248 research outputs found

    Role of the direct processes in low-energy deuteron interactions

    Full text link
    An extended analysis of the key role of direct interactions, i.e., breakup, stripping and pick-up processes, has been carried out for deuteron-induced reactions. Particular comments concern the deuteron breakup which is the dominant mechanism involved in surrogate reactions on heavy nuclei, around the Coulomb barrier.Comment: 5 pages, 3 figures. Contribution at Int. Conf. on Nucl. Data for Science and Technology (ND2016), 11-16.09.2016, Bruges, Belgiu

    Enhanced spin accumulation at room temperature in graphene spin valves with amorphous carbon interfacial layers

    Get PDF
    We demonstrate a large enhancement of the spin accumulation in monolayer graphene following electron-beam induced deposition of an amorphous carbon layer at the ferromagnet-graphene interface. The enhancement is 10^4-fold when graphene is deposited onto poly(methyl metacrylate) (PMMA) and exposed with sufficient electron-beam dose to cross-link the PMMA, and 10^3-fold when graphene is deposited directly onto SiO2 and exposed with identical dose. We attribute the difference to a more efficient carbon deposition in the former case due to an increase in the presence of compounds containing carbon, which are released by the PMMA. The amorphous carbon interface can sustain very large current densities without degrading, which leads to very large spin accumulations exceeding 500 microeVs at room temperature

    All Magnesium diboride Josephson Junctions with MgO and native oxide barriers

    Full text link
    We present results on all-MgB2 tunnel junctions, where the tunnel barrier is deposited MgO or native-oxide of base electrode. For the junctions with MgO, the hysteretic I-V curve resembles a conventional underdamped Josephson junction characteristic with critical current-resistance product nearly independent of the junction area. The dependence of the critical current with temperature up to 20 K agrees with the [Ambegaokar and Baratoff, Phys. Rev. Lett. 10, 486 (1963)] expression. For the junctions with native-oxide, conductance at low bias exhibits subgap features while at high bias reveals thick barriers. As a result no supercurrent was observed in the latter, despite the presence of superconducting-gaps to over 30 K.Comment: 8 pages with 3 figure

    Fingerprints of Inelastic Transport at the Surface of the Topological Insulator Bi2Se3: Role of Electron-Phonon Coupling

    Get PDF
    We report on electric-field and temperature dependent transport measurements in exfoliated thin crystals of Bi2_{2}Se3_{3} topological insulator. At low temperatures (<50< 50 K) and when the chemical potential lies inside the bulk gap, the crystal resistivity is strongly temperature dependent, reflecting inelastic scattering due to the thermal activation of optical phonons. A linear increase of the current with voltage is obtained up to a threshold value at which current saturation takes place. We show that the activated behavior, the voltage threshold and the saturation current can all be quantitatively explained by considering a single optical phonon mode with energy Ω8\hbar \Omega \approx 8 meV. This phonon mode strongly interacts with the surface states of the material and represents the dominant source of scattering at the surface at high electric fields.Comment: Supplementary Material at: http://journals.aps.org/prl/supplemental/10.1103/PhysRevLett.112.086601/TIPhonon_SM.pd

    Spin accumulation probed in multiterminal lateral all-metallic devices

    Get PDF
    We study spin accumulation in an aluminium island, in which the injection of a spin current and the detection of the spin accumulation are done by means of four cobalt electrodes that connect to the island through transparent tunnel barriers. Although the four electrodes are designed as two electrode pairs of the same shape, they nonetheless all exhibit distinct switching fields. As a result the device can have several different magnetic configurations. From the measurements of the amplitude of the spin accumulation, we can identify these configurations, and using the diffusion equation for the spin imbalance, we extract the spin relaxation length λsf=400±50\lambda_\mathrm{sf} = 400 \pm 50~nm and an interface spin current polarization P=(10±1)P = (10 \pm 1)% at low temperature and λsf=350±50\lambda_\mathrm{sf} = 350 \pm 50~nm, P=(8±1)P = (8 \pm 1)% at room temperature

    Spin precession and spin Hall effect in monolayer graphene/Pt nanostructures

    Get PDF
    Spin Hall effects have surged as promising phenomena for spin logics operations without ferromagnets. However, the magnitude of the detected electric signals at room temperature in metallic systems has been so far underwhelming. Here, we demonstrate a two-order of magnitude enhancement of the signal in monolayer graphene/Pt devices when compared to their fully metallic counterparts. The enhancement stems in part from efficient spin injection and the large resistivity of graphene but we also observe 100% spin absorption in Pt and find an unusually large effective spin Hall angle of up to 0.15. The large spin-to-charge conversion allows us to characterise spin precession in graphene under the presence of a magnetic field. Furthermore, by developing an analytical model based on the 1D diffusive spin-transport, we demonstrate that the effective spin-relaxation time in graphene can be accurately determined using the (inverse) spin Hall effect as a means of detection. This is a necessary step to gather full understanding of the consequences of spin absorption in spin Hall devices, which is known to suppress effective spin lifetimes in both metallic and graphene systems.Comment: 14 pages, 6 figures. Accepted in 2D Materials. https://doi.org/10.1088/2053-1583/aa882

    Voltage generation by ferromagnetic resonance

    Get PDF
    A ferromagnet can resonantly absorbs rf radiation to sustain a steady precession of the magnetization around an internal or applied magnetic field. We show that under these ferromagnetic resonance (FMR) conditions, a dc voltage is generated at a normal-metal electric contact to a ferromagnet with spin-flip scattering. This mechanism allows an easy electric detection of magnetization dyamics

    Large cone angle magnetization precession of an individual nanomagnet with dc electrical detection

    Get PDF
    We demonstrate on-chip resonant driving of large cone-angle magnetization precession of an individual nanoscale permalloy element. Strong driving is realized by locating the element in close proximity to the shorted end of a coplanar strip waveguide, which generates a microwave magnetic field. We used a microwave frequency modulation method to accurately measure resonant changes of the dc anisotropic magnetoresistance. Precession cone angles up to 909^{0} are determined with better than one degree of resolution. The resonance peak shape is well-described by the Landau-Lifshitz-Gilbert equation

    Linear and nonlinear parameters of heart rate variability in ischemic stroke patients

    Get PDF
    Introduction Cardiovascular system presents cortical modulation. Post-stroke outcome can be highly influenced by autonomic nervous system disruption. Heart rate variability (HRV) analysis is a simple non-invasive method to assess sympatho-vagal balance. Objectives The purpose of this study was to investigate cardiac autonomic activity in ischemic stroke patients and to asses HRV nonlinear parameters beside linear ones. Methods We analyzed HRV parameters in 15 right and 15 left middle cerebral artery ischemic stroke patients, in rest condition and during challenge (standing and deep breathing). Data were compared with 15 age- and sex-matched healthy controls. Results There was an asymmetric response after autonomic stimulation tests depending on the cortical lateralization in ischemic stroke patients. In resting state, left hemisphere stroke patients presented enhanced parasympathetic control of the heart rate (higher values for RMSSD, pNN50 and HF in normalized units). Right hemisphere ischemic stroke patients displayed a reduced cardiac parasympathetic modulation during deep breathing test. Beside time and frequency domain, using short-term ECG monitoring, cardiac parasympathetic modulation can also be assessed by nonlinear parameter SD1, that presented strong positive correlation with time and frequency domain parameters RMSSD, pNN50, HFnu, while DFA α1 index presented negative correlation with the same indices and positive correlation with the LFnu and LF/HF ratio, indicating a positive association with the sympatho-vagal balance. Conclusions Cardiac monitoring in clinical routine using HRV analysis in order to identify autonomic imbalance may highlight cardiac dysfunctions, thus helping preventing potential cardiovascular complications, especially in right hemisphere ischemic stroke patients with sympathetic hyperactivation
    corecore