33 research outputs found

    Trinta anos de sintaxe gerativa no Brasil

    Full text link

    Prevalence, associated factors and outcomes of pressure injuries in adult intensive care unit patients: the DecubICUs study

    Get PDF
    Funder: European Society of Intensive Care Medicine; doi: http://dx.doi.org/10.13039/501100013347Funder: Flemish Society for Critical Care NursesAbstract: Purpose: Intensive care unit (ICU) patients are particularly susceptible to developing pressure injuries. Epidemiologic data is however unavailable. We aimed to provide an international picture of the extent of pressure injuries and factors associated with ICU-acquired pressure injuries in adult ICU patients. Methods: International 1-day point-prevalence study; follow-up for outcome assessment until hospital discharge (maximum 12 weeks). Factors associated with ICU-acquired pressure injury and hospital mortality were assessed by generalised linear mixed-effects regression analysis. Results: Data from 13,254 patients in 1117 ICUs (90 countries) revealed 6747 pressure injuries; 3997 (59.2%) were ICU-acquired. Overall prevalence was 26.6% (95% confidence interval [CI] 25.9–27.3). ICU-acquired prevalence was 16.2% (95% CI 15.6–16.8). Sacrum (37%) and heels (19.5%) were most affected. Factors independently associated with ICU-acquired pressure injuries were older age, male sex, being underweight, emergency surgery, higher Simplified Acute Physiology Score II, Braden score 3 days, comorbidities (chronic obstructive pulmonary disease, immunodeficiency), organ support (renal replacement, mechanical ventilation on ICU admission), and being in a low or lower-middle income-economy. Gradually increasing associations with mortality were identified for increasing severity of pressure injury: stage I (odds ratio [OR] 1.5; 95% CI 1.2–1.8), stage II (OR 1.6; 95% CI 1.4–1.9), and stage III or worse (OR 2.8; 95% CI 2.3–3.3). Conclusion: Pressure injuries are common in adult ICU patients. ICU-acquired pressure injuries are associated with mainly intrinsic factors and mortality. Optimal care standards, increased awareness, appropriate resource allocation, and further research into optimal prevention are pivotal to tackle this important patient safety threat

    Another reason for intra-operative imaging during cochlear implantation

    No full text
    Objective: We report a case of a rare cochlear implant complication: the introduction of the electrode array into the superior semicircular canal, with intra-operative measurements of neural response reactions suggesting reasonable functioning of the implant. Case report: A two-year old patient affected by congenital, profound, sensorineural deafness underwent bilateral cochlear implantation at the ENT clinic of the 'La Sapienza' University of Rome. Two Clarion 90k devices were implanted, and electrophysiological and radiological checks were performed. After the introduction of the array in the right side, neural response imaging was performed, and a neural potential was found only on two apical electrodes, at a stimulation intensity of 431 clinical units. The situation differed on the left side, where neural response imaging was present at a stimulation intensity of 300 clinical units on the two electrodes tested (one apical electrode (number three), and one middle electrode (number nine)). Intra-operative radiological assessment with a transorbital plain films was performed as usual in order to assess the position of the electrodes inside the cochlea. This radiography showed the electrode array to be in the superior semicircular canal in the right ear. Conclusion: Intra-operative monitoring tests during cochlear implant surgery play different roles; measurement of impedances and neural response imaging can evaluate the integrity of implant electrodes and the status of the electrode-cochlea interface, but it must not be the sole way in which correct positioning of the array is confirmed. In our opinion, intra-operative radiological assessment is mandatory during cochlear implant surgery. © 2008 JLO (1984) Limited

    Nasal endoscopy associated with coronal CT in the diagnosis of non- allergic chronic nasal obstruction.

    No full text

    Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants

    No full text
    Conclusion. The image quality of 64-MDCT provided excellent definition of the fine osseous structures and individual electrode contacts. Evaluation of electrode distances revealed a more focused stimulation for the Helix contacts, with better optimization of pulse width and frequency of stimulation. Objectives. A multi-slice CT scan was performed postoperatively to evaluate electrode distance from the modiolus and variability of fitting parameters ( M level) for two different types of cochlear implant electrode carriers, CII and 90K implants with 1J and Helix electrode carriers. Materials and methods. The electrode's position in different cochlear implant (CI) electrodes, Advanced Bionics 90K 1J and Helix, was assessed postoperatively in 20 adult patients by means of a 64-MDCT scanner. Axial, coronal, and oblique 0.3 mm multiplanar reconstructions ( MPRs) were obtained and datasets were analyzed to assess the intracochlear position and distance from the surface of the electrodes to the bony edge of the modiolus. Patients' fitting characteristics were gathered at the time the CT was performed and correlated to intracochlear measurements. Results. Determination of contact distances confirmed smaller average values for the Helix at the apex and medial segments. Helix electrodes were closer to the modiolus in all segments. Likewise, M level determination showed lower values for the Helix carrier, confirming a more focused stimulation and better optimization of pulse width and frequency of stimulation
    corecore