1,814 research outputs found
Acceleration of cosmic rays and gamma-ray emission from supernova remnants in the Galaxy
Galactic cosmic rays are believed to be accelerated at supernova remnant
shocks. Though very popular and robust, this conjecture still needs a
conclusive proof. The strongest support to this idea is probably the fact that
supernova remnants are observed in gamma-rays, which are indeed expected as the
result of the hadronic interactions between the cosmic rays accelerated at the
shock and the ambient gas. However, also leptonic processes can, in most cases,
explain the observed gamma-ray emission. This implies that the detections in
gamma rays do not necessarily mean that supernova remnants accelerate cosmic
ray protons. To overcome this degeneracy, the multi-wavelength emission (from
radio to gamma rays) from individual supernova remnants has been studied and in
a few cases it has been possible to ascribe the gamma-ray emission to one of
the two processes (hadronic or leptonic). Here we adopt a different approach
and, instead of a case-by-case study we aim for a population study and we
compute the number of supernova remnants which are expected to be seen in TeV
gamma rays above a given flux under the assumption that these objects indeed
are the sources of cosmic rays. The predictions found here match well with
current observational results, thus providing a novel consistency check for the
supernova remnant paradigm for the origin of galactic cosmic rays. Moreover,
hints are presented for the fact that particle spectra significantly steeper
than E^-2 are produced at supernova remnants. Finally, we expect that several
of the supernova remnants detected by H.E.S.S. in the survey of the galactic
plane should exhibit a gamma-ray emission dominated by hadronic processes (i.e.
neutral pion decay). The fraction of the detected remnants for which the
leptonic emission dominates over the hadronic one depends on the assumed values
of the physical parameters and can be as high as roughly a half.Comment: 14 pages, 4 figures, 4 tables, submitted to MNRA
How useful is satellite positioning system (GPS) to track gait parameters? A review.
Over the last century, numerous techniques have been developed to analyze the movement of humans while walking and running. The combined use of kinematics and kinetics methods, mainly based on high speed video analysis and forceplate, have permitted a comprehensive description of locomotion process in terms of energetics and biomechanics. While the different phases of a single gait cycle are well understood, there is an increasing interest to know how the neuro-motor system controls gait form stride to stride. Indeed, it was observed that neurodegenerative diseases and aging could impact gait stability and gait parameters steadiness. From both clinical and fundamental research perspectives, there is therefore a need to develop techniques to accurately track gait parameters stride-by-stride over a long period with minimal constraints to patients. In this context, high accuracy satellite positioning can provide an alternative tool to monitor outdoor walking. Indeed, the high-end GPS receivers provide centimeter accuracy positioning with 5-20 Hz sampling rate: this allows the stride-by-stride assessment of a number of basic gait parameters--such as walking speed, step length and step frequency--that can be tracked over several thousand consecutive strides in free-living conditions. Furthermore, long-range correlations and fractal-like pattern was observed in those time series. As compared to other classical methods, GPS seems a promising technology in the field of gait variability analysis. However, relative high complexity and expensiveness--combined with a usability which requires further improvement--remain obstacles to the full development of the GPS technology in human applications
Do orthopaedic shoes improve local dynamic stability of gait? An observational study in patients with chronic foot and ankle injuries.
BACKGROUND: Complex foot and ankle fractures, such as calcaneum fractures or Lisfranc dislocations, are often associated with a poor outcome, especially in terms of gait capacity. Indeed, degenerative changes often lead to chronic pain and chronic functional limitations. Prescription footwear represents an important therapeutic tool during the rehabilitation process. Local Dynamic Stability (LDS) is the ability of locomotor system to maintain continuous walking by accommodating small perturbations that occur naturally during walking. Because it reflects the degree of control over the gait, LDS has been advocated as a relevant indicator for evaluating different conditions and pathologies. The aim of this study was to analyze changes in LDS induced by orthopaedic shoes in patients with persistent foot and ankle injuries. We hypothesised that footwear adaptation might help patients to improve gait control, which could lead to higher LDS:
METHODS: Twenty-five middle-aged inpatients (5 females, 20 males) participated in the study. They were treated for chronic post-traumatic disabilities following ankle and/or foot fractures in a Swiss rehabilitation clinic. During their stay, included inpatients received orthopaedic shoes with custom-made orthoses (insoles). They performed two 30s walking trials with standard shoes and two 30s trials with orthopaedic shoes. A triaxial motion sensor recorded 3D accelerations at the lower back level. LDS was assessed by computing divergence exponents in the acceleration signals (maximal Lyapunov exponents). Pain was evaluated with Visual Analogue Scale (VAS). LDS and pain differences between the trials with standard shoes and the trials with orthopaedic shoes were assessed.
RESULTS: Orthopaedic shoes significantly improved LDS in the three axes (medio-lateral: 10% relative change, paired t-test pâ<â0.001; vertical: 9%, pâ=â0.03; antero-posterior: 7%, pâ=â0.04). A significant decrease in pain level (VAS score -29%) was observed.
CONCLUSIONS: Footwear adaptation led to pain relief and to improved foot & ankle proprioception. It is likely that that enhancement allows patients to better control foot placement. As a result, higher dynamic stability has been observed. LDS seems therefore a valuable index that could be used in early evaluation of footwear outcome in clinical settings
The Amplitude of Non-Equilibrium Quantum Interference in Metallic Mesoscopic Systems
We study the influence of a DC bias voltage V on quantum interference
corrections to the measured differential conductance in metallic mesoscopic
wires and rings. The amplitude of both universal conductance fluctuations (UCF)
and Aharonov-Bohm effect (ABE) is enhanced several times for voltages larger
than the Thouless energy. The enhancement persists even in the presence of
inelastic electron-electron scattering up to V ~ 1 mV. For larger voltages
electron-phonon collisions lead to the amplitude decaying as a power law for
the UCF and exponentially for the ABE. We obtain good agreement of the
experimental data with a model which takes into account the decrease of the
electron phase-coherence length due to electron-electron and electron-phonon
scattering.Comment: New title, refined analysis. 7 pages, 3 figures, to be published in
Europhysics Letter
SPI Measurements of the Diffuse Galactic Hard X-ray Continuum
INTEGRAL Spectrometer SPI data from the first year of the Galactic Centre
Deep Exposure has been analysed for the diffuse continuum from the Galactic
ridge. A new catalogue of sources from the INTEGRAL Imager IBIS has been used
to account for their contribution to the celestial signal. Apparently diffuse
emission is detected at a level ~10% of the total source flux. A comparison of
the spectrum of diffuse emission with that from an analysis of IBIS data alone
shows that they are consistent. The question of the contribution of unresolved
sources to this ridge emission is still open.Comment: Proceedings of the 5th INTEGRAL Workshop, Munich 16-20 February 2004.
ESA SP-552. Reference to Terrier et al. (2004) updated to include astro-ph
versio
Improvement of walking speed prediction by accelerometry and altimetry, validated by satellite positioning
Activity monitors based on accelerometry are used to predict the speed and energy cost of walking at 0% slope, but not at other inclinations. Parallel measurements of body accelerations and altitude variation were studied to determine whether walking speed prediction could be improved. Fourteen subjects walked twice along a 1.3km circuit with substantial slope variations (â17% to +17%). The parameters recorded were body acceleration using a uni-axial accelerometer, altitude variation using differential barometry, and walking speed using satellite positioning (DGPS). Linear regressions were calculated between acceleration and walking speed, and between acceleration/altitude and walking speed. These predictive models, calculated using the data from the first circuit run, were used to predict speed during the second circuit. Finally the predicted velocity was compared with the measured one. The result was that acceleration alone failed to predict speed (meanr=0.4). Adding altitude variation improved the prediction (meanr=0.7). With regard to the altitude/acceleration-speed relationship, substantial inter-individual variation was found. It is concluded that accelerometry, combined with altitude measurement, can assess position variations of humans provided inter-individual variation is taken into account. It is also confirmed that DGPS can be used for outdoor walking speed measurements, opening up new perspectives in the field of biomechanic
The signature of 44Ti in Cassiopeia A revealed by IBIS/ISGRI on INTEGRAL
We report the detection of both the 67.9 and 78.4 keV 44Sc gamma-ray lines in
Cassiopeia A with the INTEGRAL IBIS/ISGRI instrument. Besides the robustness
provided by spectro-imaging observations, the main improvements compared to
previous measurements are a clear separation of the two 44Sc lines together
with an improved significance of the detection of the hard X-ray continuum up
to 100 keV. These allow us to refine the determination of the 44Ti yield and to
constrain the nature of the nonthermal continuum emission. By combining
COMPTEL, BeppoSAX/PDS and ISGRI measurements, we find a line flux of (2.5 +/-
0.3)*10(-5) cm(-2) s(-1) leading to a synthesized 44Ti mass of 1.6
(+0.6-0.3)*10(-4) solar mass. This high value suggests that Cas A is peculiar
in comparison to other young supernova remnants, from which so far no line
emission from 44Ti decay has been unambiguously detected.Comment: 5 pages, 4 figures, Accepted for publication in ApJ
Persistent fluctuations in stride intervals under fractal auditory stimulation
Copyright @ 2014 Marmelat et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits
unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Stride sequences of healthy gait are characterized by persistent long-range correlations, which become anti-persistent in the presence of an isochronous metronome. The latter phenomenon is of particular interest because auditory cueing is generally considered to reduce stride variability and may hence be beneficial for stabilizing gait. Complex systems tend to match their correlation structure when synchronizing. In gait training, can one capitalize on this tendency by using a fractal metronome rather than an isochronous one? We examined whether auditory cues with fractal variations in inter-beat intervals yield similar fractal inter-stride interval variability as isochronous auditory cueing in two complementary experiments. In Experiment 1, participants walked on a treadmill while being paced by either an isochronous or a fractal metronome with different variation strengths between beats in order to test whether participants managed to synchronize with a fractal metronome and to determine the necessary amount of variability for participants to switch from anti-persistent to persistent inter-stride intervals. Participants did synchronize with the metronome despite its fractal randomness. The corresponding coefficient of variation of inter-beat intervals was fixed in Experiment 2, in which participants walked on a treadmill while being paced by non-isochronous metronomes with different scaling exponents. As expected, inter-stride intervals showed persistent correlations similar to self-paced walking only when cueing contained persistent correlations. Our results open up a new window to optimize rhythmic auditory cueing for gait stabilization by integrating fractal fluctuations in the inter-beat intervals.Commission of the European Community and the Netherlands Organisation for Scientific Research
Treatment of gastrointestinal hemorrhage
Background: We assessed the value of selective arteriography in the diagnosis and management of acute gastrointestinal hemorrhage. Methods: We reviewed the records of 107 consecutive patients who had gastrointestinal hemorrhage and underwent selective arteriography between January 1992 and October 2003: 10 had upper gastrointestinal bleeding, 79 had lower gastrointestinal bleeding, and 18 had varicose bleeding with portal hypertension. Selective embolization was attempted in 15 patients to obtain hemostasis. Angiographic findings were reviewed and prospective reports were compared with the final diagnosis and outcome. Results: Of 129 angiographic studies, 36 correctly revealed the bleeding site and 93 were negative. Extravasation was seen in 24 cases at the level of stomach (n = 2), duodenum (n = 1), small bowel (n = 5), or colon (n = 16). Indirect signs of bleeding sources were identified in 12 patients (stomach in one, small bowel in four, large bowel in four, liver in three). Transcatheter embolization induced definitive hemostasis in 11 of 15 patients (73%), namely in the stomach (n = 2), small bowel (n = 3), colon (n = 7), and liver (n = 3). Three patients required surgery after embolization. Conclusion: Abdominal arteriography may localize gastrointestinal bleeding sources in approximately one-third of cases. Selective embolization may provide definitive hemostasis in most instance
- âŠ