6,760 research outputs found

    An Extended CMOS ISFET Model Incorporating the Physical Design Geometry and the Effects on Performance and Offset Variation

    No full text
    This paper presents an extended model for the CMOS-based ion-sensitive field-effect transistor, incorporating design parameters associated with the physical geometry of the device. This can, for the first time, provide a good match between calculated and measured characteristics by taking into account the effects of nonidealities such as threshold voltage variation and sensor noise. The model is evaluated through a number of devices with varying design parameters (chemical sensing area and MOSFET dimensions) fabricated in a commercially available 0.35-µm CMOS technology. Threshold voltage, subthreshold slope, chemical sensitivity, drift, and noise were measured and compared with the simulated results. The first- and second-order effects are analyzed in detail, and it is shown that the sensors' performance was in agreement with the proposed model

    Clockless Continuous-Time Neural Spike Sorting: Method, Implementation and Evaluation

    No full text
    In this paper, we present a new method for neural spike sorting based on Continuous Time (CT) signal processing. A set of CT based features are proposed and extracted from CT sampled pulses, and a complete event-driven spike sorting algorithm that performs classification based on these features is developed. Compared to conventional methods for spike sorting, the hardware implementation of the proposed method does not require any synchronisation clock for logic circuits, and thus its power consumption depend solely on the spike activity. This has been implemented using a variable quantisation step CT analogue to digital converter (ADC) with custom digital logic that is driven by level crossing events. Simulation results using synthetic neural data shows a comparable accuracy compared to template matching (TM) and Principle Components Analysis (PCA) based discrete sampled classification

    PCN8 OUTCOMES AND COSTS OF SURROGATE END-POINTS (SES) AND BIOMARKERS IN PHASE I ONCOLOGY CLINICAL TRIALS

    Get PDF

    Continuous-time acquisition of biosignals using a charge-based ADC topology

    Get PDF
    This paper investigates continuous-time (CT) signal acquisition as an activity-dependent and nonuniform sampling alternative to conventional fixed-rate digitisation. We demonstrate the applicability to biosignal representation by quantifying the achievable bandwidth saving by nonuniform quantisation to commonly recorded biological signal fragments allowing a compression ratio of ≈5 and 26 when applied to electrocardiogram and extracellular action potential signals, respectively. We describe several desirable properties of CT sampling, including bandwidth reduction, elimination/reduction of quantisation error, and describe its impact on aliasing. This is followed by demonstration of a resource-efficient hardware implementation. We propose a novel circuit topology for a charge-based CT analogue-to-digital converter that has been optimized for the acquisition of neural signals. This has been implemented in a commercially available 0.35 μm CMOS technology occupying a compact footprint of 0.12 mm 2 . Silicon verified measurements demonstrate an 8-bit resolution and a 4 kHz bandwidth with static power consumption of 3.75 μW from a 1.5 V supply. The dynamic power dissipation is completely activity-dependent, requiring 1.39 pJ energy per conversion

    A 5s-Time-Constant Temperature-Stable Integrator for a Tuneable PID Controller in LOC Applications

    No full text
    Accepted versio

    A class of invisible inhomogeneous media and the control of electromagnetic waves

    Get PDF
    We propose a general method to arbitrarily manipulate an electromagnetic wave propagating in a two-dimensional medium, without introducing any scattering. This leads to a whole class of isotropic spatially varying permittivity and permeability profiles that are invisible while shaping the field magnitude and/or phase. In addition, we propose a metamaterial structure working in the infrared that demonstrates deep sub-wavelength control of the electric field amplitude and strong reduction of the scattering. This work offers an alternative strategy to achieve invisibility with isotropic materials and paves the way for tailoring the propagation of light at the nanoscal

    Direct manipulation of wave amplitude and phase through inverse design of isotropic media

    Get PDF
    In this article we propose a new design methodology to control both amplitude and phase of electromagnetic waves from cylindrical incidence, which utilizes engineered media that does not resort to transformation optics or its quasi-conformal approximations. This method can lead to two-dimensional isotropic, inhomogeneous material profiles of permittivity and permeability, to which a general class of scattering-free wave solutions arise. Our design is based on the separation of the complex wave solution into amplitude and phase. We give two types of examples to validate our methodology.We are supported by the Engineering and Physical Sciences Research Council (EPSRC) of UK [grant number EP/I034548/1]. L Y benefits from EPSRC Durham Symposium 104, LMS Caring Supplementary Grant [Ref. CC-15/16-09] and Antennas group travel grant [EECSRC2/4a], and wants to thank Patrick Bradley, Flynn Castle and Fang Yanlong for inspiring conversations to improve this manuscript

    Adaptive Power Regulation and Data Delivery for Multi-Module Implants

    Get PDF
    Emerging applications for implantable devices are requiring multi-unit systems with intrabody transmission of power and data through wireline interfaces. This paper proposes a novel method for power delivery within such a configuration that makes use of closed loop dynamic regulation. This is implemented for an implantable application requiring a single master and multiple identical slave devices utilising a parallel-connected 4-wire interface. The power regulation is achieved within the master unit through closed loop monitoring of the current consumption to the wired link. Simultaneous power transfer and full-duplex data communication is achieved by superimposing the power carrier and downlink data over two wires and uplink data over a second pair of wires. Measured results using a fully isolated (AC coupled) 4-wire lead, demonstrate this implementation can transmit up to 120 mW of power at 6 V (at the slave device, after eliminating any losses). The master device has a maximum efficiency of 80 % including a dominant dynamic power loss. A 6 V constant supply at the slave device is recovered 1.5 ms after a step of 22 mA

    A CMOS-based neural implantable optrode for optogenetic stimulation and electrical recording

    No full text
    This paper presents a novel integrated optrode for simultaneous optical stimulation and electrical recording for closed -loop optogenetic neuro-prosthetic applications. The design has been implemented in a commercially available 0.35μm CMOS process. The system includes circuits for controlling the optical stimulations; recording local field potentials (LFPs); and onboard diagnostics. The neural interface has two clusters of stimulation and recording sites. Each stimulation site has a bonding point for connecting a micro light emitting diode (μLED) to deliver light to the targeted area of brain tissue. Each recording site is designed to be post-processed with electrode materials to provide monitoring of neural activity. On-chip diagnostic sensing has been included to provide real-time diagnostics for post-implantation and during normal operation

    A Genome-wide gene-expression analysis and database in transgenic mice during development of amyloid or tau pathology

    Get PDF
    We provide microarray data comparing genome-wide differential expression and pathology throughout life in four lines of "amyloid" transgenic mice (mutant human APP, PSEN1, or APP/PSEN1) and "TAU" transgenic mice (mutant human MAPT gene). Microarray data were validated by qPCR and by comparison to human studies, including genome-wide association study (GWAS) hits. Immune gene expression correlated tightly with plaques whereas synaptic genes correlated negatively with neurofibrillary tangles. Network analysis of immune gene modules revealed six hub genes in hippocampus of amyloid mice, four in common with cortex. The hippocampal network in TAU mice was similar except that Trem2 had hub status only in amyloid mice. The cortical network of TAU mice was entirely different with more hub genes and few in common with the other networks, suggesting reasons for specificity of cortical dysfunction in FTDP17. This Resource opens up many areas for investigation. All data are available and searchable at http://www.mouseac.org
    corecore