8 research outputs found

    Effect of a Perioperative, Cardiac Output-Guided Hemodynamic Therapy Algorithm on Outcomes Following Major Gastrointestinal Surgery A Randomized Clinical Trial and Systematic Review

    Get PDF
    Importance: small trials suggest that postoperative outcomes may be improved by the use of cardiac output monitoring to guide administration of intravenous fluid and inotropic drugs as part of a hemodynamic therapy algorithm.Objective: to evaluate the clinical effectiveness of a perioperative, cardiac output–guided hemodynamic therapy algorithm.Design, setting, and participants: OPTIMISE was a pragmatic, multicenter, randomized, observer-blinded trial of 734 high-risk patients aged 50 years or older undergoing major gastrointestinal surgery at 17 acute care hospitals in the United Kingdom. An updated systematic review and meta-analysis were also conducted including randomized trials published from 1966 to February 2014.Interventions: patients were randomly assigned to a cardiac output–guided hemodynamic therapy algorithm for intravenous fluid and inotrope (dopexamine) infusion during and 6 hours following surgery (n=368) or to usual care (n=366).Main outcomes and measures: the primary outcome was a composite of predefined 30-day moderate or major complications and mortality. Secondary outcomes were morbidity on day 7; infection, critical care–free days, and all-cause mortality at 30 days; all-cause mortality at 180 days; and length of hospital stay.Results: baseline patient characteristics, clinical care, and volumes of intravenous fluid were similar between groups. Care was nonadherent to the allocated treatment for less than 10% of patients in each group. The primary outcome occurred in 36.6% of intervention and 43.4% of usual care participants (relative risk [RR], 0.84 [95% CI, 0.71-1.01]; absolute risk reduction, 6.8% [95% CI, ?0.3% to 13.9%]; P?=?.07). There was no significant difference between groups for any secondary outcomes. Five intervention patients (1.4%) experienced cardiovascular serious adverse events within 24 hours compared with none in the usual care group. Findings of the meta-analysis of 38 trials, including data from this study, suggest that the intervention is associated with fewer complications (intervention, 488/1548 [31.5%] vs control, 614/1476 [41.6%]; RR, 0.77 [95% CI, 0.71-0.83]) and a nonsignificant reduction in hospital, 28-day, or 30-day mortality (intervention, 159/3215 deaths [4.9%] vs control, 206/3160 deaths [6.5%]; RR, 0.82 [95% CI, 0.67-1.01]) and mortality at longest follow-up (intervention, 267/3215 deaths [8.3%] vs control, 327/3160 deaths [10.3%]; RR, 0.86 [95% CI, 0.74-1.00]).Conclusions and relevance: in a randomized trial of high-risk patients undergoing major gastrointestinal surgery, use of a cardiac output–guided hemodynamic therapy algorithm compared with usual care did not reduce a composite outcome of complications and 30-day mortality. However, inclusion of these data in an updated meta-analysis indicates that the intervention was associated with a reduction in complication rate

    Characterisation of carbon paste electrodes for real-time amperometric monitoring of brain tissue oxygen.

    Get PDF
    Tissue O₂ can be monitored using a variety of electrochemical techniques and electrodes. In vitro and in vivo characterisation studies for O₂ reduction at carbon paste electrodes (CPEs) using constant potential amperometry (CPA) are presented. Cyclic voltammetry indicated that an applied potential of -650 mV is required for O₂ reduction at CPEs. High sensitivity (-1.49 ± 0.01 nA/μM), low detection limit (ca. 0.1 μM) and good linear response characteristics (R² > 0.99) were observed in calibration experiments performed at this potential. There was also no effect of pH, temperature, and ion changes, and no dependence upon flow/fluid convection (stirring). Several compounds (e.g. dopamine and its metabolites) present in brain extracellular fluid were tested at physiological concentrations and shown not to interfere with the CPA O₂ signal. In vivo experiments confirmed a sub-second response time observed in vitro and demonstrated long-term stability extending over twelve weeks, with minimal O₂ consumption (ca. 1 nmol/h). These results indicate that CPEs operating amperometrically at a constant potential of -650 mV (vs. SCE) can be used reliably to continuously monitor brain extracellular tissue O₂
    corecore