %), overlooking other important biodiversity hotspots, and only 6.2 % of the world macrophytes species were investigated in dedicated single species studies. The FTs most commonly used include leaf economic and morphological traits, and we noticed a lack of attention on root traits and in general on spatial traits patterns, as well as a relatively poor understanding of how FTs mediate biotic interactions. High-throughput techniques, such as remote sensing, allow to map fine-scale variability of selected traits within and across systems, helping to clarify multiple links of FTs with ecological drivers and processes. We advise to promote investigations on root traits, and to push forward the integration of multiple approaches to better clarify the role of macrophytes at multiple scales
Improving signal stability in a multi-electrode array (MEA) system for cardiac biopsies
This work evaluates the performance of a microelectrode array (MEA) to be used in a specific platform dedicated for measuring field potentials of small human cardiac samples. A test bench has been developed to characterize the electrodes by measuring their impedance as well as to modify their characteristic curve using a replatinization process, where black platinum is deposited on the indicated areas of the MEA flex-pcb. This set-up consists of the array of microelectrodes made of gold, together with its corresponding electronic adapter board, a potentiostat and an electrochemical interface. Phosphate buffered saline (PBS), which is commonly considered for this type of analysis, has been used for impedance characterization. Initially, the impedance presents a highly variable behavior at different frequencies as well as between the different channels of the array. Once the platinization process has been carried out, the impedance in all the recording channels is very similar and has decreased over a large part of the frequency range under study. A complete electrical model of the electrodes has been proposed and analyzed, achieving better results by including the mathematical constant phase element (CPE) associated with capacitive behavior (model fitting error < 2%). Finally, the characterization of the different noise contributions has been carried out. Based on the obtained results, it can be concluded that the evaluated system allows the recording of field potential signals from small human cardiac tissues
Recommended from our members
Acoustic spectrometer: Resonant sensing platform for measuring volumetric properties of liquid samples
A sensing platform for measuring volumetric properties of liquid samples using phononic crystals is presented in this paper. The proposed sensor concept is based on the transmission of elastic and acoustic waves through solids and liquids respectively to gather relevant information about the properties of the liquid under test. A major difference between this concept and the majority of current resonant sensors, like the well-known quartz crystal microbalance, is that the acoustic spectrometer proposed measures bulk properties and not interfacial properties of the liquid. The sensing platform uses a disposable analyte container to facilitate the measurement of hazardous substances and enable its use in biomedical applications. An electronic characterization system based on the acquisition of three mixed signals was developed to obtain the frequency response of the designed sensor. Finally, experimental and theoretical realizations were performed, using different analytes and showing characteristic transmission features that can be used as measures to determine the physical value speed of sound
Frontiers of beam diagnostics in plasma accelerators: measuring the ultra-fast and ultra-cold
Advanced diagnostics are essential tools in the development of plasma-based accelerators. The accurate measurement of the quality of beams at the exit of the plasma channel is crucial to optimize the parameters of the plasma accelerator. 6D electron beam diagnostics will be reviewed with emphasis on emittance measurement, which is particularly complex due to large energy spread and divergence of the emerging beams, and on femtosecond bunch length measurements
- …