73 research outputs found

    Mouse visual cortex contains a region of enhanced spatial resolution.

    Get PDF
    The representation of space in mouse visual cortex was thought to be relatively uniform. Here we reveal, using population receptive-field (pRF) mapping techniques, that mouse visual cortex contains a region in which pRFs are considerably smaller. This region, the "focea," represents a location in space in front of, and slightly above, the mouse. Using two-photon imaging we show that the smaller pRFs are due to lower scatter of receptive-fields at the focea and an over-representation of binocular regions of space. We show that receptive-fields of single-neurons in areas LM and AL are smaller at the focea and that mice have improved visual resolution in this region of space. Furthermore, freely moving mice make compensatory eye-movements to hold this region in front of them. Our results indicate that mice have spatial biases in their visual processing, a finding that has important implications for the use of the mouse model of vision

    Recovery of Absolute Coronary Blood Flow and Microvascular Resistance After Chronic Total Occlusion Percutaneous Coronary Intervention: An Exploratory Study

    Get PDF
    Background: This study aimed to investigate longitudinal physiological changes in the recanalized coronary chronic total occlusion (CTO) vessel and its dependent myocardium after successful percutaneous coronary intervention (PCI). Methods and Results: In this pilot study, 25 patients scheduled for elective CTO PCI with viable myocardium and angiographically visible collaterals were included. Absolute coronary blood flow and absolute microvascular resistance were measured invasively using continuous thermodilution. Measurements were performed immediately after successful CTO PCI and at short‐term follow‐up. In a subgroup of patients, physiological measurements were performed at the predominant donor vessel before CTO PCI, immediately afterwards, and at follow‐up. Absolute coronary blood flow in the recanalized CTO artery increased from 148±53 mL/min immediately after PCI to 221±77 mL/min at follow‐up (P<0.001). In agreement, absolute resistance in the myocardial territory perfused by the CTO artery, decreased from 545±255 Wood units immediately after the procedure to 387±128 Wood units at follow‐up (P=0.014). There were no significant changes in the absolute coronary blood flow and resistance in the predominant donor between baseline and follow‐up. Positive remodeling of the distal CTO vessel with an increase in lumen diameter was observed. Conclusions: After successful CTO PCI, blood flow in the recanalized artery and microvascular function of the dependent myocardium are not immediately normal but recover over time

    Predictive Value of POSSUM and ACPGBI Scoring in Mortality and Morbidity of Colorectal Resection: A Case–Control Study

    Get PDF
    Contains fulltext : 97239.pdf (publisher's version ) (Open Access)BACKGROUND: Preoperative risk prediction to assess mortality and morbidity may be helpful to surgical decision making. The aim of this study was to compare mortality and morbidity of colorectal resections performed in a tertiary referral center with mortality and morbidity as predicted with physiological and operative score for enumeration of mortality and morbidity (POSSUM), Portsmouth POSSUM (P-POSSUM), and colorectal POSSUM (CR-POSSUM). The second aim of this study was to analyze the accuracy of different POSSUM scores in surgery performed for malignancy, inflammatory bowel diseases, and diverticulitis. POSSUM scoring was also evaluated in colorectal resection in acute vs. elective setting. In procedures performed for malignancy, the Association of Coloproctology of Great Britain and Ireland (ACPGBI) score was assessed in the same way for comparison. METHODS: POSSUM, P-POSSUM, and CR-POSSUM predictor equations for mortality were applied in a retrospective case-control study to 734 patients who had undergone colorectal resection. The total group was assessed first. Second, the predictive value of outcome after surgery was assessed for malignancy (n = 386), inflammatory bowel diseases (n = 113), diverticulitis (n = 91), and other indications, e.g., trauma, endometriosis, volvulus, or ischemia (n = 144). Third, all subgroups were assessed in relation to the setting in which surgery was performed: acute or elective. In patients with malignancy, the ACPGBI score was calculated as well. In all groups, receiver operating characteristic (ROC) curves were constructed. RESULTS: POSSUM, P-POSSUM, and CR-POSSUM have a significant predictive value for outcome after colorectal surgery. Within the total population as well as in all four subgroups, there is no difference in the area under the curve between the POSSUM, P-POSSUM, and CR-POSSUM scores. In the subgroup analysis, smallest areas under the ROC curve are seen in operations performed for malignancy, which is significantly worse than for diverticulitis and in operations performed for other indications. For elective procedures, P-POSSUM and CR-POSSUM predict outcome significantly worse in patients operated for carcinoma than in patients with diverticulitis. In acute surgical interventions, CR-POSSUM predicts mortality better in diverticulitis than in patients operated for other indications. The ACPGBI score has a larger area under the curve than any of the POSSUM scores. Morbidity as predicted by POSSUM is most accurate in procedures for diverticulitis and worst when the indication is malignancy. CONCLUSION: The POSSUM scores predict outcome significantly better than can be expected by chance alone. Regarding the indication for surgery, each POSSUM score predicts outcome in patients operated for diverticulitis or other indications more accurately than for malignancy. The ACPGBI score is found to be superior to the various POSSUM scores in patients who have (elective) resection of colorectal malignancy

    Minimal information for studies of extracellular vesicles (MISEV2023): From basic to advanced approaches

    Get PDF
    Extracellular vesicles (EVs), through their complex cargo, can reflect the state of their cell of origin and change the functions and phenotypes of other cells. These features indicate strong biomarker and therapeutic potential and have generated broad interest, as evidenced by the steady year-on-year increase in the numbers of scientific publications about EVs. Important advances have been made in EV metrology and in understanding and applying EV biology. However, hurdles remain to realising the potential of EVs in domains ranging from basic biology to clinical applications due to challenges in EV nomenclature, separation from non-vesicular extracellular particles, characterisation and functional studies. To address the challenges and opportunities in this rapidly evolving field, the International Society for Extracellular Vesicles (ISEV) updates its 'Minimal Information for Studies of Extracellular Vesicles', which was first published in 2014 and then in 2018 as MISEV2014 and MISEV2018, respectively. The goal of the current document, MISEV2023, is to provide researchers with an updated snapshot of available approaches and their advantages and limitations for production, separation and characterisation of EVs from multiple sources, including cell culture, body fluids and solid tissues. In addition to presenting the latest state of the art in basic principles of EV research, this document also covers advanced techniques and approaches that are currently expanding the boundaries of the field. MISEV2023 also includes new sections on EV release and uptake and a brief discussion of in vivo approaches to study EVs. Compiling feedback from ISEV expert task forces and more than 1000 researchers, this document conveys the current state of EV research to facilitate robust scientific discoveries and move the field forward even more rapidly

    The IAIS Survey on Reinsurance Supervision An Overview of the Findings

    No full text
    At the Third Annual Conference of the International Association of Insurance Supervisors (IAIS) held in Paris, in October 1996, one of the items of the Conference was a Panel Session on reinsurance and supervision. Chairing this session, the Verzekeringskamer (the Dutch Insurance Supervisory Authority) focused on how reinsurance supervision is practised in a number of IAIS countries. Moreover, these countries were invited to give their opinion about the future supervision on reinsurance. At the end of the Panel Session, the Verzekeringskamer invited all members of the IAIS to fill in a questionnaire on this subject in due course.At the Fourth Annual Conference, in Sydney Australia, in September 1997, the results of a research project were made public. This article is a slightly adapted version of the paper that was presented in Sydney.The main results indicate that the IAIS members expect a somewhat stricter supervision of reinsurers than at present. The existing differences in supervisory approach between the countries will narrow, but will not disappear altogether.

    Inversion of pop-out for a distracting feature dimension in monkey visual cortex

    Get PDF
    During visual search, it is important to reduce the interference of distracting objects in the scene. The neuronal responses elicited by the search target stimulus are typically enhanced. However, it is equally important to suppress the representations of distracting stimuli, especially if they are salient and capture attention. We trained monkeys to make an eye movement to a unique "pop-out" shape stimulus among an array of distracting stimuli. One of these distractors had a salient color that varied across trials and differed from the color of the other stimuli, causing it to also pop-out. The monkeys were able to select the pop-out shape target with high accuracy and actively avoided the pop-out color distractor. This behavioral pattern was reflected in the activity of neurons in area V4. Responses to the shape targets were enhanced, while the activity evoked by the pop-out color distractor was only briefly enhanced, directly followed by a sustained period of pronounced suppression. These behavioral and neuronal results demonstrate a cortical selection mechanism that rapidly inverts a pop-out signal to "pop-in" for an entire feature dimension thereby facilitating goal-directed visual search in the presence of salient distractors

    Spectral analysis criteria in duplex scanning of aortoiliac and femoropopliteal arterial disease

    No full text
    To validate the use of duplex scanning in the detection of lesions in the aortoiliac and femoropopliteal arteries, duplex scanning was prospectively compared to intra-arterial digital subtraction angiography in 61 patients with peripheral atherosclerotic disease. Based on a peak systolic velocity ratio greater than or equal to 2.5 or the absence of a Doppler signal, the overall sensitivity and specificity to detect lesions of greater than or equal to 50% diameter reduction was 84% and 96%, although some segments in the femoropopliteal arteries showed a sensitivity of only 60%-70%. Occlusions were detected with an overall sensitivity of 92% and specificity of 99%. The existence of a bi/triphasic Doppler signal, a window in the systolic spectral waveform and an end diastolic velocity greater than or equal to 60 cm/s has additional value in further grading of stenoses. This study shows that duplex scanning is highly comparable to angiography in the detection greater than or equal to 50% diameter reducing lesions in the aortoiliac arteries. Further evaluation is needed for the femoropopliteal arterie
    corecore