589 research outputs found

    Pathogen Risk to Human Health in Potable Water Related to Nonpoint Sources of Contamination: Colorado River Alluvium Case Study, River Segment 1428 Phase II Final Report

    Get PDF
    Public and private wells that use alluvial aquifers as a drinking water source have an increased risk of contamination from pathogens. This reconnaissance study, conducted by the Texas Water Resources Institute (TWRI) and subcontractors, focused on Segment 1428 of the Colorado River as a site of highest contamination risk based on (1) density of OSSFs, (2) groundwater chemistry, and (3) areas Texas Commission on Environmental Quality (TCEQ) Water Supply Division has previously identified as either having fecal coliform positive samples in raw well samples or when 1 micron filtration samples are indicative of “Groundwater under the influence of Surface Water.” Groundwater (and adjacent surface water) sampling was conducted following dam releases from Tom Miller Dam and transmitted through Longhorn Dam. Water chemistry data (pH, specific conductance, dissolved oxygen, temperature) was evaluated to determine the effects of the mixing of surface water and groundwater. A transect of wells at different distances from the river was sampled to determine to what degree distance from the river controls the level of pathogens. Transects were sampled at one location along the river. Water samples were analyzed for bacteria. Polymerase chain reaction (PCR) for Cryptosporidium and for selected viruses was conducted on selected samples (minimum of 3). This final report provides an account of activities conducted under this scope of work as well as work from a companion Clean Water Act (CWA) 604(b) grant project titled “Pathogen Risk to Human Health in Potable Water Related to Nonpoint Sources of Contamination: Colorado River Alluvium Case Study, River Segment 1428.”Funding provided through a Clean Water Act Section 319(h) Nonpoint Source Grant from the Texas State Soil and Water Conservation Board and the U. S. Environmental Protection Agenc

    Early evolution of the extraordinary Nova Del 2013 (V339 Del)

    Full text link
    We determine the temporal evolution of the luminosity L(WD), radius R(WD) and effective temperature Teff of the white dwarf (WD) pseudophotosphere of V339 Del from its discovery to around day 40. Another main objective was studying the ionization structure of the ejecta. These aims were achieved by modelling the optical/near-IR spectral energy distribution (SED) using low-resolution spectroscopy (3500 - 9200 A), UBVRcIc and JHKLM photometry. During the fireball stage (Aug. 14.8 - 19.9, 2013), Teff was in the range of 6000 - 12000 K, R(WD) was expanding non-uniformly in time from around 66 to around 300 (d/3 kpc) R(Sun), and L(WD) was super-Eddington, but not constant. After the fireball stage, a large emission measure of 1.0-2.0E+62 (d/3 kpc)**2 cm**(-3) constrained the lower limit of L(WD) to be well above the super-Eddington value. The evolution of the H-alpha line and mainly the transient emergence of the Raman-scattered O VI 1032 A line suggested a biconical ionization structure of the ejecta with a disk-like H I region persisting around the WD until its total ionization, around day 40. It is evident that the nova was not evolving according to the current theoretical prediction. The unusual non-spherically symmetric ejecta of nova V339 Del and its extreme physical conditions and evolution during and after the fireball stage represent interesting new challenges for the theoretical modelling of the nova phenomenon.Comment: 14 pages, 9 figures, 3 tables, accepted for Astronomy and Astrophysic

    Use of Remote Technology in the Surface Water Environmental Monitoring Program at SRS Reducing Measurements in the Field-13336

    Get PDF
    ABSTRACT There are a wide range of sensor and remote technology applications available for use in environmental monitoring programs. Each application has its own set of limitations and can be challenging when attempting to utilize it under diverse environmental field conditions. The Savannah River Site Environmental Monitoring Program has implemented several remote sensing and surface water flow technologies that have increased the quality of the data while reducing the number of field measurements. Implementation of this technology reduced the field time for personnel that commute across the Savannah River Site (SRS) over a span of 310 square miles. The wireless surface water flow technology allows for immediate notification of changing field conditions or equipment failure thus reducing data-loss or erroneous field data and improving data-quality. This wireless flow technology uses the stage-to-flow methodology coupled with implementation of a robust highly accurate Acoustic Doppler Profiler system for measuring discharge under various field conditions. Savings for implementation of the wireless flow application and Flowlink® technology equates to approximately 1175 hours annually for the radiological liquid effluent and surveillance programs

    Quasi-static characterisation and impact testing of auxetic foam for sports safety applications

    Get PDF
    This study compared low strain rate material properties and impact force attenuation of auxetic foam and the conventional open-cell polyurethane counterpart. This furthers our knowledge with regards to how best to apply these highly conformable and breathable auxetic foams to protective sports equipment. Cubes of auxetic foam measuring 150 x 150 x 150 mm were fabricated using a thermo-mechanical conversion process. Quasi-static compression confirmed the converted foam to be auxetic, prior to being sliced into 20 mm thick cuboid samples for further testing. Density, Poisson’s ratio and the stress-strain curve were all found to be dependent on the position of each cuboid from within the cube. Impact tests with a hemispherical drop hammer were performed for energies up to 6 J, on foams covered with a polypropylene sheet between 1 and 2 mm thick. Auxetic samples reduced peak force by ~10 times in comparison to the conventional foam. This work has shown further potential for auxetic foam to be applied to protective equipment, while identifying that improved fabrication methods are required

    Effectiveness of an Inpatient Movement Disorders Program for Patients with Atypical Parkinsonism

    Get PDF
    This paper investigated the effectiveness of an inpatient movement disorders program for patients with atypical parkinsonism, who typically respond poorly to pharmacologic intervention and are challenging to rehabilitate as outpatients. Ninety-one patients with atypical parkinsonism participated in an inpatient movement disorders program. Patients received physical, occupational, and speech therapy for 3 hours/day, 5 to 7 days/week, and pharmacologic adjustments based on daily observation and data. Differences between admission and discharge scores were analyzed for the functional independence measure (FIM), timed up and go test (TUG), two-minute walk test (TMW), Berg balance scale (BBS) and finger tapping test (FT), and all showed significant improvement on discharge (P > .001). Clinically significant improvements in total FIM score were evident in 74% of the patients. Results were similar for ten patients whose medications were not adjusted. Patients with atypical parkinsonism benefit from an inpatient interdisciplinary movement disorders program to improve functional status

    Single view silhouette fitting techniques for estimating tennis racket position

    Get PDF
    Stereo camera systems have been used to track markers attached to a racket, allowing its position to be obtained in three-dimensional (3D) space. Typically, markers are manually selected on the image plane, but this can be time-consuming. A markerless system based on one stationary camera estimating 3D racket position data is desirable for research and play. The markerless method presented in this paper relies on a set of racket silhouette views in a common reference frame captured with a calibrated camera and a silhouette of a racket captured with a camera whose relative pose is outside the common reference frame. The aim of this paper is to provide validation of these single view fitting techniques to estimate the pose of a tennis racket. This includes the development of a calibration method to provide the relative pose of a stationary camera with respect to a racket. Mean static racket position was reconstructed to within ±2 mm. Computer generated camera poses and silhouette views of a full size racket model were used to demonstrate the potential of the method to estimate 3D racket position during a simplified serve scenario. From a camera distance of 14 m, 3D racket position was estimated providing a spatial accuracy of 1.9 ± 0.14 mm, similar to recent 3D video marker tracking studies of tennis

    Making tourist guidance systems more intelligent, adaptive and personalised using crowd sourced movement data

    Get PDF
    Ambient intelligence (AmI) provides adaptive, personalized, intelligent, ubiquitous and interactive services to wide range of users. AmI can have a variety of applications, including smart shops, health care, smart home, assisted living, and location-based services. Tourist guidance is one of the applications where AmI can have a great contribution to the quality of the service, as the tourists, who may not be very familiar with the visiting site, need a location-aware, ubiquitous, personalised and informative service. Such services should be able to understand the preferences of the users without requiring the users to specify them, predict their interests, and provide relevant and tailored services in the most appropriate way, including audio, visual, and haptic. This paper shows the use of crowd sourced trajectory data in the detection of points of interests and providing ambient tourist guidance based on the patterns recognised over such data

    Routes for breaching and protecting genetic privacy

    Full text link
    We are entering the era of ubiquitous genetic information for research, clinical care, and personal curiosity. Sharing these datasets is vital for rapid progress in understanding the genetic basis of human diseases. However, one growing concern is the ability to protect the genetic privacy of the data originators. Here, we technically map threats to genetic privacy and discuss potential mitigation strategies for privacy-preserving dissemination of genetic data.Comment: Draft for comment
    corecore