330 research outputs found

    Coulomb corrections to the Delbrueck scattering amplitude at low energies

    Full text link
    In this article, we study the Coulomb corrections to the Delbrueck scattering amplitude. We consider the limit when the energy of the photon is much less than the electron mass. The calculations are carried out in the coordinate representation using the exact relativistic Green function of an electron in a Coulomb field. The resulting relative corrections are of the order of a few percent for scattering on for a large charge of the nucleus. We compare the corrections with the corresponding ones calculated through the dispersion integral of the pair production cross section and also with the magnetic loop contribution to the g-factor of a bound electron. The last one is in a good agreement with our results but the corrections calculated through the dispersion relation are not.Comment: 8 pages, 6 figure

    Systematic anthropological approach in the treatment of acute and recurrent stages in patients with psoriasis

    Get PDF
    The article describes a new technology is the treatment of acute and relapsing phases in patients with psoriasis based on the use of multilevel system antropological approach consisting of psychosomatic correction of the patient by methods magnetolaser and neuroacustic stimulation of the central nervous system on the basis of personalized program in combination with compensation aerobic starvation by applying endonasal respiration singlet-oxygen mixture in a magnetic field and a decrease in cutaneous manifestations of pathological changed d on the basis of no injection transdermal administration autoplasma blood by pulsed electrophoresis in a magnetic field

    Virtual light-by-light scattering and the g factor of a bound electron

    Full text link
    The contribution of the light-by-light diagram to the g factor of electron and muon bound in Coulomb field is obtained. For electron in a ground state, our results are in good agreement with the results of other authors obtained numerically for large Z. For relatively small Z our results have essentially higher accuracy as compared to the previous ones. For muonic atoms, the contribution is obtained for the first time with the high accuracy in whole region of Z.Comment: 10 pages, 3 figures, RevTe

    Comparative experimental evaluation of the bactericidal effect of an antiseptic „ANK-neutral”

    Get PDF
    The article presents the results of an experimental study of the bactericidal action of the disinfectant "ANK-neutral" on bacterial cultures: ESCHERICHIA COLI, KLEBSIELLA PNEUMONIAE, PSEUDOMONAS AERUGINOSA, STAPHYLOCOCCUS AUREUS, CANDIDA ALBICANS. Đžptions for the use of "ANK-neutral" for preventive and therapeutic purposes are proposed

    Studies and application of bent crystals for beam steering at 70-GeV IHEP accelerator

    Full text link
    This report overviews studies accomplished in the U70 proton synchrotron of IHEP-Protvino during the recent two decades. Major attention is paid to a routine application of bent crystals for beam extraction from the machine. It has been confirmed experimentally that efficiency of beam extraction with a crystal deflector of around 85% is well feasible for a proton beam with intensity up to 1012 protons per cycle. Another trend is to use bent crystals for halo collimation in a high energy collider. New promising options emerge for, say, LHC and ILC based on the "volume reflection" effect, which has been discovered recently in machine study runs at U70 of IHEP (50 GeV) and SPS of CERN (400 GeV).Comment: 12 pages, 14 figure

    Crystal experiments on efficient beam extraction

    Get PDF
    Silicon crystal was channeling and extracting 70-GeV protons from the U-70 accelerator with efficiency of 85.3+-2.8% as measured for a beam of 10^12 protons directed towards crystals of 2 mm length in spills of 1-2 s duration. The experimental data follow very well the prediction of Monte Carlo simulations. This success is important to devise a more efficient use of the U-70 accelerator in Protvino and provides a crucial support for implementation of crystal-assisted collimation of gold ion beam in RHIC and slow extraction from AGS onto E952, now in preparation at Brookhaven Nat'l Lab. Future applications, spanning in the energy from sub-GeV (medical) to order of 1 GeV (scraping in the SNS, extraction from COSY) to order of 1 TeV and beyond (scraping in the Tevatron, LHC, VLHC), can benefit from these studies.Comment: 12pp. Presented at 19-th Intern. Conference on Atomic Collisions in Solids (ICACS-19: Paris, July 29 - August 3, 2001

    Progress in crystal extraction and collimation

    Get PDF
    Recent IHEP Protvino experiments show efficiencies of crystal-assisted slow extraction and collimation of 85.3+-2.8%, at the intensities of the channeled beam on the order of 10^12 proton per spill of 2 s duration. The obtained experimental data well follows the theory predictions. We compare the measurements against theory and outline the theoretical potential for further improvement in the efficiency of the technique. This success is important for the efficient use of IHEP accelerator and for implementation of crystal-assisted collimation at RHIC and slow extraction from AGS onto E952, now in preparation. Future applications, spanning in the energy from order of 1 GeV (scraping in SNS, slow extraction from COSY and medical accelerators) to order of 1 TeV and beyond (scraping in Tevatron, LHC, VLHC), can benefit from these studies.Comment: 7pp. Presented at HEACC 2001 (Tsukuba, March 25-30
    • …
    corecore