622 research outputs found

    Force-induced unfolding of a homopolymer on fractal lattice: exact results vs. mean field predictions

    Full text link
    We study the force-induced unfolding of a homopolymer on the three dimensional Sierpinski gasket. The polymer is subject to a contact energy between nearest neighbour sites not consecutive along the chain and to a stretching force. The hierarchical nature of the lattice we consider allows for an exact treatment which yields the phase diagram and the critical behaviour. We show that for this model mean field predictions are not correct, in particular in the exact phase diagram there is {\em not} a low temperature reentrance and we find that the force induced unfolding transition below the theta temperature is second order.Comment: 15 pages, 5 eps figure

    Design considerations for table-top, laser-based VUV and X-ray free electron lasers

    Get PDF
    A recent breakthrough in laser-plasma accelerators, based upon ultrashort high-intensity lasers, demonstrated the generation of quasi-monoenergetic GeV-electrons. With future Petawatt lasers ultra-high beam currents of ~100 kA in ~10 fs can be expected, allowing for drastic reduction in the undulator length of free-electron-lasers (FELs). We present a discussion of the key aspects of a table-top FEL design, including energy loss and chirps induced by space-charge and wakefields. These effects become important for an optimized table-top FEL operation. A first proof-of-principle VUV case is considered as well as a table-top X-ray-FEL which may open a brilliant light source also for new ways in clinical diagnostics.Comment: 6 pages, 4 figures; accepted for publication in Appl. Phys.

    Cardiac magnetic resonance findings predict increased resource utilization in elective coronary artery bypass grafting

    Get PDF
    Morbidity following CABG (coronary artery bypass grafting) is difficult to predict and leads to increased healthcare costs. We hypothesized that pre-operative CMR (cardiac magnetic resonance) findings would predict resource utilization in elective CABG. Over a 12-month period, patients requiring elective CABG were invited to undergo CMR 1 day prior to CABG. Gadolinium-enhanced CMR was performed using a trueFISP inversion recovery sequence on a 1.5 tesla scanner (Sonata; Siemens). Clinical data were collected prospectively. Admission costs were quantified based on standardized actual cost/day. Admission cost greater than the median was defined as 'increased'. Of 458 elective CABG cases, 45 (10%) underwent pre-operative CMR. Pre-operative characteristics [mean (S.D.) age, 64 (9) years, mortality (1%) and median (interquartile range) admission duration, 7 (6–8) days] were similar in patients who did or did not undergo CMR. In the patients undergoing CMR, eight (18%) and 11 (24%) patients had reduced LV (left ventricular) systolic function by CMR [LVEF (LV ejection fraction) <55%] and echocardiography respectively. LE (late enhancement) with gadolinium was detected in 17 (38%) patients. The average cost/day was 2723.Themedian(interquartilerange)admissioncostwas2723. The median (interquartile range) admission cost was 19059 ($10891–157917). CMR LVEF {OR (odds ratio), 0.93 [95% CI (confidence interval), 0.87–0.99]; P=0.03} and SV (stroke volume) index [OR 1.07 (95% CI, 1.00–1.14); P=0.02] predicted increased admission cost. CMR LVEF (P=0.08) and EuroScore tended to predict actual admission cost (P=0.09), but SV by CMR (P=0.16) and LV function by echocardiography (P=0.95) did not. In conclusion, in this exploratory investigation, pre-operative CMR findings predicted admission duration and increased admission cost in elective CABG surgery. The cost-effectiveness of CMR in risk stratification in elective CABG surgery merits prospective assessment

    Lymphangiogenesis in myocardial remodelling after infarction

    Get PDF
    Ishikawa Y, Akishima-Fukasawa Y, Ito K, Akasaka Y, Tanaka M, Shimokawa R, Kimura-Matsumoto M, Morita H, Sato S, Kamata I & Ishii T (2007) Histopathology51, 345–35

    The biocompatibility of titanium in a buffer solution: compared effects of a thin film of TiO2 deposited by MOCVD and of collagen deposited from a gel

    Get PDF
    This study aims at evaluating the biocompatibility of titanium surfaces modified according two different ways: (i) deposition of a bio-inert, thin film of rutile TiO2 by chemical vapour deposition (MOCVD), and (ii) biochemical treatment with collagen gel, in order to obtain a bio-interactive coating. Behind the comparison is the idea that either the bio-inert or the bio-active coating has specific advantages when applied to implant treatment, such as the low price of the collagen treatment for instance. The stability in buffer solution was evaluated by open circuit potential (OCP) for medium time and cyclic voltametry. The OCP stabilized after 5104 min for all the specimens except the collagen treated sample which presented a stable OCP from the first minutes. MOCVD treated samples stabilized to more electropositive values. Numeric results were statistically analysed to obtain the regression equations for long time predictable evolution. The corrosion parameters determined from cyclic curves revealed that the MOCVD treatment is an efficient way to improve corrosion resistance. Human dermal fibroblasts were selected for cell culture tests, taking into account that these cells are present in all bio-interfaces, being the main cellular type of connective tissue. The cells grew on either type of surface without phenotype modification. From the reduction of yellow, water-soluble 3-(4,5-dimethyldiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT cytotoxicity test), MOCVD treated samples offer better viability than mechanically polished Ti and collagen treated samples as well. Cell spreading, as evaluated from microscope images processed by the program Sigma Scan, showed also enhancement upon surface modification. Depending on the experimental conditions, MOCVD deposited TiO2 exhibits different nanostructures that may influence biological behaviour. The results demonstrate the capacity of integration in simulated physiologic liquids for an implant pretreated by either method

    Quasimonoenergetic electron acceleration in the self-modulated laser wakefield regime

    Get PDF
    Details on the generation of (multiple) quasimonoenergetic electron bunches in the self-modulated laser wakefield acceleration (SMLWFA) regime are presented. This type of laser-plasma interaction can result in pronounced longitudinal laser pulse fragmentation, dependent on plasma density and laser intensity. It is shown by experiments and particle-in-cell simulations that these laser pulse fragments can be powerful enough to trigger nonlinear plasma wave breaking, injection, and acceleration of electrons to quasimonoenergetic energies. With high plasma densities, self-modulation is promoted, and the advantages of SMLWFA such as especially high accelerating fields and short electron bunches (<5 fs) can be harvested. In addition, more than one quasimonoenergetic electron bunch can be created, with a temporal spacing between each bunch of only few tens of femtoseconds, again governed by plasma density
    corecore