268 research outputs found
Recommended from our members
Contrast sensitivity and night driving in older people: Quantifying the relationship between visual acuity, contrast sensitivity, and hazard detection distance in a night-time driving simulator
Purpose: (i) To assess how well contrast sensitivity (CS) predicts night-time hazard detection distance (one key component of night driving ability), in normally sighted older drivers, relative to a conventional measure of high contrast visual acuity (VA); (ii) To evaluate whether CS can be accurately quantified within a night driving simulator.
Methods: Participants were fifteen (five female) ophthalmologically healthy adults, aged 55 to 81 years. CS was measured in a driving simulator using Landolt Cs, presented under static or dynamic driving conditions, and with or without glare. In the dynamic driving condition, the participant was asked to simultaneously maintain a (virtual) speed of 60 km/h on a country road. In the (dynamic) with glare condition, two calibrated LED arrays, moved by cable robots, simulated the trajectories and luminance characteristics of the (low beam) headlights of an approaching car. For comparison, CS was also measured clinically (with & without glare) using a Optovist I instrument (Vistec Inc., Olching/FRG). Visual acuity (VA) thresholds were also assessed at high and low contrast using the Freiburg Visual Acuity Test (FrACT) under photopic conditions. As a measure of driving performance, median hazard detection distance (MHDD) was computed, in meters, across three kinds of simulated obstacles of varying contrast.
Results: CS and low contrast VA were both significantly associated with driving performance (both P < 0.01), whereas conventional high contrast acuity was not (P = 0.10). There was good correlation (P < 0.01) between CS measured in the driving simulator and a conventional clinical instrument (Optovist). As expected, CS was shown to decrease in the presence of glare, in dynamic driving conditions, and as a function of age (all P < 0.01). Conclusions: CS and low contrast VA predict night-time hazard detection ability in a manner that conventional high contrast VA does not. Either may therefore provide a useful metric for assessing fitness to drive at night, particularly in older individuals. CS measurements can be made within a driving simulator, and the data are in good agreement with conventional clinical methods (Optovist I)
Reproducibility of pulmonary magnetic resonance angiography in adults with muco-obstructive pulmonary disease
Background
Recent studies support magnetic resonance angiography (MRA) as a diagnostic tool for pulmonary arterial disease.
Purpose
To determine MRA image quality and reproducibility, and the dependence of MRA image quality and reproducibility on disease severity in patients with chronic obstructive pulmonary disease (COPD) and cystic fibrosis (CF).
Material and Methods
Twenty patients with COPD (mean age 66.5 ± 8.9 years; FEV1% = 42.0 ± 13.3%) and 15 with CF (mean age 29.3 ± 9.3 years; FEV1% = 66.6 ± 15.8%) underwent morpho-functional chest magnetic resonance imaging (MRI) including time-resolved MRA twice one month apart (MRI1, MRI2), and COPD patients underwent non-contrast computed tomography (CT). Image quality was assessed visually using standardized subjective 5-point scales. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were measured by regions of interest. Disease severity was determined by spirometry, a well-evaluated chest MRI score, and by computational CT emphysema index (EI) for COPD.
Results
Subjective image quality was diagnostic for all MRA at MRI1 and MRI2 (mean score = 4.7 ± 0.6). CNR and SNR were 4 43.8 ± 8.7 and 50.5 ± 8.7, respectively. Neither image quality score nor CNR or SNR correlated with FEV1% or chest MRI score for COPD and CF (r = 0.239–0.248). CNR and SNR did not change from MRI1 to MRI2 (P = 0.434–0.995). Further, insignificant differences in CNR and SNR between MRA at MRI1 and MRI2 did not correlate with FEV1% nor chest MRI score in COPD and CF (r = −0.238–0.183), nor with EI in COPD (r = 0.100–0.111).
Conclusion
MRA achieved diagnostic quality in COPD and CF patients and was highly reproducible irrespective of disease severity. This supports MRA as a robust alternative to CT in patients with underlying muco-obstructive lung disease
Recommended from our members
Does intraocular straylight predict night driving visual performance? Correlations between straylight levels and contrast sensitivity, halo size, and hazard recognition distance with and without glare
Purpose: To evaluate the relationship between intraocular straylight perception and: (i) contrast sensitivity (CS), (ii) halo size, and (iii) hazard recognition distance, in the presence and absence of glare.
Subjects and methods: Participants were 15 (5 female) ophthalmologically healthy adults, aged 54.6–80.6 (median: 67.2) years. Intraocular straylight (log s) was measured using a straylight meter (C-Quant; Oculus GmbH, Wetzlar, Germany). CS with glare was measured clinically using the Optovist I device (Vistec Inc., Olching, Germany) and also within a driving simulator using Landolt Cs. These were presented under both static or dynamic viewing conditions, and either with or without glare. Hazard detection distance was measured for simulated obstacles of varying contrast. For this, the participant was required to maintain a speed of 60 km/h within a custom-built nighttime driving simulator. Glare was simulated by LED arrays, moved by cable robots to mimic an oncoming car’s headlights. Halo size (“halometry”) was measured by moving Landolt Cs outward originating from the center of a static glare source. The outcome measure from “halometry” was the radius of the halo (angular extent, in degrees visual angle).
Results: The correlation between intraocular straylight perception, log s, and hazard recognition distance under glare was poor for the low contrast obstacles (leading/subdominant eye: r = 0.27/r = 0.34). Conversely, log CS measured with glare strongly predicted hazard recognition distances under glare. This was true both when log CS was measured using a clinical device (Optovist I: r = 0.93) and within the driving simulator, under static (r = 0.69) and dynamic (r = 0.61) conditions, and also with “halometry” (r = 0.70). Glare reduced log CS and hazard recognition distance for almost all visual function parameters.
Conclusion: Intraocular straylight was a poor predictor of visual function and driving performance within this experiment. Conversely, CS was a strong predictor of both hazard recognition and halo extent. The presence of glare and motion lead to a degradation of CS in a driving simulator. Future studies are necessary to evaluate the effectiveness of all above-mentioned vision-related parameters for predicting fitness to drive under real-life conditions
Tower and Aircraft Eddy Covariance Measurements of Water Vapor, Energy, and Carbon Dioxide Fluxes during SMACEX
Abstract
A network of eddy covariance (EC) and micrometeorological flux (METFLUX) stations over corn (Zea mays L.) and soybean [Glycine max (L.) Merr.] canopies was established as part of the Soil Moisture–Atmosphere Coupling Experiment (SMACEX) in central Iowa during the summer of 2002 to measure fluxes of heat, water vapor, and carbon dioxide (CO2) during the growing season. Additionally, EC measurements of water vapor and CO2 fluxes from an aircraft platform complemented the tower-based measurements. Sensible heat, water vapor, and CO2 fluxes showed the greatest spatial and temporal variability during the early crop growth stage. Differences in all of the energy balance components were detectable between corn and soybean as well as within similar crops throughout the study period. Tower network–averaged fluxes of sensible heat, water vapor, and CO2 were observed to be in good agreement with area-averaged aircraft flux measurements
Entamoeba Shows Reversible Variation in Ploidy under Different Growth Conditions and between Life Cycle Phases
Under axenic growth conditions, trophozoites of Entamoeba histolytica contain heterogenous amounts of DNA due to the presence of both multiple nuclei and different amounts of DNA in individual nuclei. In order to establish if the DNA content and the observed heterogeneity is maintained during different growth conditions, we have compared E. histolytica cells growing in xenic and axenic cultures. Our results show that the nuclear DNA content of E. histolytica trophozoites growing in axenic cultures is at least 10 fold higher than in xenic cultures. Re-association of axenic cultures with their bacterial flora led to a reduction of DNA content to the original xenic values. Thus switching between xenic and axenic growth conditions was accompanied by significant changes in the nuclear DNA content of this parasite. Changes in DNA content during encystation-excystation were studied in the related reptilian parasite E. invadens. During excystation of E. invadens cysts, it was observed that the nuclear DNA content increased approximately 40 fold following emergence of trophozoites in axenic cultures. Based on the observed large changes in nuclear size and DNA content, and the minor differences in relative abundance of representative protein coding sequences, rDNA and tRNA sequences, it appears that gain or loss of whole genome copies may be occurring during changes in the growth conditions. Our studies demonstrate the inherent plasticity and dynamic nature of the Entamoeba genome in at least two species
Tube Models for Rubber-Elastic Systems
In the first part of the paper we show that the constraining potentials
introduced to mimic entanglement effects in Edwards' tube model and Flory's
constrained junction model are diagonal in the generalized Rouse modes of the
corresponding phantom network. As a consequence, both models can formally be
solved exactly for arbitrary connectivity using the recently introduced
constrained mode model. In the second part, we solve a double tube model for
the confinement of long paths in polymer networks which is partially due to
crosslinking and partially due to entanglements. Our model describes a
non-trivial crossover between the Warner-Edwards and the Heinrich-Straube tube
models. We present results for the macroscopic elastic properties as well as
for the microscopic deformations including structure factors.Comment: 15 pages, 8 figures, Macromolecules in pres
The Carboxy-Terminal Domain of Dictyostelium C-Module-Binding Factor Is an Independent Gene Regulatory Entity
The C-module-binding factor (CbfA) is a multidomain protein that belongs to the family of jumonji-type (JmjC) transcription regulators. In the social amoeba Dictyostelium discoideum, CbfA regulates gene expression during the unicellular growth phase and multicellular development. CbfA and a related D. discoideum CbfA-like protein, CbfB, share a paralogous domain arrangement that includes the JmjC domain, presumably a chromatin-remodeling activity, and two zinc finger-like (ZF) motifs. On the other hand, the CbfA and CbfB proteins have completely different carboxy-terminal domains, suggesting that the plasticity of such domains may have contributed to the adaptation of the CbfA-like transcription factors to the rapid genome evolution in the dictyostelid clade. To support this hypothesis we performed DNA microarray and real-time RT-PCR measurements and found that CbfA regulates at least 160 genes during the vegetative growth of D. discoideum cells. Functional annotation of these genes revealed that CbfA predominantly controls the expression of gene products involved in housekeeping functions, such as carbohydrate, purine nucleoside/nucleotide, and amino acid metabolism. The CbfA protein displays two different mechanisms of gene regulation. The expression of one set of CbfA-dependent genes requires at least the JmjC/ZF domain of the CbfA protein and thus may depend on chromatin modulation. Regulation of the larger group of genes, however, does not depend on the entire CbfA protein and requires only the carboxy-terminal domain of CbfA (CbfA-CTD). An AT-hook motif located in CbfA-CTD, which is known to mediate DNA binding to A+T-rich sequences in vitro, contributed to CbfA-CTD-dependent gene regulatory functions in vivo
Concomitant homozygosity for the prothrombin gene variant with mild deficiency of antithrombin III in a patient with multiple hepatic infarctions: a case report
<p>Abstract</p> <p>Introduction</p> <p>Hereditary causes of visceral thrombosis or thrombosis should be sought among young patients. We present a case of a young man presenting with multiple hepatic infarctions resulting in portal hypertension due to homozygosity of the prothrombin gene mutation not previously described in literature.</p> <p>Case presentation</p> <p>A 42-year-old Caucasian man with a previous history of idiopathic deep vein thrombosis 11 years earlier presented with vague abdominal pains and mildly abnormal liver function tests. An ultrasound and computed tomography scan showed evidence of hepatic infarction and portal hypertension (splenic varices). A thrombophilia screen confirmed a homozygous mutation for the prothrombin gene mutation, with mildly reduced levels of anti-thrombin III (AT III). Subsequent testing of his father and brother revealed heterozygosity for the same gene mutation.</p> <p>Conclusion</p> <p>Hepatic infarction is unusual due to the rich dual arterial and venous blood supply to the liver. In the absence of an arterial or haemodynamic insult causing hepatic infarction, a thrombophilia should be considered. To our knowledge, this is the first reported case of a hepatic infarction due to homozygosity of the prothrombin gene mutation. It is unclear whether homozygotes have a higher risk of thrombosis than heterozygotes. In someone presenting with a first thrombosis with this mutation, the case for life-long anticoagulation is unclear, but it may be necessary to prevent a second and more severe second thrombotic event, as occurred in this case.</p
Analysis of bacterial profiles of AGBRESA participants – a study concerning terrestrial astronauts under simulated microgravity
Introduction:
Long-term space missions are accompanied by harmful environmental conditions like
microgravity. Due to the reduced gravity, astronauts adapt to their environment resulting in
tissue fluidic shifts. Since the knowledge about microbiome data in space is sparse and
conduction of experiments at the ISS is complex, suitable analogs are needed. Therefore,
the first cooperative bed-rest study called Artificial Gravity Bed-Rest study with ESA
(AGBRESA), by NASA, ESA and DLR offered optimal features to investigate possible
correlations between microbial shifts and physiological microgravity by using -6° head-downtilt (HDT). The aim of this survey was to identify changes within the standardized conditions,
such as diet and wrongly distributed tissue fluids to reveal causal connections among health
state and microbial communities
Quantitative importance of staminodes for female reproductive success in Parnassia palustris under contrasting environmental conditions.
The five sterile stamens, or staminodes, in Parnassia palustris act both as false and as true nectaries. They attract pollinators with their conspicuous, but non-rewarding tips, and also produce nectar at the base. We removed staminodes experimentally and compared pollinator visitation rate and duration and seed set in flowers with and without staminodes in two different populations. We also examined the relative importance of the staminode size to other plant traits. Finally, we bagged, emasculated, and supplementary cross-pollinated flowers to determine the pollination strategy and whether reproduction was limited by pollen availability. Flowers in both populations were highly dependent on pollinator visitation for maximum seed set. In one population pollinators primarily cross-pollinated flowers, whereas in the other the pollinators facilitated self-pollination. The staminodes caused increased pollinator visitation rate and duration to flowers in both populations. The staminodes increased female reproductive success, but only when pollen availability constrained female reproduction. Simple linear regression indicated a strong selection on staminode size, multiple regression suggested that selection on staminode size was mainly caused by correlation with other traits that affected female fitness. [ABSTRACT FROM AUTHOR
- …