132 research outputs found

    Challenges and Barriers of Wireless Charging Technologies for Electric Vehicles

    Get PDF
    Electric vehicles could be a significant aid in lowering greenhouse gas emissions. Even though extensive study has been done on the features and traits of electric vehicles and the nature of their charging infrastructure, network modeling for electric vehicle manufacturing has been limited and unchanging. The necessity of wireless electric vehicle charging, based on magnetic resonance coupling, drove the primary aims for this review work. Herein, we examined the basic theoretical framework for wireless power transmission systems for EV charging and performed a software-in-the-loop analysis, in addition to carrying out a performance analysis of an EV charging system based on magnetic resonance. This study also covered power pad designs and created workable remedies for the following issues: (i) how power pad positioning affected the function of wireless charging systems and (ii) how to develop strategies to keep power efficiency at its highest level. Moreover, safety features of wireless charging systems, owing to interruption from foreign objects and/or living objects, were analyzed, and solutions were proposed to ensure such systems would operate as safely and optimally as possible

    Design of an epithermal column for BNCT based on D–D fusion neutron facility

    Get PDF
    Abstract Boron Neutron Capture Therapy (BNCT) is currently performed on patients at nuclear reactors. At the same time the international BNCT community is engaged in the development of alternative facilities for in-hospital treatments. This paper investigates the potential of a novel high-output D–D neutron generator, developed at Lawrence Berkeley National Laboratory (CA, USA), for BNCT. The simulation code MCNP-4C is used to realize an accurate study of the epithermal column in view of the treatment of deep tumours. Different materials and Beam Shaping Assemblies (BSA) are investigated and an optimized configuration is proposed. The neutron beam quality is defined by the standard free beam parameters, calculated averaging over the collimator aperture. The results are discussed and compared with the performances of other facilities

    Excitation and relaxation in atom-cluster collisions

    Get PDF
    Electronic and vibrational degrees of freedom in atom-cluster collisions are treated simultaneously and self-consistently by combining time-dependent density functional theory with classical molecular dynamics. The gradual change of the excitation mechanisms (electronic and vibrational) as well as the related relaxation phenomena (phase transitions and fragmentation) are studied in a common framework as a function of the impact energy (eV...MeV). Cluster "transparency" characterized by practically undisturbed atom-cluster penetration is predicted to be an important reaction mechanism within a particular window of impact energies.Comment: RevTeX (4 pages, 4 figures included with epsf

    Dosimetric characterization of a large area pixel-segmented ionization chamber.

    Get PDF
    A pixel-segmented ionization chamber has been designed and built by Torino University and INFN. The detector features a 24 x 24 cm2 active area divided in 1024 independent cylindrical ionization chambers and can be read out in 500 micros without introducing dead time; the digital charge quantum can be adjusted between 100 fC and 800 fC. The sensitive volume of each single ionization chamber is 0.07 cm3. The purpose of the detector is to ease the two-dimensional (2D) verifications of fields with complex shapes and large gradients. The detector was characterized in a PMMA phantom using 60Co and 6 MV x-ray photon beams. It has shown good signal linearity with respect to dose and dose rate to water. The average sensitivity of a single ionization chamber was 2.1 nC/Gy, constant within 0.5% over one month of daily measurements. Charge collection efficiency was 0.985 at the operating polarization voltage of 400 V and 3.5 Gy/min dose rate. Tissue maximum ratio and output factor have been compared with a Farmer ionization chamber and were found in good agreement. The dose profiles have been compared with the ones obtained with an ionization chamber in water phantom for the field sizes supplied by a 3D-Line dynamic multileaf collimator. These results show that this detector can be used for 2D dosimetry of x-ray photon beams, supplying a good spatial resolution and sensibly reducing the time spent in dosimetric verification of complex radiation fields

    a Solution for Dosimetry and Quality Assurance in Imrt and Hadrontherapy:. the Pixel Ionization Chamber

    Get PDF
    The new radiotherapy techniques require new detectors to monitor and measure the clinical field. The Intensity Modulated Radiation Therapy (IMRT) techniques like step and shoot, sliding window, dynamic wedge or scanning beam add the time variable to the treatment field. In this case the water phantom with a single ionization chamber moving inside the field needs very long measurement time. Linear arrays of ionization chambers or diodes measure the field only along a line. 2D detectors like radiographic or gafchromic film are not suitable to be used as on line detectors. We have developed, built and tested an ionization chamber segmented in pixels that measure the dose in a plane at several points. Every channel has a dedicated electronic chain that digitizes the collected charge and data from all the channels are sent to the computer that performs the data acquisition. One read out cycle is very fast allowing to measure in real time the fluency and the shape of the field. The chamber can be used in two different ways, as monitor chamber and as relative dosemeter. A description of the detector, the electronics, and test results with both photon and hadron beams will be reported

    JUNO Conceptual Design Report

    Get PDF
    The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the detection of reactor antineutrinos can resolve the neutrino mass hierarchy at a confidence level of 3-4σ\sigma, and determine neutrino oscillation parameters sin2θ12\sin^2\theta_{12}, Δm212\Delta m^2_{21}, and Δmee2|\Delta m^2_{ee}| to an accuracy of better than 1%. The JUNO detector can be also used to study terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model. The central detector contains 20,000 tons liquid scintillator with an acrylic sphere of 35 m in diameter. \sim17,000 508-mm diameter PMTs with high quantum efficiency provide \sim75% optical coverage. The current choice of the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of detected photoelectrons per MeV is larger than 1,100 and the energy resolution is expected to be 3% at 1 MeV. The calibration system is designed to deploy multiple sources to cover the entire energy range of reactor antineutrinos, and to achieve a full-volume position coverage inside the detector. The veto system is used for muon detection, muon induced background study and reduction. It consists of a Water Cherenkov detector and a Top Tracker system. The readout system, the detector control system and the offline system insure efficient and stable data acquisition and processing.Comment: 328 pages, 211 figure

    A realist evaluation of a physical activity participation intervention for children and youth with disabilities: What works, for whom, in what circumstances, and how?

    Get PDF
    Background: The need to identify strategies that facilitate involvement in physical activity for children and youth with disabilities is recognised as an urgent priority. This study aimed to describe the association between context, mechanisms and outcome(s) of a participation-focused physical activity intervention to understand what works, in what conditions, and how. Methods: This study was designed as a realist evaluation. Participant recruitment occurred through purposive and theoretical sampling of children and parents participating in the Local Environment Model intervention at Beitostolen Healthsports Centre in Norway. Ethnographic methods comprising participant observation, interviews, and focus groups were employed over 15 weeks in the field. Data analysis was completed using the context-mechanism-outcome framework of realist evaluation. Context-mechanism-outcome connections were generated empirically from the data to create a model to indicate how the program activated mechanisms within the program context, to enable participation in physical activity. Results: Thirty one children with a range of disabilities (mean age 12y 6 m (SD 2y 2 m); 18 males) and their parents (n=44; 26 mothers and 18 fathers) participated in the study. Following data synthesis, a refined program theory comprising four context themes, five mechanisms, and six outcomes, were identified. The mechanisms (choice, fun, friends, specialised health professionals, and time) were activated in a context that was safe, social, learning-based and family-centred, to elicit outcomes across all levels of the International Classification of Functioning, Disability and Health. Conclusions: The interaction of mechanisms and context as a whole facilitated meaningful outcomes for children and youth with disabilities, and their parents. Whilst optimising participation in physical activity is a primary outcome of the Local Environment Model, the refined program theory suggests the participation-focused approach may act as a catalyst to promote a range of outcomes. Findings from this study may inform future interventions attempting to enable participation in physical activity for children and youth with disabilities

    Sicily statement on classification and development of evidence-based practice learning assessment tools

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Teaching the steps of evidence-based practice (EBP) has become standard curriculum for health professions at both student and professional levels. Determining the best methods for evaluating EBP learning is hampered by a dearth of valid and practical assessment tools and by the absence of guidelines for classifying the purpose of those that exist. Conceived and developed by delegates of the Fifth International Conference of Evidence-Based Health Care Teachers and Developers, the aim of this statement is to provide guidance for purposeful classification and development of tools to assess EBP learning.</p> <p>Discussion</p> <p>This paper identifies key principles for designing EBP learning assessment tools, recommends a common taxonomy for new and existing tools, and presents the Classification Rubric for EBP Assessment Tools in Education (CREATE) framework for classifying such tools. Recommendations are provided for developers of EBP learning assessments and priorities are suggested for the types of assessments that are needed. Examples place existing EBP assessments into the CREATE framework to demonstrate how a common taxonomy might facilitate purposeful development and use of EBP learning assessment tools.</p> <p>Summary</p> <p><it>The widespread adoption of EBP into professional education requires valid and reliable measures of learning. Limited tools exist with established psychometrics. This international consensus statement strives to provide direction for developers of new EBP learning assessment tools and a framework for classifying the purposes of such tools</it>.</p

    Spinal deformities rehabilitation - state of the art review

    Get PDF
    corecore