221 research outputs found

    SP-0627: Tumour hypoxia imaging to individualise radiotherapy

    Get PDF

    Detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT)

    Get PDF
    The purpose of this study was to analyze the detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG-PET/CT). Data for a total of 492 patients who had undergone both PET/CT and colonoscopy were analyzed. After the findings of PET/CT and colonoscopy were determined independently, the results were compared in each of the six colonic sites examined in all patients. The efficacy of PET/CT was determined using colonoscopic examination as the gold standard. In all, 270 colorectal lesions 5 mm or more in size, including 70 pathologically confirmed malignant lesions, were found in 172 patients by colonoscopy. The sensitivity and specificity of PET/CT for detecting any of the colorectal lesions were 36 and 98%, respectively. For detecting lesions 11 mm or larger, the sensitivity was increased to 85%, with the specificity remaining consistent (97%). Moreover, the sensitivity for tumors 21 mm or larger was 96% (48/50). Tumors with malignant or high-grade pathology were likely to be positive with PET/CT. A size of 10 mm or smaller [odds ratio (OR) 44.14, 95% confidence interval (95% CI) 11.44-221.67] and flat morphology (OR 7.78, 95% CI 1.79-36.25) were significant factors that were associated with false-negative cases on PET/CT. The sensitivity of PET/CT for detecting colorectal lesions is acceptable, showing size- and pathology-dependence, suggesting, for the most part, that clinically relevant lesions are detectable with PET/CT. However, when considering PET/CT for screening purposes caution must be exercised because there are cases of false-negative results

    Dose escalation to high-risk sub-volumes based on non-invasive imaging of hypoxia and glycolytic activity in canine solid tumors:a feasibility study

    Get PDF
    INTRODUCTION: Glycolytic activity and hypoxia are associated with poor prognosis and radiation resistance. Including both the tumor uptake of 2-deoxy-2-[(18) F]-fluorodeoxyglucose (FDG) and the proposed hypoxia tracer copper(II)diacetyl-bis(N(4))-methylsemithio-carbazone (Cu-ATSM) in targeted therapy planning may therefore lead to improved tumor control. In this study we analyzed the overlap between sub-volumes of FDG and hypoxia assessed by the uptake of (64)Cu-ATSM in canine solid tumors, and evaluated the possibilities for dose redistribution within the gross tumor volume (GTV). MATERIALS AND METHODS: Positron emission tomography/computed tomography (PET/CT) scans of five spontaneous canine solid tumors were included. FDG-PET/CT was obtained at day 1, (64)Cu-ATSM at day 2 and 3 (3 and 24 h pi.). GTV was delineated and CT images were co-registered. Sub-volumes for 3 h and 24 h (64)Cu-ATSM (Cu3 and Cu24) were defined by a threshold based method. FDG sub-volumes were delineated at 40% (FDG40) and 50% (FDG50) of SUV(max). The size of sub-volumes, intersection and biological target volume (BTV) were measured in a treatment planning software. By varying the average dose prescription to the tumor from 66 to 85 Gy, the possible dose boost (D( B )) was calculated for the three scenarios that the optimal target for the boost was one, the union or the intersection of the FDG and (64)Cu-ATSM sub-volumes. RESULTS: The potential boost volumes represented a fairly large fraction of the total GTV: Cu3 49.8% (26.8-72.5%), Cu24 28.1% (2.4-54.3%), FDG40 45.2% (10.1-75.2%), and FDG50 32.5% (2.6-68.1%). A BTV including the union (∪) of Cu3 and FDG would involve boosting to a larger fraction of the GTV, in the case of Cu3∪FDG40 63.5% (51.8-83.8) and Cu3∪FDG50 48.1% (43.7-80.8). The union allowed only a very limited D( B ) whereas the intersection allowed a substantial dose escalation. CONCLUSIONS: FDG and (64)Cu-ATSM sub-volumes were only partly overlapping, suggesting that the tracers offer complementing information on tumor physiology. Targeting the combined PET positive volume (BTV) for dose escalation within the GTV results in a limited D( B ). This suggests a more refined dose redistribution based on a weighted combination of the PET tracers in order to obtain an improved tumor control

    The role of alexithymia and empathy on radiation therapists’ professional quality of life

    Get PDF
    Background and purpose: Physical and mental well-being are crucial for oncology professionals as they affect performance at work. Personality traits, as alexithymia and empathy, may influence professional quality of life. Alexithymia involves diminished skills in emotion processing and awareness. Empathy is pertinent to the ability to understand another's ‘state of mind/emotion’. The PROject on Burn-Out in RadiatioN Oncology (PRO BONO) investigates professional quality of life amongst radiation oncology professionals, exploring the role of alexithymia and empathy. The present study reports on data pertinent to radiation therapists (RTTs). Material and methods: An online survey targeted ESTRO members. Participants were asked to fill out 3 questionnaires for alexithymia, empathy and professional quality of life: (a) Toronto Alexithymia Scale (TAS-20); (b) Interpersonal Reactivity Index (IRI); (c) Professional Quality of Life Scale (ProQoL). The present analysis focuses on RTTS to evaluate compassion satisfaction (CS), secondary traumatic stress (STS) and Burnout and their correlation with alexithymia and empathy, using generalized linear modeling. Covariates found significant at univariate linear regression analysis were included in the multivariate linear regression model. Results: A total of 399 RTTs completed all questionnaires. The final model for the burnout scale of ProQoL found, as significal predictors, the TAS-20 total score (β = 0.46, p < 0 0.001), and the individual's perception of being valued by supervisor (β = −0.29, p < 0.001). With respect to CS, the final model included TAS-20 total score (β = −0.33, p < 0.001), the Empatic Concern domain (β = 0.23, p < 0.001) of the IRI questionnaire and the individual's perception of being valued by colleagues (β = 0.22, p < 0.001). Conclusions: Alexithymia increased the likelyhood to experience burnout and negatively affected the professional quality of life amongst RTTs working in oncology. Empathy resulted in higher professional fulfillment together with collegaues’ appreciation. These results may be used to benchmark preventing strategies and implement organization-direct and/or individual-directed interventions

    Germline mutations including the rare pathogenic variant c.3206delC in the ATM gene cause ataxia teleangiectasia-associated primary central nervous system lymphoma

    Get PDF
    We here report the case of a 2-year-old patient with a primary central nervous system lymphoma of B-cell origin. Due to their past medical history of repeated respiratory tract infections and the marked chemotherapy-associated toxicity and infectious comorbidity, we suspected that the patient also suffered from an inherited immune deficiency disorder. Despite the lack of classical pathognomonic symptoms for ataxia teleangiectasia and missing evidence for a cancer predisposition syndrome in the family, genetic testing identified biallelic germline mutations, including the rare pathogenic variant c.3206delC (p.Pro1069Leufs*2), in the ataxia telangiectasia-mutated (ATM) gene. The case highlights the importance of searching for immune deficiency disorders associated with primary central nervous system lymphoma before treatment initiation and the urgent need to develop novel treatment strategies for cancer patients with underlying immunodeficiency syndromes

    A multi-institutional comparison of retrospective deformable dose accumulation for online adaptive magnetic resonance-guided radiotherapy

    Get PDF
    Background and Purpose: Application of different deformable dose accumulation (DDA) solutions makes institutional comparisons after online-adaptive magnetic resonance-guided radiotherapy (OA-MRgRT) challenging. The aim of this multi-institutional study was to analyze accuracy and agreement of DDA-implementations in OA-MRgRT. Material and Methods: One gold standard (GS) case deformed with a biomechanical-model and five clinical cases consisting of prostate (2x), cervix, liver, and lymph node cancer, treated with OA-MRgRT, were analyzed. Six centers conducted DDA using institutional implementations. Deformable image registration (DIR) and DDA results were compared using the contour metrics Dice Similarity Coefficient (DSC), surface-DSC, Hausdorff-distance (HD95%), and accumulated dose-volume histograms (DVHs) analyzed via intraclass correlation coefficient (ICC) and clinical dosimetric criteria (CDC). Results: For the GS, median DDA errors ranged from 0.0 to 2.8 Gy across contours and implementations. DIR of clinical cases resulted in DSC > 0.8 for up to 81.3% of contours and a variability of surface-DSC values depending on the implementation. Maximum HD95%=73.3 mm was found for duodenum in the liver case. Although DVH ICC > 0.90 was found after DDA for all but two contours, relevant absolute CDC differences were observed in clinical cases: Prostate I/II showed maximum differences in bladder V28Gy (10.2/7.6%), while for cervix, liver, and lymph node the highest differences were found for rectum D2cm3 (2.8 Gy), duodenum Dmax (7.1 Gy), and rectum D0.5cm3 (4.6 Gy). Conclusion: Overall, high agreement was found between the different DIR and DDA implementations. Case- and algorithm-dependent differences were observed, leading to potentially clinically relevant results. Larger studies are needed to define future DDA-guidelines
    • …
    corecore