668 research outputs found

    On The Implementation Of Experimental Solenoids In MAD-X And Their Effect On Coupling In The LHC

    Get PDF
    The betatron coupling introduced by the experimental solenoids in the LHC is small at injection and negligible at collision energy. We present a study of these effects and look at possible corrections. Additionally we report about the implementation of solenoids in the MAD-X program. A thin solenoid version is also made available for tracking purposes

    Treatment of streptococcal endocarditis with a single daily dose of ceftriaxone sodium for 4 weeks. Efficacy and outpatient treatment feasibility

    Get PDF
    OBJECTIVE--To evaluate the efficacy and safety of ceftriaxone sodium in the treatment of streptococcal endocarditis. DESIGN--An open, multicenter, noncomparative study with a follow-up of patients for 4 months to 5 years. SETTING--Internal medicine wards and outpatient clinics of hospitals of various sizes in three European countries. PATIENTS--Fifty-nine patients with defined criteria for streptococcal endocarditis. INTERVENTION--Ceftriaxone sodium administered at a once-daily dose of 2 g for 4 weeks. MAIN OUTCOME MEASURES--Clinical outcome and microbiological cure rate. RESULTS--Among the 59 patients, 55 completed the treatment and were followed up for 4 months to 5 years. No patients showed evidence of relapse. Treatment was completely uneventful in 42 patients (71%). A cardiac valve was replaced in four patients (7%) receiving antimicrobial therapy and in six patients (10%) who had completed antimicrobial therapy. One of the 10 valves taken for culture at surgery was positive, but only for microorganisms that were different from the microorganism isolated before the treatment. The treatment had to be interrupted in four patients because of drug allergy. Other side effects were mild except for two cases of reversible neutropenia. The treatment was easy to administer: 27 patients (46%) had no permanent intravenous catheter at any time, seven patients (12%) had such a catheter for less than 4 days. Twenty-three patients (39%) were discharged from the hospital less than 2 weeks after admission. CONCLUSIONS.--Ceftriaxone sodium administered at a once-daily dose of 2 g appears to be an effective and safe treatment of streptococcal endocarditis. In hospitals, this agent may be more convenient to administer than penicillin G with or without aminoglycosides. Some patients may even be treated as outpatients

    Beam Dynamics for the CTF3 Preliminary Phase

    Get PDF
    In the framework of the CLIC RF power source studies, the new scheme of electron pulse compression and bunch frequency multiplication, using injection by RF deflectors into an isochronous ring, will be tested at CERN during the CTF3 preliminary phase. The present LPI complex will be modified in order to allow a test of this scheme at low charge. The design of the new front-end, of the modified linac, of the matched transfer line, and of the isochronous ring lattice is presented here.The results of the related beam dynamics studies are also discussed

    Beam Dynamics for the Preliminary Phase of the New CLIC Test Facility (CTF3)

    Get PDF
    In the framework of the CLIC (Compact Linear Collider) RF power source studies, the scheme of electron pulse compression and bunch frequency mulitiplication, using injection by RF deflectors into an isochronous ring, will be tested, at low charge, during the preliminary phase of the new CLIC Test Facility (CTF3) at CERN. In this paper, we describe the beam dynamics studies made in order to assess the feasibility of the bunch combination experiment, as well as the related beam measurements performed on the LEP Pre-Injector complex (LPI) before its transformation into CTF

    A more robust and flexible lattice for LHC

    Get PDF
    To correct more efficiently the arc dispersion, the exact antisymmetry of the LHC optics is now broken, except in the low-b triplets common to the two rings. A new quadrupole is added between the experimental insertions and the dispersion suppressors and several arc quadrupoles are complemented by a small trim quadrupole. The larger number of parameters gives flexibility to the lattice and allows a partial separation of the optical functions, with a decrease of the total number of quadrupole units. It is possible to change rather freely the phase advances of the arc cells. The nominal tunes are split by 4 units to reduce coupling. The bin boot tuning range in the experimental low-b is significantly increased, allowing e.g. a larger beam separation at injection. The super-periodicity of LHC remains 1. We plan to study whether it can be increased within the LHC hardware constraint

    Optics Flexibility and Dispersion Matching at Injection into the LHC

    Get PDF
    The LHC requires very precise matching of transfer line and LHC optics to minimise emittance blow-up and tail repopulation at injection. The recent addition of a comprehensive transfer line collimation system to improve the protection against beam loss has created additional matching constraints and consumed a significant part of the flexibility contained in the initial optics design of the transfer lines. Optical errors, different injection configurations and possible future optics changes require however to preserve a certain tuning range. Here we present methods of tuning optics parameters at the injection point by using orbit correctors in the main ring, with the emphasis on dispersion matching. The benefit of alternative measures to enhance the flexibility is briefly discussed

    Satellite Tracking and Site Fidelity of Short Ocean Sunfish, Mola ramsayi, in the Galapagos Islands

    Get PDF
    Ocean sunfishes, with their peculiar morphology, large size, and surface habits, are valuable assets in ecotourism destinations worldwide. This study investigates site fidelity and long-range movements of short ocean sunfish, Mola ramsayi (Giglioli 1883), at Punta Vicente Roca (PVR) off Isabela Island in the Galapagos Islands. Five individuals were tracked between 32 and 733 days using ultrasonic receivers and transmitters. Two of the 5 were also tracked with towed pop-off satellite tags. One travelled to the equatorial front covering 2700 km in 53 days, with dive depths in the upper 360 m at temperatures between 9.2°C and 22°C. During its westward travel, dives extended to 1112 m (the deepest depth yet recorded for Molidae) into temperatures ranging between 4.5°C and 23.2°C. The remaining four individuals demonstrated site fidelity to PVR and were detected at the site between 128–1361 times for a total of 3557 reports. Forty-eight percent of the reports occurred during daytime hours and 52% after dark. Presumed cleaning session durations had a median of 15 minutes and a maximum of nearly 100 minutes. No other ultrasonic arrays around Galapagos or in the Eastern Pacific regional network recorded the presence of tagged individuals. These data are combined with tourist vessel sightings and submersible observations to confirm Punta Vicente Roca as an important sunfish hotspot

    Putting health status guided COPD management to the test:protocol of the MARCH study

    Get PDF
    BACKGROUND: Chronic Obstructive Pulmonary Disease (COPD) is a disease state characterized by airflow limitation that is not fully reversible and usually progressive. Current guidelines, among which the Dutch, have so far based their management strategy mainly on lung function impairment as measured by FEV(1), while it is well known that FEV(1) has a poor correlation with almost all features of COPD that matter to patients. Based on this discrepancy the GOLD 2011 update included symptoms and impact in their treatment algorithm proposal. Health status measures capture both symptoms and impact and could therefore be used as a standardized way to capture the information a doctor could otherwise only collect by careful history taking and recording. We hypothesize that a treatment algorithm that is based on a simple validated 10 item health status questionnaire, the Clinical COPD Questionnaire (CCQ), improves health status (as measured by SGRQ) and classical COPD outcomes like exacerbation frequency, patient satisfaction and health care utilization compared to usual care based on guidelines. METHODS/DESIGN: This hypothesis will be tested in a randomized controlled trial (RCT) following 330 patients for two years. During this period general practitioners will receive treatment advices every four months that are based on the patient’s health status (in half of the patients, intervention group) or on lung function (the remaining half of the patients, usual care group). DISCUSSION: During the design process, the selection of outcomes and the development of the treatment algorithm were challenging. This is discussed in detail in the manuscript to facilitate researchers in designing future studies in this changing field of implementation research. TRIAL REGISTRATION: Netherlands Trial Register, NTR264

    Dynamical aperture studies for the CERN LHC: comparison between statistical assignment of magnetic field errors and actual measured field errors

    Get PDF
    It is customary to evaluate the performance of a circular particle accelerator by computing the dynamical aperture, i.e. the domain in phase space where bounded singleparticle motion occurs. In the case of the LHC the dynamical aperture computation is performed by assuming a statistical distribution of the magnetic field errors of various magnets classes: the numerical computations are repeated for a given set of realisations of the LHC ring. With the progress in the magnet production and allocation of the available positions in the ring, the statistical approach has to be replaced by the computation of one single configuration, namely the actual realisation of the machine. Comparisons between the two approaches are presented and discussed in details.Â

    CLIC simulations from the start of the linac to the interaction point

    Get PDF
    Simulations for linear colliders are traditionally performed separately for the different sub-systems, like damping ring, bunch compressor, linac, and beam delivery. The beam properties are usually passed from one sub-system to the other via bunch charge, RMS transverse emittances, RMS bunch length, average energy and RMS energy spread. It is implicitly assumed that the detailed 6D correlations in the beam distribution are not relevant for the achievable luminosity. However, it has recently been shown that those correlations can have a strong effect on the beam-beam interaction. We present first results on CLIC simulations that integrate linac, beam delivery, and beam-beam interaction. These integrated simulations also allow a better simulation of time-dependent effects, like ground perturbations and interference between several beam-based feedbacks
    corecore