112 research outputs found

    A Composite Metric for Benchmarking Site Performance in TAVR: Results from the STS/ACC TVT Registry

    Get PDF
    Background: Transcatheter aortic valve replacement (TAVR) is a transformative therapy for aortic stenosis. Despite rapid improvements in technology and techniques, serious complications remain relatively common and are not well described by single outcome measures. The purpose of this study was to determine if there is site-level variation in TAVR outcomes in the United States using a novel 30-day composite measure. Methods: We performed a retrospective cohort study using data from the STS/ACC TVT Registry to develop a novel ranked composite performance measure that incorporates mortality and serious complications. The selection and rank order of the complications for the composite was determined by their adjusted association with 1-year outcomes. Sites whose risk-adjusted outcomes were significantly more or less frequent than the national average based on a 95% probability interval were classified as performing worse or better than expected. Results: The development cohort consisted of 52,561 patients who underwent TAVR between January 1, 2015 and December 31, 2017. Based on the associations with 1-year risk-adjusted mortality and health status, we identified four periprocedural complications to include in the composite risk model in addition to mortality. Ranked empirically according to severity, these included stroke, major, life-threatening or disabling bleeding, stage III acute kidney injury, and moderate or severe peri-valvular regurgitation. Based on these ranked outcomes, we found that there was significant site-level variation in quality of care in TAVR in the United States. Overall, better than expected site performance was observed in 25/301 (8%) of sites; performance as expected was observed in 242/301 sites (80%); and worse than expected performance was observed in 34/301 (11%) of sites. Thirty-day mortality, stroke, major, life-threatening or disabling bleeding, and moderate or severe peri-valvular leak were each substantially more common in sites with worse than expected performance as compared with other sites. There was good aggregate reliability of the model. Conclusions: There are substantial variations in the quality of TAVR care received in the United States, and 11% of sites were identified as providing care below the average level of performance. Further study is necessary to determine structural, process-related, and technical factors associated with high- and low-performing sites

    Antithrombotic drug removal from whole blood using Haemoadsorption with a porous polymer bead sorbent

    Get PDF
    Aim To evaluate the ability of the DrugSorb™-AntiThrombotic Removal (ATR) haemoadsorption device utilizing porous polymer bead sorbent technology to remove three commonly used antithrombotic drugs from whole blood. Methods and results We evaluated the removal of apixaban, rivaroxaban, and ticagrelor by the DrugSorb-ATR haemoadsorption device in a benchtop clinical scale model using bovine whole blood. Blood spiked at clinically relevant concentrations of an antithrombotic agent was continuously circulated through a 300-mL DrugSorb-ATR haemoadsorption device at a flow rate of 300 mL/min. Drug concentration was monitored over 6 h to evaluate drug removal. Results were compared with a control circuit without the haemoadsorption device. Removal rates at 30, 60, 120, and 360 minutes were: apixaban: 81.5%, 96.3%, 99.3% >99.8%; rivaroxaban: 80.7%, 95.1%, 98.9%, >99.5%; ticagrelor: 62.5%; 75%, 86.6%, >95% (all P <0.0001 vs. control). Blood pH and haematological parameters were not significantly affected by the DrugSorb-ATR haemoadsorption device when compared with the control circuit. Conclusion DrugSorb-ATR efficiently removes apixaban, rivaroxaban, and ticagrelor in a clinical-scale benchtop recirculation circuit with the bulk of removal occurring in the first 60 minutes. The clinical implications of these findings are currently investigated in patients undergoing on-pump cardiothoracic surgery in two US pivotal trials (ClinicalTrials.gov Identifiers: NCT04976530 and NCT05093504)

    One year follow-up of the multi-centre European PARTNER transcatheter heart valve study

    Get PDF
    BackgroundTranscatheter aortic valve implantation (TAVI) has emerged as a new therapeutic option in high-risk patients with severe aortic stenosis.AimsPARTNER EU is the first study to evaluate prospectively the procedural and mid-term outcomes of transfemoral (TF) or transapical (TA) implantation of the Edwards SAPIEN® valve involving a multi-disciplinary approach.Methods and resultsPrimary safety endpoints were 30 days and 6 months mortality. Primary efficacy endpoints were haemodynamic and functional improvement at 12 months. One hundred and thirty patients (61 TF, 69 TA), aged 82.1 ± 5.5 years were included. TA patients had higher logistic EuroSCORE (33.8 vs. 25.7, P <0.0005) and more peripheral disease (49.3 vs. 16.4, P< 0.0001). Procedures were aborted in four TA (5.8) and six TF cases (9.8). Valve implantation was successful in the remaining patients in 95.4 and 96.4, respectively. Thirty days and 6 months survival were 81.2 and 58.0 (TA) and 91.8 and 90.2 (TF). In both groups, mean aortic gradient decreased from 46.9 ± 18.1 to 10.9 ± 5.4 mmHg 6 months post-TAVI. In total, 78.1 and 84.8 of patients experienced significant improvement in New York Heart Association (NYHA) class, whereas 73.9 and 72.7 had improved Kansas City Cardiomyopathy Questionnaire (KCCQ) scores in TA and TF cohorts, respectively.ConclusionThis first team-based multi-centre European TAVI registry shows promising results in high-risk patients treated by TF or TA delivery. Survival rates differ significantly between TF and TA groups and probably reflect the higher risk profile of the TA cohort. Optimal patient screening, approach selection, and device refinement may improve outcomes

    Cellular mechanisms by which proinsulin C-peptide prevents insulin-induced neointima formation in human saphenous vein

    Get PDF
    AIMS/HYPOTHESIS: Endothelial cells (ECs) and smooth muscle cells (SMCs) play key roles in the development of intimal hyperplasia in saphenous vein (SV) bypass grafts. In diabetic patients, insulin administration controls hyperglycaemia but cardiovascular complications remain. Insulin is synthesised as a pro-peptide, from which C-peptide is cleaved and released into the circulation with insulin; exogenous insulin lacks C-peptide. Here we investigate modulation of human SV neointima formation and SV-EC and SV-SMC function by insulin and C-peptide. METHODS: Effects of insulin and C-peptide on neointima formation (organ cultures), EC and SMC proliferation (cell counting), EC migration (scratch wound), SMC migration (Boyden chamber) and signalling (immunoblotting) were examined. A real-time RT-PCR array identified insulin-responsive genes, and results were confirmed by real-time RT-PCR. Targeted gene silencing (siRNA) was used to assess functional relevance. RESULTS: Insulin (100 nmol/l) augmented SV neointimal thickening (70% increase, 14 days), SMC proliferation (55% increase, 7 days) and migration (150% increase, 6 h); effects were abrogated by 10 nmol/l C-peptide. C-peptide did not affect insulin-induced Akt or extracellular signal-regulated kinase signalling (15 min), but array data and gene silencing implicated sterol regulatory element binding transcription factor 1 (SREBF1). Insulin (1-100 nmol/l) did not modify EC proliferation or migration, whereas 10 nmol/l C-peptide stimulated EC proliferation by 40% (5 days). CONCLUSIONS/INTERPRETATION: Our data support a causative role for insulin in human SV neointima formation with a novel counter-regulatory effect of proinsulin C-peptide. Thus, C-peptide can limit the detrimental effects of insulin on SMC function. Co-supplementing insulin therapy with C-peptide could improve therapy in insulin-treated patients

    Design, Analysis and Testing of a Novel Mitral Valve for Transcatheter Implantation

    Get PDF
    Mitral regurgitation is a common mitral valve dysfunction which may lead to heart failure. Because of the rapid aging of the population, conventional surgical repair and replacement of the pathological valve are often unsuitable for about half of symptomatic patients, who are judged high-risk. Transcatheter valve implantation could represent an effective solution. However, currently available aortic valve devices are inapt for the mitral position. This paper presents the design, development and hydrodynamic assessment of a novel bi-leaflet mitral valve suitable for transcatheter implantation. The device consists of two leaflets and a sealing component made from bovine pericardium, supported by a self-expanding wireframe made from superelastic NiTi alloy. A parametric design procedure based on numerical simulations was implemented to identify design parameters providing acceptable stress levels and maximum coaptation area for the leaflets. The wireframe was designed to host the leaflets and was optimised numerically to minimise the stresses for crimping in an 8 mm sheath for percutaneous delivery. Prototypes were built and their hydrodynamic performances were tested on a cardiac pulse duplicator, in compliance with the ISO5840-3:2013 standard. The numerical results and hydrodynamic tests show the feasibility of the device to be adopted as a transcatheter valve implant for treating mitral regurgitation

    International consensus statement on nomenclature and classification of the congenital bicuspid aortic valve and its aortopathy, for clinical, surgical, interventional and research purposes

    Get PDF
    This International Consensus Classification and Nomenclature for the congenital bicuspid aortic valve condition recognizes 3 types of bicuspid valves: 1. The fused type (right-left cusp fusion, right-non-coronary cusp fusion and left-non-coronary cusp fusion phenotypes); 2. The 2-sinus type (latero-lateral and antero-posterior phenotypes); and 3. The partial-fusion (forme fruste) type. The presence of raphe and the symmetry of the fused type phenotypes are critical aspects to describe. The International Consensus also recognizes 3 types of bicuspid valve-associated aortopathy: 1. The ascending phenotype; 2. The root phenotype; and 3. Extended phenotypes.Cardiolog

    Outcomes following redo sternotomy for aortic surgery

    No full text
    corecore