129 research outputs found

    Proton conduction in hydronium solvate ionic liquids affected by ligand shape

    Get PDF
    We investigated the ligand dependence of the proton conduction of hydronium solvate ionic liquids (ILs), consisting of a hydronium ion (H₃O⁺), polyether ligands, and a bis[(trifluoromethyl)sulfonyl]amide anion (Tf₂N⁻; Tf = CF₃SO₂). The ligands were changed from previously reported 18-crown-6 (18C6) to other cyclic or acyclic polyethers, namely, dicyclohexano-18-crown-6 (Dh18C6), benzo-18-crown-6 (B18C6) and pentaethylene glycol dimethyl ether (G5). Pulsed-field gradient spin echo nuclear magnetic resonance results revealed that the protons of H₃O⁺ move faster than those of cyclic 18C6-based ligands but as fast as those of acyclic G5 ligands. Based on these results and density functional theory calculations, we propose that the coordination of a cyclic ether ligand to the H₃O⁺ ion is essential for fast proton conduction in hydronium solvate ILs. Our results attract special interest for many electro- and bio-chemical applications such as electrolyte systems for fuel cells and artificial ion channels for biological cells

    Suppression of Fast Proton Conduction by Dilution of a Hydronium Solvate Ionic Liquid: Localization of Ligand Exchange

    Get PDF
    A dilution effect on the proton conduction of a hydronium solvate ionic liquid [H₃O⁺centerdot18C6]Tf₂N, which consists of hydronium ion (H₃O⁺), 18-crown-6-ether ligand (18C6), and bis[(trifluoromethyl)sulfonyl]amide anion (Tf₂N⁻; Tf = CF₃SO₂), has been studied. When [H₃O⁺・18C6]Tf₂N was diluted using equimolar 18C6 solvent, the distinctive fast proton conduction in [H₃O⁺・18C6]Tf₂N was suppressed in stark contrast to the case of common protic ionic liquids. Nuclear magnetic resonance spectroscopy showed that the fast exchange between free 18C6 molecules and coordinated ones, suggesting that the added solvent had induced a local proton exchange rather than a cooperative proton relay

    Cell-Surface Protein Profiling Identifies Distinctive Markers of Progenitor Cells in Human Skeletal Muscle

    Get PDF
    SummarySkeletal muscle contains two distinct stem/progenitor populations. One is the satellite cell, which acts as a muscle stem cell, and the other is the mesenchymal progenitor, which contributes to muscle pathogeneses such as fat infiltration and fibrosis. Detailed and accurate characterization of these progenitors in humans remains elusive. Here, we performed comprehensive cell-surface protein profiling of the two progenitor populations residing in human skeletal muscle and identified three previously unrecognized markers: CD82 and CD318 for satellite cells and CD201 for mesenchymal progenitors. These markers distinguish myogenic and mesenchymal progenitors, and enable efficient isolation of the two types of progenitors. Functional study revealed that CD82 ensures expansion and preservation of myogenic progenitors by suppressing excessive differentiation, and CD201 signaling favors adipogenesis of mesenchymal progenitors. Thus, cell-surface proteins identified here are not only useful markers but also functionally important molecules, and provide valuable insight into human muscle biology and diseases

    The outcomes of reconstruction using frozen autograft combined with iodine-coated implants for malignant bone tumors: Compared with non-coated implants

    Get PDF
    Objective: We perform reconstruction using frozen tumor bone treated by liquid nitrogen after excision of malignant bone tumors. To prevent post-operative infection, we use iodine-coated implants that we developed. The purpose of this study is to compare the outcome of reconstruction using frozen autograft with non-coated implants (group N) and iodine-coated implants (group I).Methods: Sixty-two patients were included in group N. The mean age was 31.9 ± 2.3 years. A total of 20 patients died and two were lost to follow-up, averaging 20.0 ± 2.9 months post-operatively, leaving 40 patients available for an assessment at a mean of 79.1 ± 5.8 months post-operatively. There were 38 patients in group I. The mean age was 29.8 ± 3.9 years. The mean follow-up period was 32.1 ± 3.0 months. All patients were alive at the latest follow-up. Survival of frozen bone was determined by Kaplan-Meier analysis.Results: In group N, survival of frozen bone was 80.7 ± 6.0% and 57.4 ± 10.2% at 5 and 10 years, respectively. Complications were encountered in 31 of 62 patients (50.0%), including deep infection in 10 (16.1%), fracture in 11 (17.7%), local soft-tissue recurrence in 6 (9.7%) and bone absorption in 4 (6.5%). In group I, survival of frozen bone was 86.7 ± 6.3% at 5 years. Complications were encountered in 8 of 38 patients (21.1%), including deep infection in one (2.6%), fracture in four (10.5%), local soft-tissue recurrence in two (5.3%) and bone absorption in one (2.6%). There was a significantly lower infection rate in group I (P = 0.032).Conclusion: Reconstruction using frozen autograft combined with iodine-coated implants for patients with malignant bone tumor is very useful method in which good limb function can be gained with minimized risk of infection. © The Author 2016. Published by Oxford University Press. All rights reserved.Article number hyw065 / Embargo Period 6 month

    A report of a pilot implementation of Tutorial English classes at the Faculty of Safety Science : a two-part survey based on questionnaire-results

    Get PDF
    This paper summarizes participants\u27 evaluations of the Tutorial English course offered by Waseda University International Corporation, as a part of a pilot English program being considered by the Faculty of Safety Science, and implemented from February 21 to March 5, 2011. The first part presents the results for the Tutorial English course in particular, with the second part showing those for learning in orthodox English courses. Both sets of results were obtained by means of questionnaires administered to the students participating

    OryzaExpress: An Integrated Database of Gene Expression Networks and Omics Annotations in Rice

    Get PDF
    Similarity of gene expression profiles provides important clues for understanding the biological functions of genes, biological processes and metabolic pathways related to genes. A gene expression network (GEN) is an ideal choice to grasp such expression profile similarities among genes simultaneously. For GEN construction, the Pearson correlation coefficient (PCC) has been widely used as an index to evaluate the similarities of expression profiles for gene pairs. However, calculation of PCCs for all gene pairs requires large amounts of both time and computer resources. Based on correspondence analysis, we developed a new method for GEN construction, which takes minimal time even for large-scale expression data with general computational circumstances. Moreover, our method requires no prior parameters to remove sample redundancies in the data set. Using the new method, we constructed rice GENs from large-scale microarray data stored in a public database. We then collected and integrated various principal rice omics annotations in public and distinct databases. The integrated information contains annotations of genome, transcriptome and metabolic pathways. We thus developed the integrated database OryzaExpress for browsing GENs with an interactive and graphical viewer and principal omics annotations (http://riceball.lab.nig.ac.jp/oryzaexpress/). With integration of Arabidopsis GEN data from ATTED-II, OryzaExpress also allows us to compare GENs between rice and Arabidopsis. Thus, OryzaExpress is a comprehensive rice database that exploits powerful omics approaches from all perspectives in plant science and leads to systems biology

    Prevention of hypoglycemia by intermittent-scanning continuous glucose monitoring device combined with structured education in patients with type 1 diabetes mellitus : A randomized, crossover trial

    Get PDF
    Aims: We conducted a randomized, crossover trial to compare intermittent-scanning continuous glucose monitoring (isCGM) device with structured education (Intervention) to self-monitoring of blood glucose (SMBG) (Control) in the reduction of time below range. Methods: This crossover trial involved 104 adults with type 1 diabetes mellitus (T1DM) using multiple daily injections. Participants were randomly allocated to either sequence Intervention/Control or sequence Control/Intervention. During the Intervention period which lasted 84 days, participants used the first-generation FreeStyle Libre (Abbott Diabetes Care, Alameda, CA, USA) and received structured education on how to prevent hypoglycemia based on the trend arrow and by frequent sensor scanning (≥10 times a day). Confirmatory SMBG was conducted before dosing insulin. The Control period lasted 84 days. The primary endpoint was the decrease in the time below range (TBR; <70 mg/dL). Results: The time below range was significantly reduced in the Intervention arm compared to the Control arm (2.42 ± 1.68 h/day [10.1 %±7.0 %] vs 3.10 ± 2.28 h/day [12.9 %±9.5 %], P = 0.012). The ratio of high-risk participants with low blood glucose index >5 was significantly reduced (8.6 % vs 23.7 %, P < 0.001). Conclusions: The use of isCGM combined with structured education significantly reduced the time below range in patients with T1DM

    Ultra-High-Resolution Computed Tomography of the Lung: Image Quality of a Prototype Scanner

    Get PDF
    Purpose: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. Materials and Methods: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm × 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm × 16 or 0.5 mm × 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. Results: The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P <.0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P <.0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary ves sels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. Conclusion: Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners
    corecore