3,087 research outputs found
Effect of some disease stress on cow milk yield and features
In their review, Bertoni et al. (2003) have pointed out how in dairy cows milk yield and its characteristics are markedly modified during disease stress (general consequences of any disease). This mainly depends on secretion of cytokines, which determines anorexia, endocrine changes and diversion of some nutrients toward the immune system
The First Year of the Large Hadron Collider: A Brief Review
The first year of LHC data taking provided an integrated luminosity of about
35/pb in proton-proton collisions at sqrt(s)=7 TeV. The accelerator and the
experiments have demonstrated an excellent performance. The experiments have
obtained important physics results in many areas, ranging from tests of the
Standard Model to searches for new particles. Among other results the physics
highlights have been the measurements of the W-, Z-boson and t t-bar production
cross-sections, improved limits on supersymmetric and other hypothetical
particles and the observation of jet-quenching, elliptical flow and J/Psi
suppression in lead-lead collisions at sqrt(sNN) = 2.76 TeV.Comment: 11 pages, 9 figures, invited brief review for Mod. Phys. Lett.
Adherence and Constancy in LIME-RS Explanations for Recommendation
Explainable Recommendation has attracted a lot of attention due to a renewed interest in explainable artificial intelligence. In
particular, post-hoc approaches have proved to be the most easily applicable ones to increasingly complex recommendation
models, which are then treated as black boxes. The most recent literature has shown that for post-hoc explanations based
on local surrogate models, there are problems related to the robustness of the approach itself. This consideration becomes
even more relevant in human-related tasks like recommendation. The explanation also has the arduous task of enhancing
increasingly relevant aspects of user experience such as transparency or trustworthiness. This paper aims to show how
the characteristics of a classical post-hoc model based on surrogates is strongly model-dependent and does not prove to be
accountable for the explanations generatedThe authors acknowledge partial support of PID2019-108965GB-I00, PONARS01_00876BIO-D,CasadelleTecnologie
mergenti della CittĂ di Matera, PONARS01_00821FLET4.0, PIAServiziLocali2.0,H2020Passapartout-Grantn. 101016956, PIAERP4.0,andIPZS-PRJ4_IA_NORMATIV
Genomic segmental duplications on the basis of the t(9;22) rearrangement in chronic myeloid leukemia
n/
Effect of oral consumption of capsules containing Lactobacillus paracasei LPC-S01 on the vaginal microbiota of healthy adult women: a randomized, placebo-controlled, double-blind crossover study
Oral consumption of probiotics is practical and can be an effective solution to preserve vaginal eubiosis. Here, we studied the ability of orally administered Lactobacillus paracasei LPC-S01 (DSM 26760) to affect the composition of the vaginal microbiota and colonize the vaginal mucosa in nondiseased adult women. A total of 40 volunteers took oral probiotic (24 billion CFU) or placebo capsules daily for 4 weeks, and after a 4-week washout, they switched to placebo or probiotic capsules according to the crossover design. A total of 23 volunteers completed the study according to the protocol. Before and after capsule ingestion, vaginal swabs were collected for qPCR quantification to detect L. paracasei LPC-S01 and for 16S rRNA gene sequencing. Vaginal swabs were grouped according to their bacterial taxonomic structure into nine community state types (CSTs), four of which were dominated by lactobacilli. Lactobacillus paracasei LPC-S01 was detected in the vagina of two participants. Statistical modeling (including linear mixed-effects model analysis) demonstrated that daily intake of probiotic capsules reduced the relative abundance of Gardnerella spp. Quantitative PCR with Gardnerella vaginalis primers confirmed this result. Considering the pathogenic nature of G. vaginalis, these results suggest a potential positive effect of this probiotic capsule on the vaginal microbial ecosystem
Performance of ALICE pixel prototypes in high energy beams
The two innermost layers of the ALICE inner tracking system are instrumented
with silicon pixel detectors. Single chip assembly prototypes of the ALICE
pixels have been tested in high energy particle beams at the CERN SPS.
Detection efficiency and spatial precision have been studied as a function of
the threshold and the track incidence angle. The experimental method, data
analysis and main results are presented.Comment: 10 pages, 9 figures, contribution to PIX2005 Workshop, Bonn
(Germany), 5-8 September 200
Beam Test Performance and Simulation of Prototypes for the ALICE Silicon Pixel Detector
The silicon pixel detector (SPD) of the ALICE experiment in preparation at
the Large Hadron Collider (LHC) at CERN is designed to provide the precise
vertex reconstruction needed for measuring heavy flavor production in heavy ion
collisions at very high energies and high multiplicity. The SPD forms the
innermost part of the Inner Tracking System (ITS) which also includes silicon
drift and silicon strip detectors. Single assembly prototypes of the ALICE SPD
have been tested at the CERN SPS using high energy proton/pion beams in 2002
and 2003. We report on the experimental determination of the spatial precision.
We also report on the first combined beam test with prototypes of the other ITS
silicon detector technologies at the CERN SPS in November 2004. The issue of
SPD simulation is briefly discussed.Comment: 4 pages, 5 figures, prepared for proceedings of 7th International
Position Sensitive Detectors Conference, Liverpool, Sept. 200
Proton-proton elastic scattering at the LHC energy of {\surd} = 7 TeV
Proton-proton elastic scattering has been measured by the TOTEM experiment at
the CERN Large Hadron Collider at {\surd}s = 7 TeV in dedicated runs with the
Roman Pot detectors placed as close as seven times the transverse beam size
(sbeam) from the outgoing beams. After careful study of the accelerator optics
and the detector alignment, |t|, the square of four-momentum transferred in the
elastic scattering process, has been determined with an uncertainty of d t =
0.1GeV p|t|. In this letter, first results of the differential cross section
are presented covering a |t|-range from 0.36 to 2.5GeV2. The differential
cross-section in the range 0.36 < |t| < 0.47 GeV2 is described by an
exponential with a slope parameter B = (23.6{\pm}0.5stat {\pm}0.4syst)GeV-2,
followed by a significant diffractive minimum at |t| =
(0.53{\pm}0.01stat{\pm}0.01syst)GeV2. For |t|-values larger than ~ 1.5GeV2, the
cross-section exhibits a power law behaviour with an exponent of -7.8_\pm}
0.3stat{\pm}0.1syst. When compared to predictions based on the different
available models, the data show a strong discriminative power despite the small
t-range covered.Comment: 12pages, 5 figures, CERN preprin
Multi-GeV Electron Spectrometer
The advance in laser plasma acceleration techniques pushes the regime of the
resulting accelerated particles to higher energies and intensities. In
particular the upcoming experiments with the FLAME laser at LNF will enter the
GeV regime with almost 1pC of electrons. From the current status of
understanding of the acceleration mechanism, relatively large angular and
energy spreads are expected. There is therefore the need to develop a device
capable to measure the energy of electrons over three orders of magnitude (few
MeV to few GeV) under still unknown angular divergences. Within the PlasmonX
experiment at LNF a spectrometer is being constructed to perform these
measurements. It is made of an electro-magnet and a screen made of
scintillating fibers for the measurement of the trajectories of the particles.
The large range of operation, the huge number of particles and the need to
focus the divergence present unprecedented challenges in the design and
construction of such a device. We will present the design considerations for
this spectrometer and the first results from a prototype.Comment: 7 pages, 6 figures, submitted to NIM
- …