4,042 research outputs found

    Capacity formulas in MWPC: some critical reflexions

    Get PDF
    An approximate analytical expression for "capacitance" of MWPC configurations circulates in the literature since decades and is copied over and over again. In this paper we will try to show that this formula corresponds to a physical quantity that is different from what it is usually thought to stand for

    Study of a high spatial resolution 10B-based thermal neutron detector for application in neutron reflectometry: the Multi-Blade prototype

    Full text link
    Although for large area detectors it is crucial to find an alternative to detect thermal neutrons because of the 3He shortage, this is not the case for small area detectors. Neutron scattering science is still growing its instruments' power and the neutron flux a detector must tolerate is increasing. For small area detectors the main effort is to expand the detectors' performances. At Institut Laue-Langevin (ILL) we developed the Multi-Blade detector which wants to increase the spatial resolution of 3He-based detectors for high flux applications. We developed a high spatial resolution prototype suitable for neutron reflectometry instruments. It exploits solid 10B-films employed in a proportional gas chamber. Two prototypes have been constructed at ILL and the results obtained on our monochromatic test beam line are presented here

    Quantitative Study of Magnetotransport through a (Ga,Mn)As Single Ferromagnetic Domain

    Full text link
    We have performed a systematic investigation of the longitudinal and transverse magnetoresistance of a single ferromagnetic domain in (Ga,Mn)As. We find that, by taking into account the intrinsic dependence of the resistivity on the magnetic induction, an excellent agreement between experimental results and theoretical expectations is obtained. Our findings provide a detailed and fully quantitative validation of the theoretical description of magnetotransport through a single ferromagnetic domain. Our analysis furthermore indicates the relevance of magneto-impurity scattering as a mechanism for magnetoresistance in (Ga,Mn)As.Comment: 5 pages, 4 figures; v2: missing references included, figures recompressed to improve readabilit

    Watergoot als intern transportsysteem voor tomaten

    Get PDF

    Hole spin polarization in GaAlAs:Mn structures

    Full text link
    A self-consistent calculation of the electronic properties of GaAlAs:Mn magnetic semiconductor quantum well structures is performed including the Hartree term and the sp-d exchange interaction with the Mn magnetic moments. The spin polarization density is obtained for several structure configurations. Available experimental results are compared with theory.Comment: 4 page

    Theory of Diluted Magnetic Semiconductor Ferromagnetism

    Full text link
    We present a theory of carrier-induced ferromagnetism in diluted magnetic semiconductors (III_{1-x} Mn_x V) which allows for arbitrary itinerant-carrier spin polarization and dynamic correlations. Both ingredients are essential in identifying the system's elementary excitations and describing their properties. We find a branch of collective modes, in addition to the spin waves and Stoner continuum which occur in metallic ferromagnets, and predict that the low-temperature spin stiffness is independent of the strength of the exchange coupling between magnetic ions and itinerant carriers. We discuss the temperature dependence of the magnetization and the heat capacity

    Some Restrictions Abroad Affecting Corporations

    Get PDF
    A neutron detector concept based on solid layers of boron carbide enriched in 1 B has been in development for the last few years as an alternative for He-3 by collaboration between the ILL, ESS and Linkoping University. This Multi-Grid detector uses layers of aluminum substrates coated with (B4C)-B-10 on both sides that are traversed by the incoming neutrons. Detection is achieved using a gas counter readout principle. By segmenting the substrate and using multiple anode wires, the detector is made inherently position sensitive. This development is aimed primarily at neutron scattering instruments with large detector areas, such as time-of-flight chopper spectrometers. The most recent prototype has been built to be interchangeable with the He-3 detectors of IN6 at ILL. The 1 B detector has an active area of 32 x 48 cm(2). It was installed at the IN6 instrument and operated for several weeks, collecting data in parallel with the regularly scheduled experiments, thus providing the first side-by-side comparison with the conventional He-3 detectors. Results include an efficiency comparison, assessment of the in-detector scattering contribution, sensitivity to gamma-rays and the signal-to-noise ratio in time-of-flight spectra. The good expected performance has been confirmed with the exception of an unexpected background count rate. This has been identified as natural alpha activity in aluminum. New convertor substrates are under study to eliminate this source of background

    Invloed zaadzetting op houdbaarheid van tomaten

    Get PDF

    Relatie diameter en gewicht bij vlezige tomaten

    Get PDF
    corecore