330 research outputs found
Coulomb corrections to the Delbrueck scattering amplitude at low energies
In this article, we study the Coulomb corrections to the Delbrueck scattering
amplitude. We consider the limit when the energy of the photon is much less
than the electron mass. The calculations are carried out in the coordinate
representation using the exact relativistic Green function of an electron in a
Coulomb field. The resulting relative corrections are of the order of a few
percent for scattering on for a large charge of the nucleus. We compare the
corrections with the corresponding ones calculated through the dispersion
integral of the pair production cross section and also with the magnetic loop
contribution to the g-factor of a bound electron. The last one is in a good
agreement with our results but the corrections calculated through the
dispersion relation are not.Comment: 8 pages, 6 figure
Systematic anthropological approach in the treatment of acute and recurrent stages in patients with psoriasis
The article describes a new technology is the treatment of acute and relapsing phases in patients with psoriasis based on the use of multilevel system antropological approach consisting of psychosomatic correction of the patient by methods magnetolaser and neuroacustic stimulation of the central nervous system on the basis of personalized program in combination with compensation aerobic starvation by applying endonasal respiration singlet-oxygen mixture in a magnetic field and a decrease in cutaneous manifestations of pathological changed d on the basis of no injection transdermal administration autoplasma blood by pulsed electrophoresis in a magnetic field
Virtual light-by-light scattering and the g factor of a bound electron
The contribution of the light-by-light diagram to the g factor of electron
and muon bound in Coulomb field is obtained. For electron in a ground state,
our results are in good agreement with the results of other authors obtained
numerically for large Z. For relatively small Z our results have essentially
higher accuracy as compared to the previous ones. For muonic atoms, the
contribution is obtained for the first time with the high accuracy in whole
region of Z.Comment: 10 pages, 3 figures, RevTe
Comparative experimental evaluation of the bactericidal effect of an antiseptic „ANK-neutral”
The article presents the results of an experimental study of the bactericidal action of the disinfectant "ANK-neutral" on bacterial cultures: ESCHERICHIA COLI, KLEBSIELLA PNEUMONIAE, PSEUDOMONAS AERUGINOSA, STAPHYLOCOCCUS AUREUS, CANDIDA ALBICANS. Đžptions for the use of "ANK-neutral" for preventive and therapeutic purposes are proposed
Studies and application of bent crystals for beam steering at 70-GeV IHEP accelerator
This report overviews studies accomplished in the U70 proton synchrotron of
IHEP-Protvino during the recent two decades. Major attention is paid to a
routine application of bent crystals for beam extraction from the machine. It
has been confirmed experimentally that efficiency of beam extraction with a
crystal deflector of around 85% is well feasible for a proton beam with
intensity up to 1012 protons per cycle. Another trend is to use bent crystals
for halo collimation in a high energy collider. New promising options emerge
for, say, LHC and ILC based on the "volume reflection" effect, which has been
discovered recently in machine study runs at U70 of IHEP (50 GeV) and SPS of
CERN (400 GeV).Comment: 12 pages, 14 figure
Crystal experiments on efficient beam extraction
Silicon crystal was channeling and extracting 70-GeV protons from the U-70
accelerator with efficiency of 85.3+-2.8% as measured for a beam of 10^12
protons directed towards crystals of 2 mm length in spills of 1-2 s duration.
The experimental data follow very well the prediction of Monte Carlo
simulations. This success is important to devise a more efficient use of the
U-70 accelerator in Protvino and provides a crucial support for implementation
of crystal-assisted collimation of gold ion beam in RHIC and slow extraction
from AGS onto E952, now in preparation at Brookhaven Nat'l Lab. Future
applications, spanning in the energy from sub-GeV (medical) to order of 1 GeV
(scraping in the SNS, extraction from COSY) to order of 1 TeV and beyond
(scraping in the Tevatron, LHC, VLHC), can benefit from these studies.Comment: 12pp. Presented at 19-th Intern. Conference on Atomic Collisions in
Solids (ICACS-19: Paris, July 29 - August 3, 2001
Progress in crystal extraction and collimation
Recent IHEP Protvino experiments show efficiencies of crystal-assisted slow
extraction and collimation of 85.3+-2.8%, at the intensities of the channeled
beam on the order of 10^12 proton per spill of 2 s duration. The obtained
experimental data well follows the theory predictions. We compare the
measurements against theory and outline the theoretical potential for further
improvement in the efficiency of the technique. This success is important for
the efficient use of IHEP accelerator and for implementation of
crystal-assisted collimation at RHIC and slow extraction from AGS onto E952,
now in preparation. Future applications, spanning in the energy from order of 1
GeV (scraping in SNS, slow extraction from COSY and medical accelerators) to
order of 1 TeV and beyond (scraping in Tevatron, LHC, VLHC), can benefit from
these studies.Comment: 7pp. Presented at HEACC 2001 (Tsukuba, March 25-30
- …