402 research outputs found
Energy and operating cost analysis of the smart-scaled flow route directly to adipic acid
Abstract only
Investigating the Effect of Emoji in Opinion Classification of Uzbek Movie Review Comments
Opinion mining on social media posts has become more and more popular. Users
often express their opinion on a topic not only with words but they also use
image symbols such as emoticons and emoji. In this paper, we investigate the
effect of emoji-based features in opinion classification of Uzbek texts, and
more specifically movie review comments from YouTube. Several classification
algorithms are tested, and feature ranking is performed to evaluate the
discriminative ability of the emoji-based features.Comment: 10 pages, 1 figure, 3 table
Defects and glassy dynamics in solid He-4: Perspectives and current status
We review the anomalous behavior of solid He-4 at low temperatures with
particular attention to the role of structural defects present in solid. The
discussion centers around the possible role of two level systems and structural
glassy components for inducing the observed anomalies. We propose that the
origin of glassy behavior is due to the dynamics of defects like dislocations
formed in He-4. Within the developed framework of glassy components in a solid,
we give a summary of the results and predictions for the effects that cover the
mechanical, thermodynamic, viscoelastic, and electro-elastic contributions of
the glassy response of solid He-4. Our proposed glass model for solid He-4 has
several implications: (1) The anomalous properties of He-4 can be accounted for
by allowing defects to freeze out at lowest temperatures. The dynamics of solid
He-4 is governed by glasslike (glassy) relaxation processes and the
distribution of relaxation times varies significantly between different
torsional oscillator, shear modulus, and dielectric function experiments. (2)
Any defect freeze-out will be accompanied by thermodynamic signatures
consistent with entropy contributions from defects. It follows that such
entropy contribution is much smaller than the required superfluid fraction, yet
it is sufficient to account for excess entropy at lowest temperatures. (3) We
predict a Cole-Cole type relation between the real and imaginary part of the
response functions for rotational and planar shear that is occurring due to the
dynamics of defects. Similar results apply for other response functions. (4)
Using the framework of glassy dynamics, we predict low-frequency yet to be
measured electro-elastic features in defect rich He-4 crystals. These
predictions allow one to directly test the ideas and very presence of glassy
contributions in He-4.Comment: 33 pages, 13 figure
An interesting journey of an ingested needle: a case report and review of the literature on extra-abdominal migration of ingested Foreign bodies
Swallowed foreign bodies encounter a major problem especially in children, but fortunately they mostly do not cause any related complication and are easily passed with the stool. In this paper, an interesting journey of a needle is presented. A 20-year old female admitted to our emergency service after she had swallowed a sewing machine needle, which is initially observed in the stomach in the plain abdominal radiography. During the follow-up period, the needle traveled through bowels, and surprisingly was observed in the left lung on 10th day of the follow-up. It was removed with a thoracotomy and pneumotomy under the fluoroscopic guidance. The postoperative period was uneventful and the patient was discharged from the hospital on the day 5. We also review the literature on interesting extra-abdominal migrations of swallowing foreign bodies
X-Ray Repair Cross-Complementing Group 1 (XRCC1) Genetic Polymorphisms and Risk of Childhood Acute Lymphoblastic Leukemia: A Meta-Analysis
Background: Recently, there have been a number of studies on the association between XRCC1 polymorphisms and childhood acute lymphoblastic leukemia (ALL) risk. However, the results of previous reports are inconsistent. Thus, we performed a meta-analysis to clarify the effects of XRCC1 variants on childhood ALL risk. Methods: A meta-analysis was performed to examine the association between XRCC1 polymorphisms (Arg399Gln, Arg194Trp, and Arg280His) and childhood ALL risk. We critically reviewed 7 studies with a total of 880 cases and 1311 controls for Arg399Gln polymorphism, 3 studies with a total of 345 cases and 554 controls for Arg280His polymorphism, and 6 studies with a total of 783 cases and 1180 controls for Arg194Trp polymorphism, respectively. Odds ratio (OR) and its 95% confidence interval (CI) were used. Results: Significant association between XRCC1 Arg399Gln polymorphism and childhood ALL risk was observed in total population analyses (OR additive model = 1.501, 95 % CI 1.112–2.026, P OR = 0.008; OR dominant model = 1.316, 95 % CI = 1.104–1.569, POR = 0.002) and Asian subgroup analyses (ORadditive model = 2.338, 95%CI = 1.254–4.359, POR = 0.008; ORdominant model = 2.108, 95%CI = 1.498–2.967, POR = 0.000). No association was detected in Caucasians, Metizo and mixed populations. Ethnicity was considered as a significant source of heterogeneity in the meta-regression model. For the other two XRCC1 polymorphisms, no association with childhood ALL risk was found
The United States of America and Scientific Research
To gauge the current commitment to scientific research in the United States of America (US), we compared federal research funding (FRF) with the US gross domestic product (GDP) and industry research spending during the past six decades. In order to address the recent globalization of scientific research, we also focused on four key indicators of research activities: research and development (R&D) funding, total science and engineering doctoral degrees, patents, and scientific publications. We compared these indicators across three major population and economic regions: the US, the European Union (EU) and the People's Republic of China (China) over the past decade. We discovered a number of interesting trends with direct relevance for science policy. The level of US FRF has varied between 0.2% and 0.6% of the GDP during the last six decades. Since the 1960s, the US FRF contribution has fallen from twice that of industrial research funding to roughly equal. Also, in the last two decades, the portion of the US government R&D spending devoted to research has increased. Although well below the US and the EU in overall funding, the current growth rate for R&D funding in China greatly exceeds that of both. Finally, the EU currently produces more science and engineering doctoral graduates and scientific publications than the US in absolute terms, but not per capita. This study's aim is to facilitate a serious discussion of key questions by the research community and federal policy makers. In particular, our results raise two questions with respect to: a) the increasing globalization of science: “What role is the US playing now, and what role will it play in the future of international science?”; and b) the ability to produce beneficial innovations for society: “How will the US continue to foster its strengths?
How reliable is assessment of true vocal cord-arytenoid unit mobility in patients affected by laryngeal cancer? a multi-institutional study on 366 patients from the ARYFIX collaborative group
Purpose: In clinical practice the assessment of the “vocal cord-arytenoid unit” (VCAU) mobility is crucial in the staging, prognosis, and choice of treatment of laryngeal squamous cell carcinoma (LSCC). The aim of the present study was to measure repeatability and reliability of clinical assessment of VCAU mobility and radiologic analysis of posterior laryngeal extension. Methods: In this multi-institutional retrospective study, patients with LSCC-induced impairment of VCAU mobility who received curative treatment were included; pre-treatment endoscopy and contrast-enhanced imaging were collected and evaluated by raters. According to their evaluations, concordance, number of assigned categories, and inter- and intra-rater agreement were calculated. Results: Twenty-two otorhinolaryngologists evaluated 366 videolaryngoscopies (total evaluations: 2170) and 6 radiologists evaluated 237 imaging studies (total evaluations: 477). The concordance of clinical rating was excellent in only 22.7% of cases. Overall, inter- and intra-rater agreement was weak. Supraglottic cancers and transoral endoscopy were associated with the lowest inter-observer reliability values. Radiologic inter-rater agreement was low and did not vary with imaging technique. Intra-rater reliability of radiologic evaluation was optimal. Conclusions: The current methods to assess VCAU mobility and posterior extension of LSCC are flawed by weak inter-observer agreement and reliability. Radiologic evaluation was characterized by very high intra-rater agreement, but weak inter-observer reliability. The relevance of VCAU mobility assessment in laryngeal oncology should be re-weighted. Patients affected by LSCC requiring imaging should be referred to dedicated radiologists with experience in head and neck oncology
How reliable is assessment of true vocal cord-arytenoid unit mobility in patients affected by laryngeal cancer? a multi-institutional study on 366 patients from the ARYFIX collaborative group
Purpose: In clinical practice the assessment of the "vocal cord-arytenoid unit" (VCAU) mobility is crucial in the staging, prognosis, and choice of treatment of laryngeal squamous cell carcinoma (LSCC). The aim of the present study was to measure repeatability and reliability of clinical assessment of VCAU mobility and radiologic analysis of posterior laryngeal extension. Methods: In this multi-institutional retrospective study, patients with LSCC-induced impairment of VCAU mobility who received curative treatment were included; pre-treatment endoscopy and contrast-enhanced imaging were collected and evaluated by raters. According to their evaluations, concordance, number of assigned categories, and inter- and intra-rater agreement were calculated. Results: Twenty-two otorhinolaryngologists evaluated 366 videolaryngoscopies (total evaluations: 2170) and 6 radiologists evaluated 237 imaging studies (total evaluations: 477). The concordance of clinical rating was excellent in only 22.7% of cases. Overall, inter- and intra-rater agreement was weak. Supraglottic cancers and transoral endoscopy were associated with the lowest inter-observer reliability values. Radiologic inter-rater agreement was low and did not vary with imaging technique. Intra-rater reliability of radiologic evaluation was optimal. Conclusions: The current methods to assess VCAU mobility and posterior extension of LSCC are flawed by weak inter-observer agreement and reliability. Radiologic evaluation was characterized by very high intra-rater agreement, but weak inter-observer reliability. The relevance of VCAU mobility assessment in laryngeal oncology should be re-weighted. Patients affected by LSCC requiring imaging should be referred to dedicated radiologists with experience in head and neck oncology
- …