5 research outputs found

    Flor ilave edilmiş itriyum hidroksiapatitin mikroyapı, mikrosertlik ve biyouyumluluk özelliklerinin incelenmesi.

    Get PDF
    The aim of this study was to investigate the microstructure, microhardness and biocompatibility properties of nano hydroxyapatite (HA) doped with a constant yttrium (Y3+) and varying fluoride (F-) compositions. HA was synthesized via precipitation method and sintered at 1100C for 1 hour. Increased densities were achieved upon Y3+ doping while F- doping led to a decrease in densities. For structural analysis, XRD, SEM and FTIR spectroscopy examinations were performed. No secondary phases were observed in XRD studies upon doping. Lattice parameters decreased due to substitutions of ions. In SEM analysis, addition of doping ions was observed to result in smaller grains. In FTIR analysis, in addition to the characteristic bands of HA, novel bands indicating the substitution of F- ions were observed in F- ion doped samples. The highest microhardness value was obtained for the sample doped with 2.5%Y3+, 1%F-. Increased F- ion contents resulted in decreased microhardness values. For biocompatibility evaluation, in vitro tests were applied to the materials. MTT assay was performed for Saos-2 cell proliferation analysis. Y3+ and F- ion incorporation was found to improve cell proliferation on HA discs. Cells were found to attach and proliferate on disc surfaces in SEM analysis. ALP assay showed differentiation of cells on the discs can be improved by doping HA with an optimum amount of F- ion. Dissolution tests in DMEM revealed that structural stability of HA was improved with F- ion incorporation. The material exhibiting optimum structural, mechanical and biocompatibility properties was HA doped with 2.5%Y3+, 1%F-.M.S. - Master of Scienc

    Mikrodeformasyon ile Yüzey Özellikleri Değiştirilen 316L Paslanmaz Çeliğin Sentetik Vücut Sıvısı ile Etkileşimi

    Get PDF
    Bu çalışmada ortopedik uygulamalarda yaygın olarak kullanılan bir biyomedikal alaşım olan 316L paslanmaz çelik yüzeyinde mikro sertlik ölçüm cihazı kullanılarak mikrodeformasyon alanları oluşturulmuş ve elde edilen farklı yüzey desenlerinin biyouyumluluğa etkisi sentetik vücut sıvısı içi statik daldırma deneyleri ile test edilmiştir. 7 ve 21 günlük daldırma periyotlarının ardından örnek yüzeyleri oksit ve kalsiyum-fosfatlı yapıların çökelmesi, sıvılar ise iyon salımı açısından incelendiğinde, her iki açıdan da oluşturulan farklı mikrodeformasyon desenlerinin kontrol numunesine kıyasla iyileştirme sağladığı saptanıştır. Oluşturulan desenler arasında ise iz boyutu büyük, izler arası mesafesi geniş olan paternin optimum özellikleri sağlayan yüzey olduğu gözlenmiştir. Yüzey pürüzlülüğü ve sıvı içi oksit ve kalsiyum-fosfatlı yapıların çökelmesi arasında bir doğru orantı tespit edilememiş, bu da yüzey enerjisini belirlemede mikrodeformasyonun mikroyapısal mekanizmalar üzerindeki etkisinin daha belirleyici olabileceğine dair ön bulgular ortaya koymuştur

    Nickel ion release and surface analyses on instrument fragments fractured beyond the apex: a laboratory investigation

    No full text
    Abstract Background To analyse the changes in surface and nickel ion release characteristics of fractured root canal shaping instruments in a simulated body fluid environment. Methods A total of 54 new instruments were studied. The instrument groups consisted of five different NiTi alloys and a stainless-steel alloy. To standardize instrument fracture, a torsional type of failure was created on each instrument. The fractured specimens of each instrument group were randomly divided into three static immersion subgroups of 1 h, 7-day, and 30-day (n = 3). Simulated body fluid (SBF) was prepared to mimic human blood plasma by Kokubo&Takadama protocol for ex situ static immersions at 37ºC. The surfaces were examined via scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy. To determine the quantitative ion release, the retrieved SBFs were analyzed using inductively coupled plasma mass spectrometry. Two-way ANOVA and Tukey post hoc tests sought the statistical significance of the nickel ion values(p  0.05). Conclusions Within the limitations of the presented study, it was concluded that the fractured SS and NiTi root canal instruments release Ni ions in contact with body fluid. However, the Ni ion release values determined during the observation periods are lower than the critical toxic or allergic thresholds defined for the human body. This was due to the ionic dissolution cycle reaching a stable state from 1-hour to 30-day exposure to the body fluid of fractured instruments

    Mikrodeformasyon ile Yüzey Özellikleri Değiştirilen 316L Paslanmaz Çeliğin Sentetik Vücut Sıvısı ile Etkileşimi

    No full text
    Bu çalışmada ortopedik uygulamalarda yaygın olarak kullanılan bir biyomedikal alaşım olan 316L paslanmaz çelik yüzeyinde mikro sertlik ölçüm cihazı kullanılarak mikrodeformasyon alanları oluşturulmuş ve elde edilen farklı yüzey desenlerinin biyouyumluluğa etkisi sentetik vücut sıvısı içi statik daldırma deneyleri ile test edilmiştir. 7 ve 21 günlük daldırma periyotlarının ardından örnek yüzeyleri oksit ve kalsiyum-fosfatlı yapıların çökelmesi, sıvılar ise iyon salımı açısından incelendiğinde, her iki açıdan da oluşturulan farklı mikrodeformasyon desenlerinin kontrol numunesine kıyasla iyileştirme sağladığı saptanıştır. Oluşturulan desenler arasında ise iz boyutu büyük, izler arası mesafesi geniş olan paternin optimum özellikleri sağlayan yüzey olduğu gözlenmiştir. Yüzey pürüzlülüğü ve sıvı içi oksit ve kalsiyum-fosfatlı yapıların çökelmesi arasında bir doğru orantı tespit edilememiş, bu da yüzey enerjisini belirlemede mikrodeformasyonun mikroyapısal mekanizmalar üzerindeki etkisinin daha belirleyici olabileceğine dair ön bulgular ortaya koymuştur
    corecore