    Comparison of Current Balancing Configurations for Primary Parallel Isolated Boost Converter

    Get PDF
    Different current balancing configurations have been investigated for Primary Parallel Isolated Boost Converter (PPIBC). It has been shown that parallel branch current balancing is possible with several configurations of coupled/uncoupled inductors. Analytical expressions for branch currents have been derived for different cases of gate signal mismatch causing current imbalance. It has been observed that turn-on and turn-off delays in parallel power stages of the PPIBC have different effects in the branch currents deviating from ideal. It has also been observed that in some configurations inductance differences due to core tolerances play an important role in current imbalance. Analytical and simulation results have shown that another side effect of the gate signal delay and inductor value difference is additional voltage stress over the switches during the mismatch times. Advantages of each configuration in terms of effective current balancing, efficiency and manufacturing simplicity have been highlighted. Simulations with ideal components for each case have been carried out to confirm the analytical derivations. Experimental results have also been included to show the performances of different configurations where component non-idealities like transformer leakage inductances also become effective

    ‘All in a box’ a concept for optimizing microbiological diagnostic sampling in prosthetic joint infections

    Get PDF
    BACKGROUND: Accurate microbial diagnosis is crucial for effective management of prosthetic joint infections. Culturing of multiple intraoperative tissue samples has increased diagnostic accuracy, but new preparatory techniques and molecular methods hold promise of further improvement. The increased complexity of sampling is, however, a tough challenge for surgeons and assistants in the operation theatre, and therefore we devised and tested a new concept of pre-packed boxes with a complete assortment of swabs, vials and additional tools needed in the operating theatre for non-standard samples during a clinical study of prosthetic joint infections. FINDINGS: The protocol for the clinical study required triplicate samples of joint fluid, periprosthetic tissue, bone tissue, and swabs from the surface of the prosthesis. Separate boxes were prepared for percutaneous joint puncture and surgical revision; the latter included containers for prosthetic components or the entire prosthesis. During a 2-year project period 164 boxes were used by the surgeons, 98 of which contained a complete set of samples. In all, 1508 (89%) of 1685 scheduled samples were received. CONCLUSION: With this concept a high level of completeness of sample sets was achieved and thus secured a valid basis for evaluation of new diagnostics. Although enthusiasm for the project may have been a contributing factor, the extended project period suggests that the ‘All in a box’ concept is equally applicable in routine clinical settings with standardized but complex diagnostic sampling

    Estimation of contact resistivity in lightning protection equipotential Bonding joints of wind turbine blades

    Get PDF
    Modern lightning protection systems for wind turbine blades with conducting structural elements, e.g., carbon fiber reinforced polymer (CFRP) spar caps, contain equipotential bonding joints to prevent sparking during strikes. Significant current levels are experienced through the joints and the characterization of the electrical contact at the bonding regions is essential for reliable protection. Therefore, this article aims to characterize the contact resistivity of several equipotential bonding joints. The proposed methodology first measures the total resistance of the samples, and then the bulk resistance of the conductive elements is computed using the finite-element method. The latter is required to predict the spreading effects in CFRP components due to the strong anisotropic nature of such materials. After that, the contact resistance is calculated by subtracting the predicted bulk resistances from the measured total resistances. The developed procedure was applied to three typical equipotential bonding materials: expanded copper foil (ECF), biaxial (BIAX) CFRP, and unidirectional (UD) CFRP. Both ECF and BIAX CFRP showed superior contact quality than the UD CFRP, with one to two orders of magnitude smaller contact resistivity.</p

    Comparison of current balancing configurations for Primary Parallel Isolated Boost Converter

    Get PDF
    Let G be a permutation group acting on a set . A subset of is a base for G ifits pointwise stabilizer in G is trivial. We write b(G) for the minimal size of a base forG. We determine the precise value of b(G) for every primitive almost simple sporadicgroup G, with the exception of two cases involving the Baby Monster group. As acorollary, we deduce that b(G) 6 7, with equality if and only if G is the Mathieu groupM24 in its natural action on 24 points. This settles a conjecture of Cameron

    Addressing Inequity to Achieve the Maternal and Child Health Millennium Development Goals: Looking Beyond Averages.

    Get PDF
    Inequity in access to and use of child and maternal health interventions is impeding progress towards the maternal and child health Millennium Development Goals. This study explores the potential health gains and equity impact if a set of priority interventions for mothers and under fives were scaled up to reach national universal coverage targets for MDGs in Tanzania. We used the Lives Saved Tool (LiST) to estimate potential reductions in maternal and child mortality and the number of lives saved across wealth quintiles and between rural and urban settings. High impact maternal and child health interventions were modelled for a five-year scale up, by linking intervention coverage, effectiveness and cause of mortality using data from Tanzania. Concentration curves were drawn and the concentration index estimated to measure the equity impact of the scale up. In the poorest population quintiles in Tanzania, the lives of more than twice as many mothers and under-fives were likely to be saved, compared to the richest quintile. Scaling up coverage to equal levels across quintiles would reduce inequality in maternal and child mortality from a pro rich concentration index of -0.11 (maternal) and -0.12 (children) to a more equitable concentration index of -0,03 and -0.03 respectively. In rural areas, there would likely be an eight times greater reduction in maternal deaths than in urban areas and a five times greater reduction in child deaths than in urban areas. Scaling up priority maternal and child health interventions to equal levels would potentially save far more lives in the poorest populations, and would accelerate equitable progress towards maternal and child health MDGs

    Differential contributions of specimen types, culturing, and 16S rRNA sequencing in diagnosis of prosthetic joint infections

    Get PDF
    ABSTRACT Prosthetic joint failure is mainly caused by infection, aseptic failure (AF), and mechanical problems. Infection detection has been improved with modified culture methods and molecular diagnostics. However, comparisons between modified and conventional microbiology methods are difficult due to variations in specimen sampling. In this prospective, multidisciplinary study of hip or knee prosthetic failures, we assessed the contributions of different specimen types, extended culture incubations, and 16S rRNA sequencing for diagnosing prosthetic joint infections (PJI). Project specimens included joint fluid (JF), bone biopsy specimens (BB), soft-tissue biopsy specimens (STB), and swabs (SW) from the prosthesis, collected in situ , and sonication fluid collected from prosthetic components (PC). Specimens were cultured for 6 (conventional) or 14 days, and 16S rRNA sequencing was performed at study completion. Of the 156 patients enrolled, 111 underwent 114 surgical revisions (cases) due to indications of either PJI ( n = 43) or AF ( n = 71). Conventional tissue biopsy cultures confirmed PJI in 28/43 (65%) cases and refuted AF in 3/71 (4%) cases; one case was not evaluable. Based on these results, minor diagnostic adjustments were made. Fourteen-day cultures of JF, STB, and PC specimens confirmed PJI in 39/42 (93%) cases, and 16S rRNA sequencing confirmed PJI in 33/42 (83%) cases. One PJI case was confirmed with 16S rRNA sequencing alone and five with cultures of project specimens alone. These findings indicated that JF, STB, and PC specimen cultures qualified as an optimal diagnostic set. The contribution of sequencing to diagnosis of PJI may depend on patient selection; this hypothesis requires further investigation. </jats:p
    corecore