8 research outputs found

    First experience with the wearable cardioverter defibrillator in the Netherlands

    Get PDF
    The implantable cardioverter defibrillator (ICD) has significantly improved survival in patients with an increased risk of sudden cardiac death (SCD). The wearable cardioverter defibrillator (WCD) is an alternative to the ICD in patients with a transient ICD indication or those in whom an ICD temporarily cannot be implanted. We describe here the technical details of the WCD and report three patients who were treated with a WCD in an outpatient setting. The WCD allowed the cardiac condition of two patients to improve to such an extent that permanent ICD implantation was deemed unnecessary. This new form of therapy may result in significant cost reduction, avoidance of unnecessary ICD implantation, and increased patient satisfaction

    Treatment of Cheyne-Stokes Respiration Reduces Arrhythmic Events in Chronic Heart Failure

    No full text
    Bitter T, Gutleben K-J, Noelker G, et al. Treatment of Cheyne-Stokes Respiration Reduces Arrhythmic Events in Chronic Heart Failure. Journal Of Cardiovascular Electrophysiology. 2013;24(10):1132-1140.Cheyne-Stokes Respiration and Arrhythmias ObjectiveThis study aimed to investigate whether adequate treatment of Cheyne-Stokes respiration (CSR) reduces the risk of arrhythmic events in patients with chronic heart failure (CHF). MethodsA cohort of 403 registry patients with CHF (LVEF45%, NYHA-class2) and implanted cardioverter-defibrillator devices (ICD) was studied. They underwent overnight polygraphy, with 221 having mild or no CSR (apnea-hypopnea index [AHI]15/h). Latter ones were offered therapy with adaptive servoventilation (ASV), which 96 patients accepted and 86 rejected. During follow-up (21 15 months) defibrillator therapies were recorded in addition to clinical and physiologic measures of heart failure severity. ResultsEvent-free survival from (a) appropriate cardioverter-defibrillator therapies and (b) appropriately monitored ventricular arrhythmias was shorter in the untreated CSR group compared to the treated CSR and the no CSR group. Stepwise Cox proportional hazard regression analysis showed untreated CSR (a: hazard ratio [HR] 1.99, 95% confidence interval [CI] 1.46-2.72, P < 0.001; b: HR 2.19, 95%CI 1.42-3.37, P < 0.001), but not treated CSR (a: HR 1.06, 95%CI 0.74-1.50; P = 0.77; b: HR 1.21, 95%CI 0.75-1.93, P = 0.43) was an independent risk factor. The treated CSR group showed improvements in cardiac function and respiratory stability compared to the untreated CSR group. ConclusionThis study demonstrates a decrease of appropriate defibrillator therapies by ASV treated CSR in patients with CHF and ICD. A reduced exposure to hyperventilation, hypoxia, and improvement in indices of CHF severity and neurohumoral disarrangements are potential causative mechanisms
    corecore