41 research outputs found

    Optical Study of a Spectrum Splitting Solar Concentrator based on a Combination of a Diffraction Grating and a Fresnel Lens

    Full text link
    This poster presents recent improvements of our new solar concentrator design for space application. The concentrator is based on a combination of a diffraction grating (blazed or lamellar) coupled with a Fresnel lens. Thanks to this diffractive/refractive combination, this optical element splits spatially and spectrally the light and focus approximately respectively visible light and IR light onto electrically independent specific cells. It avoid the use of MJs cells and then also their limitations like current matching and lattice matching conditions, leading theoretically to a more tolerant system. The concept is reminded, with recent optimizations, ideal and more realistic results, and the description of an experimental realization highlighting the feasibility of the concept, and the closeness of theoretical and experimental results

    Space radiation parameters for EUI and the Sun Sensor of Solar Orbiter, ESIO and JUDE instruments

    Full text link
    This paper presents predictions of space radiation parameters for four space instruments performed by the Centre Spatial de Liège (ULg – Belgium); EUI, the Extreme Ultra-violet Instrument, on-board the Solar Orbiter platform; ESIO, Extreme-UV solar Imager for Operations, and JUDE, the Jupiter system Ultraviolet Dynamics Experiment, which was proposed for the JUICE platform. For Solar Orbiter platform, the radiation environment is defined by ESA environmental specification and the determination of the parameters is done through ray-trace analyses inside the EUI instrument. For ESIO instrument, the radiation environment of the geostationary orbit is defined through simulations of the trapped particles flux, the energetic solar protons flux and the galactic cosmic rays flux, taking the ECSS standard for space environment as a guideline. Then ray-trace analyses inside the instrument are performed to predict the particles fluxes at the level of the most radiation-sensitive elements of the instrument. For JUICE, the spacecraft trajectory is built from ephemeris files provided by ESA and the radiation environment is modeled through simulations by JOSE (Jovian Specification Environment model) then ray-trace analyses inside the instrument are performed to predict the particles fluxes at the level of the most radiation-sensitive elements of the instrument

    Continuous Solar Simulator for Concentrator Photovoltaic Systems

    Full text link
    A continuous solar simulator for measuring performance of concentrator photovoltaic (CPV) systems is presented. The illumination system is based on a Xenon lamp, a homogenizer rod, shaping optics and a 30cm diameter collimator. The design optimises the reproduction of the characteristics of direct solar illumination: 32’ divergence, high spatial homogeneity, sun-like spectral distribution, with a maximum intensity of 250W/m². It accommodates pass-band and attenuation filters to tune the beam output. It operates in continuous mode, allowing to investigate CPV thermal aspects as well. The present paper addresses the concept design of the solar simulator and associated performance results

    The Athena X-ray Integral Field Unit (X-IFU)

    Get PDF
    The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on similar to 5 '' pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at similar to 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 mu m. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of similar to 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a He-3 sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (> 50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018. The X-IFU will be provided by an international consortium led by France, the Netherlands and Italy, with further ESA member state contributions from Belgium, Czech Republic, Finland, Germany, Ireland, Poland, Spain, Switzerland and contributions from Japan and the United States.Peer reviewe

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Full text link
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).Comment: 48 pages, 29 figures, Accepted for publication in Experimental Astronomy with minor editin

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory. Athena is a versatile observatory designed to address the Hot and Energetic Universe science theme, as selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), X-IFU aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over a hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR (i.e. in the course of its preliminary definition phase, so-called B1), browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters, such as the instrument efficiency, spectral resolution, energy scale knowledge, count rate capability, non X-ray background and target of opportunity efficiency. Finally, we briefly discuss the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, touch on communication and outreach activities, the consortium organisation and the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with ESA member state contributions from Belgium, Czech Republic, Finland, Germany, Poland, Spain, Switzerland, with additional contributions from the United States and Japan.The French contribution to X-IFU is funded by CNES, CNRS and CEA. This work has been also supported by ASI (Italian Space Agency) through the Contract 2019-27-HH.0, and by the ESA (European Space Agency) Core Technology Program (CTP) Contract No. 4000114932/15/NL/BW and the AREMBES - ESA CTP No.4000116655/16/NL/BW. This publication is part of grant RTI2018-096686-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. This publication is part of grant RTI2018-096686-B-C21 and PID2020-115325GB-C31 funded by MCIN/AEI/10.13039/501100011033

    Optical and radiometric models of the NOMAD instrument part II: The infrared channels - SO and LNO

    Get PDF

    The Athena X-ray observatory and the Liège contribution to the X-IFU instrument

    Full text link
    Athena is ESA's next generation X-ray observatory that will address many science questions related to the hot and energetic Universe, but will also perform unprecedented observations of all kinds of objects in the Universe. Athena will notably carry the X-ray Integral Field Unit (X-IFU), an X-ray calorimeter that will perform high-resolution X-ray spectroscopy of extended sources. STAR (CSL + GAPHE teams) contributes to the design of X-IFU. In this presentation, we will briefly highlight the anticipated science capabilities of Athena as well as the Liège contribution to the X-IFU consortium

    Optical Study of a Spectrum Splitting Solar Concentrator based on a Combination of a Diffraction Grating and a Fresnel Lens

    Full text link
    This paper presents recent improvements of our new solar concentrator design for space application. The concentrator is based on a combination of a diffraction grating (blazed or lamellar) coupled with a Fresnel lens. Thanks to this diffractive/refractive combination, this optical element splits spatially and spectrally the light and focus approximately respectively visible light and IR light onto electrically independent specific cells. It avoid the use of MJs cells and then also their limitations like current matching and lattice matching conditions, leading theoretically to a more tolerant system. The concept is reminded, with recent optimizations, ideal and more realistic results, and the description of an experimental realization highlighting the feasibility of the concept and the closeness of theoretical and experimental results

    Study of a solar concentrator for space based on a diffractive/refractive optical combination

    Full text link
    The present work proposes a theoretical optical study of a new planar solar concentrator for space applications. The concentrator focuses light onto three spatially separated photovoltaic cells (three single-junctions, dedicated to two different light spectra), allowing for independent control of the output power of each cell. The design, based on a blazed diffraction grating superimposed on a Fresnel lens, combines advantages of both spectral splitting and light focusing. Theoretical model and optimization of the optical design are presented, including the variation of the grating period along the lens. Numerical results are detailed, highlighting the possibility to design a concentrator at more than 10× for each cell, with an optical efficiency of ~71% and less than 10% of losses for tracking errors < ±0.85°. A thermal study completes the work, as well as a first theoretical comparison with a planar Fresnel based solar concentrator focusing on a GaAs cell
    corecore