285 research outputs found

    Linearity of calibration curves: use and misuse of the correlation coefficient.

    Get PDF
    correlation coefficient is commonly used to evaluate the degree of linear association between two variables. However, it can be shown that a correlation coefficient very close to one might also be obtained for a clear curved relationship. Other statistical tests, like the Lack-of-fit and Mandel's fitting test thus appear more suitable for the validation of the linear calibration model. A number of cadmium calibration curves from atomic absorption spectroscopy were assessed for their linearity. All the investigated calibration curves were characterized by a high correlation coefficient (r >0.997) and low quality coefficient (QClinearity; goodness of fit; correlation coefficient; lack-of-fit; calibration; absorption;

    On the misuse of the correlation coefficient to assess linearity of calibration curves.

    Get PDF
    The correlation coefficient is commonly used to evaluate the degree of linear association between two variables. However, it can be shown that a correlation coefficient very close to one might also be obtained for a clearly curved relationship. Other statistical tests, like the Lack-of-fit and Mandel's fitting test appear therefore more suitable for the validation of the linear calibration model. A number of cadmium calibration curves from atomic absorption spectroscopy were assessed for their linearity. All the investigated calibration curves were characterised by a high correlation coefficient (r > 0.997) and low quality coefficient (QCEfficiency; Distribution; Variable; Value; Expected; Yield;

    Use of Tenax® films to demonstrate the migration of chemical contaminants from cardboard into dry food

    Get PDF
    Contaminants in food packaging are a challenge of our time since the packaging material itself has been found to represent a source of food contamination through the migration of substances from it. Before first use, packaging materials destined for the packaging of dry foods can be evaluated by performing migration experiments with the simulant for dry foods, Tenax (R). This simulant is commercially available as a powder that is more difficult to handle during the migration experiments. This paper reports the development of a Tenax film. The film can be applied to the cardboard surface to conduct the migration test. After the migration is completed, the film can be easily extracted to determine the concentration of the contaminants in the film. Finally, the performance of the Tenax film was compared with the conventional Tenax powder for the evaluation of 15 model migrants

    Short-term health effects in the general population following a major train accident with acrylonitrile in Belgium

    Get PDF
    Background: Following a train derailment, several tons of acrylonitrile (ACN) exploded, inflamed and part of the ACN ended up in the sewage system of the village of Wetteren. More than 2000 residents living in the close vicinity of the accident and along the sewage system were evacuated. A human biomonitoring study of the adduct N-2-cyanoethylvaline (CEV) was carried out days 14-21 after the accident. Objectives: (1) To describe the short-term health effects that were reported by the evacuated residents following the train accident, and (2) to explore the association between the CEV concentrations, extrapolated at the time of the accident, and the self-reported short-term health effects. Methods: Short-term health effects were reported in a questionnaire (n=191). An omnibus test of independence was used to investigate the association between the CEV concentrations and the symptoms. Dose-response relationships were quantified by Generalized Additive Models (GAMs). Results: The most frequently reported symptoms were local symptoms of irritation. In non-smokers, dose-dependency was observed between the CEV levels and the self-reporting of irritation (p=0.007) and nausea (p=0.007). Almost all non-smokers with CEV concentrations above 100 pmol/g globin reported irritation symptoms. Both absence and presence of symptoms was reported by non-smokers with CEV concentrations below the reference value and up to 10 times the reference value. Residents who visited the emergency services reported more symptoms. This trend was seen for the whole range of CEV concentrations, and thus independently of the dose. Discussion and conclusion: The present study is one of the first to relate exposure levels to a chemical released during a chemical incident to short-term (self-reported) health effects. A dose-response relation was observed between the CEV concentrations and the reporting of short-term health effects in the non-smokers. Overall, the value of self-reported symptoms to assess exposure showed to be limited. The results of this study confirm that a critical view should be taken when considering self-reported health complaints and that ideally biomarkers are monitored to allow an objective assessment of exposure

    Dioxins in Food and Feed - Reference Methods and New Certified Reference Materials (DIFFERENCE)

    Get PDF
    The European research project DIFFERENCE (“Dioxins in Food and Feed – Reference methods and New Certified Reference Materials”) was focussed on the development of an alternative methods for analysis of polychlorinated dibenzodioxins (PCDDs), dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) using comprehensive multi-dimensional gas chromatography (GC×GC), gas chromatography combined with low resolution ion-trap mass spectrometry (GCLRMS/ MS), the CALUX bioassay and an Ah-PCR technique. GC combined with high resolution mass spectrometry (HRMS) was used as a reference method in all comparisons

    Polychlorinated dibenzo-p-dioxins, dibenzofurans and biphenyls in fish from the Netherlands: concentrations, profiles and comparison with DR CALUX® bioassay results

    Get PDF
    Fish from Dutch markets were analysed for concentrations of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) and compared with the new European maximum residue levels (MRLs), set in 2006. In a first study on 11 different fish and shellfish from various locations, concentrations of PCDD/Fs were nearly all below the MRL for PCDD/Fs [4 pg toxic equivalents (TEQ) per gram wet weight (ww)] and nearly all below 8 pg total TEQ/g ww, the new MRL for the sum of PCDD/Fs and DL-PCBs. Some samples exceeded the total TEQ MRL, such as anchovy, tuna and sea bass. Furthermore, 20 (out of 39) wild eel samples exceeded the specific MRL for eel (12 pg total TEQ/g ww), as the study revealed PCDD/F TEQ levels of 0.2-7.9 pg TEQ/g ww and total TEQ values of 0.9 to 52 pg/g ww. TEQ levels in farmed and imported eel were lower and complied with the MRLs. Smoking eel, a popular tradition in the Netherlands, only had marginal effects on PCDD/F and DL-PCB concentrations. Owing to volatilization, concentrations of lower-chlorinated PCBs were reduced to below the limit of quantification after smoking. DL-PCBs contributed 61-97% to the total TEQ in all eel samples. This also holds for other fish and shellfish (except shrimps): DL-PCB contributed (on average) from 53 (herring) to 83% (tuna) to the total TEQ. Principal-component analysis revealed distinctive congener profiles for PCDD/Fs and non-ortho PCBs for mussels, pikeperch, herring and various Mediterranean fish. The application of new TCDD toxic equivalency factors (TEFs) set by the World Health Organization in 2006 (to replace the 1997 TEFs) resulted in lower TEQ values, mainly owing to a decreased mono-ortho PCB contribution. This decrease is most pronounced for eel, owing to the relative high mono-ortho PCB concentrations in eel. Consequently, a larger number of samples would comply with the MRLs when the new TEFs are applied. The DR CALUX (R) assay may be used for screening total TEQ levels in eel, in combination with gas chromatography-high resolution mass spectrometry confirmation of suspected samples. An almost 1:1 correlation was found when the 1997 TEFs were applied, but, surprisingly, a 1.4-fold overestimation occurred with application of the 2006 TEFs
    • …
    corecore