111 research outputs found

    Econometric modelling of enterprise financial activity

    Get PDF
    The article considers specific features of application of vector auto-regression technologies and models of error correcting in the study of strategic financial position of an enterprise. It offers an algorithm of selection of the method of forecasting interconnected financial indicators. It develops dynamic systems of indicators of external and internal financial environment of an enterprise. The obtained results could be used in strategic management of the enterprise financial activity

    УЧЕТ ИЗМЕНЕНИЯ ИНТЕНСИВНОСТИ ПУЧКА СИНХРОТРОННОГО ИЗЛУЧЕНИЯ ПРИ РЕГИСТРАЦИИ СПЕКТРОВ БИОЛОГИЧЕСКИХ ОБРАЗЦОВ МЕТОДОМ РФА-СИ

    Get PDF
    The present work shows the results of an experiment aimed to evaluate the influence of storage ring current decrease on metrological characteristics of X-ray fluorescent analysis with synchrotron radiation of thin samples with biological matrix. It was shown experimentally that Compton peak normalization of the characteristic peak square сan be used not only to take into account sampling procedure differences (geometry and thickness of the samples) but also to take account of the decrease of the excitation radiation intensity. Key words: X-ray fluorescence analysis, synchrotron radiation, biological standards, evaluation procedure. (Russian)DOI: http://dx.doi.org/10.15826/analitika.2013.17.1.001 A.V. Sidorina, V.A. Trunova A. V. Nikolaev Institute of Inorganic chemistry SB RAS, Novosibirsk, Russian FederationПриведены результаты эксперимента по оценке влияния падения тока накопительного кольца на метрологические характеристики рентгенофлуоресцентного анализа с использованием синхротронного излучения при анализе тонких образцов с биологической матрицей. Экспериментально показано, что нормировка площади пика характеристического излучения на площадь пика комптоновского рассеяния может использоваться не только для учета различий в пробоподготовке тонких биообразцов тканей (по геометрии и толщине), но и для учета снижения интенсивности возбуждающего излучения. Ключевые слова: рентгенофлуоресцентный анализ, синхротронное излучение, биологические стандартные образцы, способ количественной обработки результатов. DOI: http://dx.doi.org/10.15826/analitika.2013.17.1.001

    Rare case of type II glycogen storage disease

    Get PDF
    The article presents information about a rare case of Pompe disease. It is a glycogen storage disease. During the third screening of a pregnant woman, the ultrasonography of the fetus’s heart revealed the myocardial hypertrophy of the left ventricle perceived as posthypoxic. After delivery, the newborn underwent the ultrasound examination and molecular genetic studies. Firstly, the hepatomegaly and cardiomegaly were diagnosed. Then an infantile form of Pompe disease was found. The patient got enzyme replacement therapy without positive result. The death occurred at the age of 2 years and 5 months as a result of cardiovascular disease failure. Macroscopically, the sizes of the internal organs were increased. The microscopic examination demonstrated glycogen deposition in the myocardium, skeletal muscles, mucous membranes of the organs of the gastrointestinal tract, liver, kidney, spleen and adrenal gland

    Application of the Theory of Continuous Markov Chains in Determining Changes in the Status of Production Systems

    Get PDF
    В статті запропоновані шляхи адаптації існуючих математичних методів до сучасної практики управління, зокрема визначення зміни станів виробничої системи із застосуванням апарату теорії неперервних Марківських ланцюгів. У зв'язку з великим обсягом обчислювальних процедур при вирішенні таких завдань (обчислення визначника, перетворення матриць, множення матриць, знаходження власних векторів і власних чисел і т. д.) розглядається методика їх розв’язання на ЕОМ. В якості програмного забезпечення використано пакет MathCAD. Зокрема, описані особливості введення, виведення даних та інтерпретації результатів, що становить значний інтерес для користувачів в умовах застосування англійських версій програмного забезпечення. При використанні пакету MathCAD додатково можна досліджувати стійкість розв’язку системи диференціальних рівнянь Колмогорова, що надає змогу визначити фінальні ймовірності - середній час перебування системи в відповідному стані. Запропоновані задачі можуть бути використані для проведення практичних занять з розділу «Випадкові процеси» курсу теорії ймовірностей та математичної статистики, а також для моделювання виробничо-економічних, бюджетно- фінансових та інших стохастичних систем в процесі виконання курсових і дипломних робіт майбутніми економістами.The paper suggests ways to adapt existing mathematical methods in modern management practices, in particular the determination of changes in the state of the production system using the apparatus of the theory of continuous Markov chains. Due to the large amount of computational procedures when performing such tasks (calculation of the determinant of transformation matrices, matrix multiplication, finding the eigenvectors and eigenvalues and etc.) the technique to solve them on a computer. As the software used MathCAD package. In particular, it describes the features of the input, the output and the interpretation of results, which is of considerable interest to users under the conditions of use of the English versions of the software. When using of MathCAD can further investigate the stability of the system of differential equations of Kolmogorov, which makes it possible to determine the probability of the final - the average residence time in the appropriate system status. The proposed tasks can was used for practical training under the heading "Random Processes" course of probability theory and mathematical statistics, as well as to simulate production and economic, fiscal, and other stochastic systems in the implementation of projects and dissertations of future economists

    The evaluation of the direct SRXRF analysis applicability on the small biological samples

    Full text link
    Возможность прямого анализа цельных образцов биологической ткани малой массы является неоспоримым достоинством метода рентгенофлуоресцентного анализа с использованием синхротронного излучения (РФА-СИ). Метод РФА-СИ реализован на базе ИЯФ СО РАН в Сибирском центре синхротронного и терагерцового излучения. В данной работе анализировали цельные образцы печени, высушенные в виде пластинок плоско-параллельной формы. Известно, что минимизация процедур пробоподготовки сокращает потери и уровень загрязнений образца. Предложенный способ пробоподготовки исключал лиофильную сушку, растирание и прессование материала. Концентрации химических элементов в исследуемых образцах определяли по градуировочному графику, построенному на основе ряда биологических стандартных образцов. Результаты эксперимента показали, что концентрации определяемых химических элементов в случае прямого анализа плоско-параллельного фрагмента биоткани (печени) и в случае растирания того же образца (и приготовления из него таблеток) достоверно не различались. Для оценки воспроизводимости результатов измерений и неоднородности распределения химических элементов два цельных и один растертый образец печени были последовательно измерены по 5 раз. Проверка правильности полученных методом РФА-СИ результатов была проведена путем сравнения с данными, полученными другим независимым методом - атомно-эмиссионной спектроскопией с двухструйным дуговым плазмотроном (ДДП-АЭС). Предложенный нами способ пробоподготовки может применяться для анализа биотканей малой массы по способу внешнего стандарта.The direct analysis of the biological tissue samples is a great advantage of the X-ray Fluorescent Technique with Synchrotron Radiation (SRXRF). SRXRF method is realized on the basis of INP SB RAS in Siberian Synchrotron and Terahertz Radiation Centre. In the present work, the whole liver tissue samples were dried under weight and analyzed in the form of parallel-plane fragments. The minimization of sample preparation procedures is known to significantly reduce the risks of the sample contamination and loss of analyte. The preparation procedure, which was used in the present work, was carried out without lyophilization, grinding and pelletizing of liver tissue samples. Elemental concentrations in the samples were calculated using the calibration and constructed on the basis of biological certified reference materials. It was found that there weren’t any significant differences between elemental concentrations in the case of the direct analysis of parallel-plane liver fragments and concentrations obtained for the same liver samples after grinding and pelletizing. Two unbroken samples and one grinded sample were measured 5 times to assess the reproducibility. The relative standard deviation for each sample was calculated, and it included both the assessment of the reproducibility and the heterogeneity of the elemental distribution in the sample. The validation of the results obtained by SRXRF method was estimated by the comparison with the results obtained by another method, namely by Two-Jet Plasma Atomic Emission Spectrometry (TJP-AES). Thereby the offered way of sample preparation procedure using external standard method for calculation of elemental concentrations can be applied for SRXRF analysis of biological samples

    Аналіз застосування методики оцінки технічного стану розподільних мереж

    Get PDF
    The article deals with the issues of practical application of the technique of estimation of the technical state of distribution networks with voltage 0,38-20 kV with overhead transmission lines. It is based on the fixing by the operating personnel of defects in the equipment of distribution network objects (overhead lines and transformer substations). However, not all defects from the recommended list for fixing the list are listed always, but only those that require immediate removal. Accordingly, there is a need to determine how much this may affect the result of further analysis of the technical state of distribution networks. Since the calculations of the qualitative and quantitative assessment of the technical state of distribution networks are based on the processing of a large body of power equipment inspection data and are quite time-consuming, it requires the use of computer technologies. Therefore, block diagrams of the algorithms of qualitative and quantitative assessment of the technical state of the objects of distribution networks (overhead transmission lines and transformer substations) were developed. Using the flowcharts of the calculation algorithms, computer programs for estimating the technical state of distribution networks 0.38-20 kV with overhead transmission lines have been developed. They made it possible to analyze possible errors in the calculations for different variants of operations of the operating personnel. Research results have been obtained that conclude that the actions of the operating personnel in the process of creating an array of data on defects in the equipment of distribution network facilities are a significant factor in influencing the final result of the analysis of the technical state of the distribution networks.В статті розглядаються питання практичного застосування методики оцінки технічного стану розподільних мереж напругою 0,38-20 кВ з повітряними лініями електропередачі. В її основі – фіксація експлуатаційним персоналом дефектів обладнання об’єктів розподільних мереж (повітряних ліній та трансформаторних підстанцій). При цьому, не завжди до листка огляду заносяться усі дефекти з рекомендованого для фіксації переліку, а лише ті, що вимагають усунення негайно. Відповідно, виникає необхідність визначення, на скільки це може вплинути на результат подальшого аналізу технічного стану розподільних мереж. Так як розрахунки якісної та кількісної оцінки технічного стану розподільних мереж базуються на обробці великого масиву даних оглядів енергетичного обладнання та є досить трудомісткими, то це вимагає застосування комп’ютерних технологій. Тому були розроблені блок-схеми алгоритмів якісної та кількісної оцінки технічного стану об’єктів розподільних мереж (повітряних ліній електропередачі та трансформаторних підстанцій). Використовуючи блок-схеми алгоритмів розрахунків, розроблені комп’ютерні програми оцінки технічного стану розподільних мереж напругою 0,38-20 кВ з повітряними лініями електропередачі. Вони дозволили проаналізувати можливі похибки в розрахунках при різних варіантах дій експлуатаційного персоналу. Були отримані результати досліджень, які дозволяють зробити висновок, що дії експлуатаційного персоналу в процесі створення масиву даних щодо дефектів обладнання об’єктів розподільних мереж є суттєвим фактором впливу на кінцевий результат аналізу технічного стану розподільних мереж.&nbsp

    ОЦЕНКА ВОЗМОЖНОСТИ ПРИМЕНЕНИЯ ПРЯМОГО АНАЛИЗА ОБРАЗЦОВ БИОТКАНЕЙ МАЛОЙ МАССЫ МЕТОДОМ РЕНТГЕНФЛУОРЕСЦЕНТНОГО АНАЛИЗА С СИНХРОТРОННЫМ ВОЗБУЖДЕНИЕМ

    Get PDF
    The direct analysis of the biological tissue samples is a great advantage of the X-ray Fluorescent Technique with Synchrotron Radiation (SRXRF). SRXRF method is realized on the basis of INP SB RAS in Siberian Synchrotron and Terahertz Radiation Centre. In the present work, the whole liver tissue samples were dried under weight and analyzed in the form of parallel-plane fragments. The minimization of sample preparation procedures is known to significantly reduce the risks of the sample contamination and loss of analyte. The preparation procedure, which was used in the present work, was carried out without lyophilization, grinding and pelletizing of liver tissue samples. Elemental concentrations in the samples were calculated using the calibration and constructed on the basis of biological certified reference materials. It was found that there weren’t any significant differences between elemental concentrations in the case of the direct analysis of parallel-plane liver fragments and concentrations obtained for the same liver samples after grinding and pelletizing. Two unbroken samples and one grinded sample were measured 5 times to assess the reproducibility. The relative standard deviation for each sample was calculated, and it included both the assessment of the reproducibility and the heterogeneity of the elemental distribution in the sample. The validation of the results obtained by SRXRF method was estimated by the comparison with the results obtained by another method, namely by Two-Jet Plasma Atomic Emission Spectrometry (TJP-AES). Thereby the offered way of sample preparation procedure using external standard method for calculation of elemental concentrations can be applied for SRXRF analysis of biological samples.         Keywords: x-ray fluorescent analysis, synchrotron radiation, sample preparation, biological tissue, liver(Russian)DOI: http://dx.doi.org/10.15826/analitika.2015.19.2.008 V.A. Trunova1,2, A.V. Sidorina1, V.V. Zvereva1 1A.V. Nikolaev Institute of Inorganic Сhemistry SB RAS, Novosibirsk, Russian Federation2Novosibirsk State University, Novosibirsk, Russian FederationВозможность прямого анализа цельных образцов биологической ткани малой массы является неоспоримым достоинством метода рентгенофлуоресцентного анализа с использованием синхротронного излучения (РФА-СИ). Метод РФА-СИ реализован на базе ИЯФ СО РАН в Сибирском центре синхротронного и терагерцового излучения. В данной работе анализировали цельные образцы печени, высушенные в виде пластинок плоско-параллельной формы. Известно, что минимизация процедур пробоподготовки сокращает потери и уровень загрязнений образца. Предложенный способ пробоподготовки исключал лиофильную сушку, растирание и прессование материала. Концентрации химических элементов в исследуемых образцах определяли по градуировочному графику, построенному на основе ряда биологических стандартных образцов. Результаты эксперимента показали, что концентрации определяемых химических элементов в случае прямого анализа плоско-параллельного фрагмента биоткани (печени) и в случае растирания того же образца (и приготовления из него таблеток) достоверно не различались. Для оценки воспроизводимости результатов измерений и неоднородности распределения химических элементов два цельных и один растертый образец печени были последовательно измерены по 5 раз. Проверка правильности полученных методом РФА-СИ результатов была проведена путем сравнения с данными, полученными другим независимым методом ‒ атомно-эмиссионной спектроскопией с двухструйным дуговым плазмотроном (ДДП-АЭС). Предложенный нами способ пробоподготовки  может применяться для анализа биотканей малой массы по способу внешнего стандарта.         Ключевые слова: рентгенофлуоресцентный анализ, синхротронное излучение, пробоподготовка, биологические ткани, печеньDOI: http://dx.doi.org/10.15826/analitika.2015.19.2.00

    Влияние экологических факторов на развитие рыбного хозяйства Украины

    Get PDF
    Аквакультура становится одной из наиболее перспективных отраслей сельского хазяйства. При рациональном использовании водных ресурсов можно обеспечить потребителей качественной, безопасной и полезной продукцией широкого ассортимента. Современное использование водных ресурсов для ведения аквакультуры базируется на принципе обязательного сохранения их естественного воспроизводства

    Poly[[diaqua[μ5-(R,S)-2-({2-[(1,2-di­carboxyl­atoeth­yl)amino]­eth­yl}amino)­butane­dioato]cobaltate(III)sodium] di­hydrate]

    Get PDF
    In the asymmetric unit of the title coordination polymer, {[CoNa(C10H12N2O8)(H2O)2]·2H2O}n, the CoII ion is coord­inated in a distorted octa­hedral environment, defined by two N atoms and four carboxyl­ate O atoms. Two CoII ions and two 2-({2-[(1,2-dicarboxyl­atoeth­yl)amino]­eth­yl}amino)­butane­dio­ate (EDDS) ligands form a dimeric complex dianion [Co2(EDDS)2]. These dimeric units are connected via Na+ ions, forming a three-dimensional polymeric structure. In the crystal, the ligand N—H groups and the coordinated and solvent water mol­ecules are involved in inter­molecular N—H⋯O and O—H⋯O hydrogen bonding, reinforcing the three-dimensional polymeric structure

    Microwave study of the effect of cold argon plasma on functional state of rat’s skin

    Get PDF
    The purpose of this study was a comparative study of the dielectric parameters of rat skin when treated with argon and argon cold plasma. The experiment was performed on 40 male Wistar rats divided into 4 equal groups. The first group of animals (n=10) was a control (intact). The rats of the remaining groups (n=10 in each) were treated daily with a pre-epilated area of the skin of the back (area = 1x1 cm). The duration of the course for all experienced groups is 10 procedures. Animals of the second group were treated with a non–ionized argon stream (the duration of one procedure was 1 minute), rats of the third and fourth groups were treated with argon cold plasma (1 and 2 minutes, respectively). Cold plasma generation was performed using a device using the principle of microwave ionization of a gas stream. Argon of high purity (99.99%) was used as the latter. The dielectric parameters of the skin of animals in the treated area (in control group rats – at a similar point in the back) were evaluated upon completion of a full course of exposure. For this purpose, a specialized software and hardware complex was used, providing near-field resonant microwave probing of biological tissues. It was found that the course treatment of the skin of the back of rats with gas streams with different ionization causes the formation of a specific functional-metabolic and morpho-structural response. Its character is determined by the parameters of the gas flow used: non-ionized argon significantly reduces the dielectric parameters (permeability and conductivity), and the result of the action of cold argon plasma depends on the exposure. During one-minute treatment, tissue permeability was observed to remain intact with a moderate decrease in conductivity. In the case of an increase in the exposure time to 2 minutes, the dielectric constant increased, and the conductivity remained unchanged
    corecore