329 research outputs found

    A Lipid Bilayer Formed on a Hydrogel Bead for Single Ion Channel Recordings

    Get PDF
    Ion channel proteins play important roles in various cell functions, making them attractive drug targets. Artificial lipid bilayer recording is a technique used to measure the ion transport activities of channel proteins with high sensitivity and accuracy. However, the measurement efficiency is low. In order to improve the efficiency, we developed a method that allows us to form bilayers on a hydrogel bead and record channel currents promptly. We tested our system by measuring the activities of various types of channels, including gramicidin, alamethicin, alpha-hemolysin, a voltage-dependent anion channel 1 (VDAC1), a voltage- and calcium-activated large conductance potassium channel (BK channel), and a potassium channel from Streptomyces lividans (KcsA channel). We confirmed the ability for enhanced measurement efficiency and measurement system miniaturizion

    New records of Ummidia fragaria (Araneae: Ctenizidae) from Tottori Prefecture, Honshu, Japan.

    Get PDF
    Four localities (three in Tottori City, one in Hinocho) of an endangered spider Ummidia fragaria (Araneae, Ctenizidae) are newly recorded from Tottori Prefecture, Japan. All the localities are in the precincts of shrines

    Numerical Simulation of the Solid Particle Sedimentation and Bed Formation Behaviors Using a Hybrid Method

    Get PDF
    In the safety analysis of sodium-cooled fast reactors, numerical simulations of various thermal-hydraulic phenomena with multicomponent and multiphase flows in core disruptive accidents (CDAs) are regarded as particularly difficult. In the material relocation phase of CDAs, core debris settle down on a core support structure and/or an in-vessel retention device and form a debris bed. The bed’s shape is crucial for the subsequent relocation of the molten core and heat removal capability as well as re-criticality. In this study, a hybrid numerical simulation method, coupling the multi-fluid model of the three-dimensional fast reactor safety analysis code SIMMER-IV with the discrete element method (DEM), was applied to analyze the sedimentation and bed formation behaviors of core debris. Three-dimensional simulations were performed and compared with results obtained in a series of particle sedimentation experiments. The present simulation predicts the sedimentation behavior of mixed particles with different properties as well as homogeneous particles. The simulation results on bed shapes and particle distribution in the bed agree well with experimental measurements. They demonstrate the practicality of the present hybrid method to solid particle sedimentation and bed formation behaviors of mixed as well as homogeneous particles

    Estimation of diameter growth parameters for Cryptomeria Plantations in� Taiwan Using the Local Yield Table Construction System

    Get PDF
    We applied the Local Yield Table Construction System (LYCS), a computer program that estimates stand growth as a function of various density control strategies, to Cryptomeria plantations in Taiwan. Parameters of the growth model were estimated from permanent plot data on Cryptomeria stands stored in a database at the Experimental Forest of National Taiwan University. The diameter at breast height (DBH) and the number of trees measured in permanent plots were used as parameters to estimate the curve of the DBH growth rate, the effects of stand density on diameter growth, growth in terms of DBH, and diameter distribution. The estimated stand growth could be adapted to the observed values in the permanent plots. Based on these results, yield tables for various stand density control strategies can now be constructed for Cryptomeria stands in Taiwan

    A 1.5-Mb PAC/BAC Contig Spanning the Prader-Willi Syndrome Critical Region (PWCR)

    Get PDF
    Prader-Willi syndrome (PWS) is a multiple anomalies/mental retardation syndrome. The putative PWS gene(s) remains unknown, and its occurrence is based on genomic imprinting at chromosome 15q11-q13. We have constructed a 1.5- Mb, fine, physical map of PWS critical region (PWCR) between two markers, D15S9 and D15S174 at 15q11-q13. The map is composed of 32 PAC and 3 BAC clones without any gaps. By the PAC/BAC-end sequencing procedure, a total of 26 sequence tag site (STS) markers were newly generated, and 5 expressed sequence tags (ESTs) were mapped in the region. The contig map was verified by both STS and fluorescence in situ hybridization analyses. Our map has higher resolution, compared with a previous YAC-based map of PWCR. It is useful for further genome analysis, especially on genomic imprinting of this region

    Association of coronary revascularisation after physician-referred non-invasive diagnostic imaging tests with outcomes in patients with suspected coronary artery disease: a post hoc subgroup analysis

    Get PDF
    Objective: We aimed to evaluate the association of the prognostic impact of coronary revascularisation with physician-referred non-invasive diagnostic imaging tests (single photon emission CT (SPECT) vs coronary CT angiography) for coronary artery disease. Design: A post hoc analysis of a subgroup from the patient cohort recruited for the Japanese Coronary-Angiography or Myocardial Imaging for Angina Pectoris Study. Setting: Multiple centres in Japan. Participants: From the data of 2780 patients with stable angina, enrolled prospectively between January 2006 and March 2008 in Japan, who had undergone physician-referred non-invasive imaging tests, 1205 patients with SPECT as an initial strategy and 625 with CT as an initial strategy were analysed. We assessed the effect of revascularisation (within 90 days) in each diagnostic imaging stratum and the interaction between the two strata. Primary and secondary outcome measures: Major adverse cardiac events (MACEs), including death, myocardial infarction, hospitalisation for heart failure and late revascularisation, were followed up for 1 year. The χ2 test, Student’s t-test, Kaplan-Meier analysis, log-rank test and multivariable Cox proportional hazard model were used in data analysis. Results: A total of 210 (17.4%) patients in the SPECT stratum and 149 (23.8%) in the CT stratum underwent revascularisation. Although in each stratum, the cumulative 1 year incidence of MACEs was significantly higher in patients who underwent revascularisation than in those who did not (SPECT stratum: 9.1 vs 1.2%, log-rank p<0.0001; CT stratum: 6.1 vs 0.8%, log-rank p=0.0001), there was no interaction between the risk of revascularisation and the imaging strata (SPECT stratum: adjusted HR (95% CI), 4.25 (1.86–9.72); CT stratum: 4.13 (1.16–14.73); interaction: p=0.97). Conclusion: The association of revascularisation with the outcomes of patients with suspected coronary artery disease was not different between SPECT-first and CT-first strategies in a physician-referred fashion
    corecore