95 research outputs found

    Using Informatics to Improve Autism Screening in a Pediatric Primary Care Practice

    Get PDF
    Background: According to the most recent report from the CDC (2018), autism spectrum disorder (ASD) affects approximately one in 59 children in the United States (U.S.). In 2007, the American Academy of Pediatrics (AAP) issued a strong recommendation for all primary care providers to screen children for autism, using a validated tool, at the 18 and 24-month well-child visits, in order to begin the referral process for more formal testing, and intervention, promptly. Despite the strong stance of the AAP and evidence supporting the importance of early intervention for children with ASD, not all primary care providers are screening for ASD or developmental delay. Purpose: To improve the percentage of eligible children, presenting for 18 and 24 month wellchild visits in a pediatric primary care office, who are screened for ASD, by integrating the Modified Checklist for Autism in Toddlers (M-CHAT) screening tool into the electronic medical record with tablets. The specific aims were to increase the percentage of children screened and improve the documentation of the screens performed. Methods: This quality improvement project utilized a before-after quantitative design to support the improvement. Reports were obtained for three months prior to the implementation of the tablets and process change, and again for three months following the implementation. Manual chart reviews were also performed to verify the data from the reports. The definition used for complete screening for this project included 1) presence of the completed screen in the medical record, 2) provider documentation of the result, interpretation, and plan if indicated, and 3) CPT code entry for charge capture completed in the electronic medical record. Results: The results of the project revealed improvements in overall percentages of eligible children screened for autism at D-H Nashua Pediatrics. The percentage of complete screening increased from 64.7% to 73.9% following the implementation of the project, a change which is statistically significant (t=31.6105, df=16,p=0.05). Each individual element was also tracked and those results showed that 1) the completeness of provider documentation related to the screening increased from 93.6% to 96% (t=41.3321, df=16, p=0.05) and 2) the M-CHAT screen was present in the electronic health record (EHR) 98.9% of the time, which was an increase from 84.6% (t=295.4084, df=16, p=0.05). The charge capture completion rate remained statistically unchanged at 76.5% (t=0.4664, df=16, p=0.05). Additionally, only one screening was noted to be missed altogether, out of 280 eligible children. Prior to the project, there were four missed screenings (out of 156 eligible children) captured by the chart reviews conducted over three months prior to the implementation of the project. Overall, the results show that the project resulted in an increase the percentage of M-CHAT screening, an increase in the presence of source documentation in the electronic health record (EHR), and more complete provider documentation related to the screening

    An Overview of the Utilization of a University Health Center

    Get PDF
    Background: College students often do not visit university health centers or attend scheduled appointments. Missed appointments affect not only the students’ health, but also the health center. Missed appointments cannot be easily rescheduled, limit appointment times for others, and lead to a higher cost for the university. The purpose of this study is to explore student usage of a university based health care center. Method: A retrospective review of 400 electronic health records, from college students enrolled in a State University from 2016-2017, were examined. The information collected focused on the use of the university health center, reason for appointment, time of appointment, and whether or not the student attended the appointment. Results: Data collection is currently ongoing. Discussion: A study was performed to determine the reason for use and lack of use of health centers, and the factors that influence them. Conclusion: Studies show a common trend in campus health center utilization, such as for mental health services. As the number of students who need mental health service increases, it is crucial to improve the current availability of services. Among students who did not utilize campus health center services report due to long waiting times, inability to establish rapport, inadequate experience of medical staff, and stigma

    No Evidence of Avian Influenza A H5N1 among Returning US Travelers

    Get PDF
    We reviewed reports to the Centers for Disease Control and Prevention of US travelers suspected of having avian influenza A H5N1 virus infection from February 2003 through May 2006. Among the 59 reported patients, no evidence of H5N1 virus infection was found; none had had direct contact with poultry, but 42% had evidence of human influenza A

    Telephone Triage Service Data for Detection of Influenza-Like Illness

    Get PDF
    Background: Surveillance for influenza and influenza-like illness (ILI) is important for guiding public health prevention programs to mitigate the morbidity and mortality caused by influenza, including pandemic influenza. Nontraditional sources of data for influenza and ILI surveillance are of interest to public health authorities if their validity can be established. Methods/Principal Findings: National telephone triage call data were collected through automated means for purposes of syndromic surveillance. For the 17 states with at least 500,000 inhabitants eligible to use the telephone triage services, call volume for respiratory syndrome was compared to CDC weekly number of influenza isolates and percentage of visits to sentinel providers for ILI. The degree to which the call data were correlated with either CDC viral isolates or sentinel provider percentage ILI data was highly variable among states. Conclusions: Telephone triage data in the U.S. are patchy in coverage and therefore not a reliable source of ILI surveillance data on a national scale. However, in states displaying a higher correlation between the call data and the CDC data, call data may be useful as an adjunct to state-level surveillance data, for example at times when sentinel surveillance is not in operation or in areas where sentinel provider coverage is considered insufficient. Sufficient population coverage, a specific ILI syndrome definition, and the use of a threshold of percentage of calls that are for ILI would likely improve the utility of such data for ILI surveillance purposes

    CT Analysis of the Anterior Mediastinum in Idiopathic Pulmonary Fibrosis and Nonspecific Interstitial Pneumonia

    Get PDF
    OBJECTIVE: We wanted to determine whether the amount and shape of the anterior mediastinal fat in the patients suffering with usual interstitial pneumonia (UIP) or nonspecific interstitial pneumonia (NSIP) was different from those of the normal control group. MATERIALS AND METHODS: We selected patients who suffered with UIP (n = 26) and NSIP (n = 26) who had undergone CT scans. Twenty-six controls were selected from individuals with normal CT findings and normal pulmonary function tests. All three groups (n = 78) were individually matched for age and gender. The amounts of anterior mediastinal fat, and the retrosternal anteroposterior (AP) and transverse dimensions of the anterior mediastinal fat were compared by one-way analysis of variance and Bonferroni's test. The shapes of the anterior mediastinum were compared using the Chi-square test. Exact logistic regression analysis and polychotomous logistic regression analysis were employed to assess whether the patients with NSIP or UIP had a tendency to show a convex shape of their anterior mediastinal fat. RESULTS: The amount of anterior mediastinal fat was not different among the three groups (p = 0.175). For the UIP patients, the retrosternal AP dimension of the anterior mediastinal fat was shorter (p = 0.037) and the transverse dimension of the anterior mediastinal fat was longer (p = 0.001) than those of the normal control group. For the NSIP patients, only the transverse dimension was significantly longer than those of the normal control group (p < 0.001). The convex shape of the anterior mediastinum was predictive of NSIP (OR = 19.7, CI 3.32-infinity, p < 0.001) and UIP (OR = 24.42, CI 4.06-infinity, p < 0.001). CONCLUSION: For UIP patients, the retrosternal AP and transverse dimensions are different from those of normal individuals, whereas the amounts of anterior mediastinal fat are similar. UIP and NSIP patients have a tendency to have a convex shape of their anterior mediastinal fat.This study is supported by KISTEP, the Ministry of Science and Technology, Korea

    Tomographic renal cortical scintigraphy: Correlation with intravenous urography, computed tomography, ultrasonography, angiography, and nuclear magnetic resonance imaging

    Full text link
    This study evaluates single-photon renal tomoscintigraphy (SPECT) in the evaluation of renal masses and correlates this modality, where indicated, with computed tomography (CT), ultrasonography (US), angiography (ANGIO) and nuclear magnetic resonance imaging (NMR). Eight patients with renal cortical lesions detected on intravenous urography (IVP) were evaluated by SPECT and planar nuclear imaging using Tc-99m glucoheptonate (GH). Three of these patients were felt particularly likely to have renal tumors and were additionally evaluated with US, CT, ANGIO and NMR. The five patients with nodules on IVP that were not particularly suggestive of malignancy had functioning, benign, renal tissue accounting for their IVP lesions. Four of five were found by planar-GH nuclear imaging, five/five by SPECT-GH. In addition, SPECT-GH allowed better “confidence” in the normal renal tissue diagnosis in three/five cases. Of the three renal lesions that were highly suggestive of malignancy, two were hypernephromas and one was hypertrophied functioning cortical tissue. All three were correctly identified prospectively on SPECT-GH; however, one hypernephroma was missed on planar-GH. NMR, CT, and ANGIO detected only one of two hypernephromas prospectively (US detected both); all four modalities incorrectly diagnosed the hypertrophied tissue suggestive of malignancy.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/46822/1/259_2004_Article_BF00279072.pd

    The Navy embedded computer accreditation study

    Get PDF
    Issued as Final technical report, Project A-248

    Condensing Osteitis Of The Clavicle

    No full text
    corecore