1,269 research outputs found

    Model for Determining Geographical Distribution of Heat Saving Potentials in Danish Building Stock

    Get PDF
    Since the global oil crisis in the 1970s, Denmark has followed a path towards energy independency by continuously improving its energy efficiency and energy conservation. Energy efficiency was mainly tackled by introducing a high number of combined heat and power plants in the system, while energy conservation was predominantly approached by implementing heat saving measures. Today, with the goal of 100% renewable energy within the power and heat sector by the year 2035, reductions in energy demand for space heating and the preparation of domestic hot water remain at the top of the agenda in Denmark. A highly detailed model for determining heat demand, possible heat savings and associated costs in the Danish building stock is presented. Both scheduled and energy-saving renovations until year 2030 have been analyzed. The highly detailed GIS-based heat atlas for Denmark is used as a container for storing data about physical properties for 2.5 million buildings in Denmark. Consequently, the results of the analysis can be represented on a single building level. Under the assumption that buildings with the most profitable heat savings are renovated first, the consequences of heat savings for the economy and energy system have been quantified and geographically referenced. The possibilities for further improvements of the model and the application to other geographical regions have been discussed

    Temperature and inoculation method influence disease phenotypes and mortality of Eucalyptus marginata clonal lines inoculated with Phytophthora cinnamomi

    Get PDF
    Survival of 1-year-old plants of three clonal lines of Eucalyptus marginata (jarrah), two ranked as resistant (RR1 and RR2) and one as susceptible (SS1) to Phytophthora cinnamomi, was assessed after pathogen inoculation with either mycelial mats underbark or zoospores on the stem. Plants were grown at 15, 20, 25 and 30°C. Method of inoculation did not produce comparable mortalities of the clonal lines, particularly at 25 and 30°C. At these temperatures, all three clonal lines had 100% mortality when inoculated underbark, but when inoculated with zoospores, RR1 had 60% survival and lines SS1 and RR2 had 100% mortality. Generally, the level of resistance of all clonal lines declined with increasing temperature. RR2 had consistently higher mortality than SS1, and is therefore not considered resistant. Lesion development was also measured in detached stems of RR1 and a susceptible clonal line (SS2) each inoculated underbark with four different P. cinnamomi isolates. Stems were assessed for lesion development at 20, 25 and 30°C for 4 days. For all four isolates, detached stems of RR1 generally had smaller lesions than those of SS2, particularly at 30°C. The increase in lesion length with increasing temperature was greatest for SS2. Detached stems may have potential in screening for jarrah resistant toP. cinnamomi and allow identification of susceptible clonal lines at 30°C

    Energirenovering af murermesterhus

    Get PDF

    Trans fat intake and risk of lifestyle diseases

    Get PDF

    Measurement results and experiences from an energy renovation of a typical Danish single-family house

    Get PDF
    Energy renovation of existing buildings has a large potential for cost effective energy savings. However, it is a major challenge to develop and implement the technologies for reducing the energy use in existing buildings to a very low level in combination with renovation of the buildings. To demonstrate how it could be done in small residential buildings a thorough retrofitting of a single-family house from 1972 was carried out. The house was brought up to the energy performance level of a new house. The energy renovation has reduced the net room heating consumption from 27.8 to 12.7 MWh/year corresponding to a 54 % reduction. The energy renovation project has proven that it is possible to renovate a typical Danish single-family house from the 1960/70’s in a cost efficient manner to roughly the energy performance standard of a new Danish single-family house. As a positive side effect the living conditions have been greatly improved. In the paper the author also describes the lessons learned during the process of renovating the house
    • …
    corecore