135 research outputs found
A comparative morphometric study of the myocardium during the postnatal development in normotensive and spontaneously hypertensive rats
Background: Differences in the size of cardiac muscle cells observed in normal and hypertrophic hearts have been assessed through different methodologies. Spontaneously hypertensive rats are often used as an experimental model of essential hypertension in humans, which allows researchers to study the relation between hypertension and cardiac hypertrophy. It has been shown that ventricular hypertrophy in mammals progresses and ventricular failure develops in the end stage of hypertrophy. The aim of the present study was to analyse a number of morphometric markers and compare them between male normotensive Wistar rats (WR) and male spontaneously hypertensive rats (SHR).
Materials and methods: The total number of male WR was 15, distributed in five age groups, each containing three animals: 2-week-old; 1-month-old; 3-month-old; 6-month-old; 12-month-old. The male SHR were distributed in two age groups, each containing three animals: 1-month-old (young) and 6-month-old (adult).
Results: As aging progressed, both in male normotensive WR and in male SHR we noted a statistically significant increase in the morphometric parameters thickness of the free wall and the cross-sectional area of the cardiomyocytes and their nuclei and a decrease in the cardiomyocytic density in both ventricles. These changes were more pronounced and occurred at an earlier age in SHR.
Conclusions: The present study analyses in detail the alterations in the myocardium of the left and right ventricle, initiated by age-related hypertrophy, as well as hypertrophy induced by arterial hypertension. (Folia Morphol 2018; 77, 2: 253–265
Superplastic deformation behaviour and microstructure evolution of near-α Ti-Al-Mn alloy
Superplastic deformation behaviour of conventional sheets of a near-α titanium alloy (Ti-2.5Al-1.8Mn) was studied by a step-by-step decrease of the strain rate and constant strain rate tests in a temperature range of 790–915 °C. The research found that superplastic deformation is possible in a temperature range of 815–890 °С and a constant strain rate range of 2 × 10−4 to 1 × 10−3 s−1 with elongation above 300% and m-index above 0.4. Also, the research identified the optimum superplastic temperature range of 815–850 °C and constant strain rate of 4 × 10−4 s−1 which provide a maximum elongation of 600–650%. Strain hardening is accelerated by dynamic grain growth at high temperatures of 865 and 890 °С. High dislocation activity is observed at superplastic flow in α-phase. Constitutive modelling of superplastic deformation behaviour is performed, and possible deformation mechanisms are discussed. It is suggested that grain boundary sliding between the α-grains is accommodated by a dislocation slip/creep mechanism
Measurement of and between 3.12 and 3.72 GeV at the KEDR detector
Using the KEDR detector at the VEPP-4M collider, we have measured
the values of and at seven points of the center-of-mass
energy between 3.12 and 3.72 GeV. The total achieved accuracy is about or
better than at most of energy points with a systematic uncertainty of
about . At the moment it is the most accurate measurement of in
this energy range
New precise determination of the \tau lepton mass at KEDR detector
The status of the experiment on the precise lepton mass measurement
running at the VEPP-4M collider with the KEDR detector is reported. The mass
value is evaluated from the cross section behaviour around the
production threshold. The preliminary result based on 6.7 pb of data is
MeV. Using 0.8 pb of data
collected at the peak the preliminary result is also obtained:
eV.Comment: 6 pages, 8 figures; The 9th International Workshop on Tau-Lepton
Physics, Tau0
Search for narrow resonances in e+ e- annihilation between 1.85 and 3.1 GeV with the KEDR Detector
We report results of a search for narrow resonances in e+ e- annihilation at
center-of-mass energies between 1.85 and 3.1 GeV performed with the KEDR
detector at the VEPP-4M e+ e- collider. The upper limit on the leptonic width
of a narrow resonance Gamma(R -> ee) Br(R -> hadr) < 120 eV has been obtained
(at 90 % C.L.)
Measurement of \Gamma_{ee}(J/\psi)*Br(J/\psi->e^+e^-) and \Gamma_{ee}(J/\psi)*Br(J/\psi->\mu^+\mu^-)
The products of the electron width of the J/\psi meson and the branching
fraction of its decays to the lepton pairs were measured using data from the
KEDR experiment at the VEPP-4M electron-positron collider. The results are
\Gamma_{ee}(J/\psi)*Br(J/\psi->e^+e^-)=(0.3323\pm0.0064\pm0.0048) keV,
\Gamma_{ee}(J/\psi)*Br(J/\psi->\mu^+\mu^-)=(0.3318\pm0.0052\pm0.0063) keV.
Their combinations
\Gamma_{ee}\times(\Gamma_{ee}+\Gamma_{\mu\mu})/\Gamma=(0.6641\pm0.0082\pm0.0100)
keV,
\Gamma_{ee}/\Gamma_{\mu\mu}=1.002\pm0.021\pm0.013 can be used to improve
theaccuracy of the leptonic and full widths and test leptonic universality.
Assuming e\mu universality and using the world average value of the lepton
branching fraction, we also determine the leptonic \Gamma_{ll}=5.59\pm0.12 keV
and total \Gamma=94.1\pm2.7 keV widths of the J/\psi meson.Comment: 7 pages, 6 figure
Measurement of main parameters of the \psi(2S) resonance
A high-precision determination of the main parameters of the \psi(2S)
resonance has been performed with the KEDR detector at the VEPP-4M e^{+}e^{-}
collider in three scans of the \psi(2S) -- \psi(3770) energy range. Fitting the
energy dependence of the multihadron cross section in the vicinity of the
\psi(2S) we obtained the mass value
M = 3686.114 +- 0.007 +- 0.011 ^{+0.002}_{-0.012} MeV and the product of the
electron partial width by the branching fraction into hadrons \Gamma_{ee}*B_{h}
= 2.233 +- 0.015 +- 0.037 +- 0.020 keV.
The third error quoted is an estimate of the model dependence of the result
due to assumptions on the interference effects in the cross section of the
single-photon e^{+}e^{-} annihilation to hadrons explicitly considered in this
work.
Implicitly, the same assumptions were employed to obtain the charmonium
leptonic width and the absolute branching fractions in many experiments.
Using the result presented and the world average values of the electron and
hadron branching fractions, one obtains the electron partial width and the
total width of the \psi(2S):
\Gamma_{ee} =2.282 +- 0.015 +- 0.038 +- 0.021 keV,
\Gamma = 296 +- 2 +- 8 +- 3 keV.
These results are consistent with and more than two times more precise than
any of the previous experiments
On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection
A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)
Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET
The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR
- …