17 research outputs found

    Surveillance of antimicrobial resistance at a tertiary hospital in Tanzania

    Get PDF
    BACKGROUND: Antimicrobial resistance is particularly harmful to infectious disease management in low-income countries since expensive second-line drugs are not readily available. The objective of this study was to implement and evaluate a computerized system for surveillance of antimicrobial resistance at a tertiary hospital in Tanzania. METHODS: A computerized surveillance system for antimicrobial susceptibility (WHONET) was implemented at the national referral hospital in Tanzania in 1998. The antimicrobial susceptibilities of all clinical bacterial isolates received during an 18 months' period were recorded and analyzed. RESULTS: The surveillance system was successfully implemented at the hospital. This activity increased the focus on antimicrobial resistance issues and on laboratory quality assurance issues. The study identified specific nosocomial problems in the hospital and led to the initiation of other prospective studies on prevalence and antimicrobial susceptibility of bacterial infections. Furthermore, the study provided useful data on antimicrobial patterns in bacterial isolates from the hospital. Gram-negative bacteria displayed high rates of resistance to common inexpensive antibiotics such as ampicillin, tetracycline and trimethoprim-sulfamethoxazole, leaving fluoroquinolones as the only reliable oral drugs against common Gram-negative bacilli. Gentamicin and third generation cephalosporins remain useful for parenteral therapy. CONCLUSION: The surveillance system is a low-cost tool to generate valuable information on antimicrobial resistance, which can be used to prepare locally applicable recommendations on antimicrobial use. The system pinpoints relevant nosocomial problems and can be used to efficiently plan further research. The surveillance system also functions as a quality assurance tool, bringing attention to methodological issues in identification and susceptibility testing

    Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania

    Get PDF
    BACKGROUND: Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. METHODS: Five rapid HIV assays: Determine HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). RESULTS: Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9), respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold, Determine and SD Bioline assays. CONCLUSION: An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive samples on the Determine or SD Bioline gave 100% sensitivity (95% CI; 99.1-100) and 100% specificity (95% CI; 96-99.1) with Uni-Gold as tiebreaker for discordant results

    Antimicrobial resistance predicts death in Tanzanian children with bloodstream infections: a prospective cohort study

    Get PDF
    Bloodstream infection is a common cause of hospitalization, morbidity and death in children. The impact of antimicrobial resistance and HIV infection on outcome is not firmly established. We assessed the incidence of bloodstream infection and risk factors for fatal outcome in a prospective cohort study of 1828 consecutive admissions of children aged zero to seven years with signs of systemic infection. Blood was obtained for culture, malaria microscopy, HIV antibody test and, when necessary, HIV PCR. We recorded data on clinical features, underlying diseases, antimicrobial drug use and patients' outcome. The incidence of laboratory-confirmed bloodstream infection was 13.9% (255/1828) of admissions, despite two thirds of the study population having received antimicrobial therapy prior to blood culture. The most frequent isolates were klebsiella, salmonellae, Escherichia coli, enterococci and Staphylococcus aureus. Furthermore, 21.6% had malaria and 16.8% HIV infection. One third (34.9%) of the children with laboratory-confirmed bloodstream infection died. The mortality rate from Gram-negative bloodstream infection (43.5%) was more than double that of malaria (20.2%) and Gram-positive bloodstream infection (16.7%). Significant risk factors for death by logistic regression modeling were inappropriate treatment due to antimicrobial resistance, HIV infection, other underlying infectious diseases, malnutrition and bloodstream infection caused by Enterobacteriaceae, other Gram-negatives and candida. Bloodstream infection was less common than malaria, but caused more deaths. The frequent use of antimicrobials prior to blood culture may have hampered the detection of organisms susceptible to commonly used antimicrobials, including pneumococci, and thus the study probably underestimates the incidence of bloodstream infection. The finding that antimicrobial resistance, HIV-infection and malnutrition predict fatal outcome calls for renewed efforts to curb the further emergence of resistance, improve HIV care and nutrition for children

    Selected hematologic and biochemical measurements in African HIV-infected and uninfected pregnant women and their infants: the HIV Prevention Trials Network 024 protocol

    Get PDF
    Reference values for hematological and biochemical assays in pregnant women and in newborn infants are based primarily on Caucasian populations. Normative data are limited for populations in sub-Saharan Africa, especially comparing women with and without HIV infection, and comparing infants with and without HIV infection or HIV exposure. We determined HIV status and selected hematological and biochemical measurements in women at 20-24 weeks and at 36 weeks gestation, and in infants at birth and 4-6 weeks of age. All were recruited within a randomized clinical trial of antibiotics to prevent chorioamnionitis-associated mother-to-child transmission of HIV (HPTN024). We report nearly complete laboratory data on 2,292 HIV-infected and 367 HIV-uninfected pregnant African women who were representative of the public clinics from which the women were recruited. Nearly all the HIV-infected mothers received nevirapine prophylaxis at the time of labor, as did their infants after birth (always within 72 hours of birth, but typically within just a few hours at the four study sites in Malawi (2 sites), Tanzania, and Zambia. HIV-infected pregnant women had lower red blood cell counts, hemoglobin, hematocrit, and white blood cell counts than HIV-uninfected women. Platelet and monocyte counts were higher among HIV-infected women at both time points. At the 4-6-week visit, HIV-infected infants had lower hemoglobin, hematocrit and white blood cell counts than uninfected infants. Platelet counts were lower in HIV-infected infants than HIV-uninfected infants, both at birth and at 4-6 weeks of age. At 4-6 weeks, HIV-infected infants had higher alanine aminotransferase measures than uninfected infants. Normative data in pregnant African women and their newborn infants are needed to guide the large-scale HIV care and treatment programs being scaled up throughout the continent. These laboratory measures will help interpret clinical data and assist in patient monitoring in a sub-Saharan Africa context

    Factors associated with mortality in HIV-infected and uninfected patients with pulmonary tuberculosis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>HIV has fuelled the TB epidemic in sub-Saharan Africa. Mortality in patients co-infected with TB and HIV is high. Managing factors influencing mortality in TB patients might help reducing it. This study investigates factors associated with mortality including patients' HIV sero-status, CD4 cell count, laboratory, nutritional and demographic characteristics in AFB smear positive pulmonary TB patients.</p> <p>Methods</p> <p>We studied 887 sputum smear positive PTB patients, between 18 and 65 years of age receiving standard 8 months anti-TB treatment. Demographic, anthropometric and laboratory data including HIV, CD4 and other tests were collected at baseline and at regular intervals. Patients were followed for a median period of 2.5 years.</p> <p>Results</p> <p>Of the 887 participants, 155 (17.5%) died, of whom 90.3% (140/155) were HIV-infected, a fatality of 29.7% (140/471) compared to 3.6% (15/416) among HIV-uninfected. HIV infection, age, low Karnofsky score, CD4 cell counts and hemoglobin, high viral load, and oral thrush were significantly associated with high mortality in all patients.</p> <p>Conclusion</p> <p>Mortality among HIV-infected TB patients is high despite the use of effective anti-TB therapy. Most deaths occur after successful completion of therapy, an indication that patients die from causes other than TB. HIV infection is the strongest independent predictor of mortality in this cohort.</p

    WHO multicenter evaluation of FACSCount CD4 and Pima CD4 T-cell count systems : instrument performance and misclassification of HIV-infected patients

    Get PDF
    CD4⁺ T-cell counts are used to screen and follow-up HIV-infected patients during treatment. As part of the World Health Organization prequalification program of diagnostics, we conducted an independent multicenter evaluation of the FACSCount CD4 and the Pima CD4, using the FACSCalibur as reference method. A total of 440 paired capillary and venous blood samples were collected from HIV-infected patients attending the HIV outpatient clinic in Antwerp, Belgium, and the HIV care and treatment center in Dar es Salam, Tanzania. Capillary blood was run on Pima analyzer, whereas venous blood was analyzed on FACSCount, Pima, and FACSCalibur instruments. Precision and agreement between methods were assessed. The FACSCount CD4 results were in agreement with the FACSCalibur results with relative bias of 0.4% and 3.1% on absolute CD4 counts and an absolute bias of -0.6% and -1.1% on CD4% in Antwerp and Dar es Salam, respectively. The Pima CD4 results were in agreement with the FACSCalibur results with relative bias of -4.1% and -9.4% using venous blood and of -9.5% and -0.9% using capillary blood in Antwerp and Dar es Salam, respectively. At the threshold of 350 cells per microliter, the FACSCount CD4 and Pima CD4 using venous and capillary blood misclassified 7%, 9%, and 13% of patients, respectively. The FACSCount CD4 provides reliable CD4 counts and CD4% and is suitable for monitoring adult and pediatric HIV patients in moderate-volume settings. The Pima CD4 is more suitable for screening eligible adult HIV patients for antiretroviral treatment initiation in low-volume laboratories

    Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania

    No full text
    Abstract Background Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Methods Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1–2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold™ HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Results Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1–100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2–99.9) and 97.7% (95% CI; 95.7–98.9), respectively, which increased to 100% (95% CI; 99.1–100) on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6–100) while specificities were 99.6% (95% CI; 99–99.9), 99.4% (95% CI; 98.8–99.7), 99.6% (95% CI; 99–99.9) and 99.8% (95% CI; 99.3–99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold™, Determine and SD Bioline assays. Conclusion An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive samples on the Determine or SD Bioline gave 100% sensitivity (95% CI; 99.1–100) and 100% specificity (95% CI; 96–99.1) with Uni-Gold™ as tiebreaker for discordant results.</p
    corecore