912 research outputs found

    A temporal approach for morphological indices of the common sole (Solea solea Linnaeus 1758) from the coast of the Aegean Sea, Turkey

    Get PDF
    810-818Temporal changes of the morphological indices (Relative Gut Length (RGL), Fullness Index (FI), Hepatosomatic Index (HSI), Visceral Index (VSI), Gonadosomatic Index (GSI) and Fulton condition)) in 122 (♀: 94, ♂: 19, immature: 9) common sole were evaluated. Total length-weight relationships were calculated as W = 0.085TL3.01 and W = 0.0547TL2.40 in females and males, respectively, whereby isometric growth was observed in females and negative allometric growth was observed in males. While there was no statistically significant difference was observed between the FI, HSI, Viscerosomatic Index (VSI), RGL and GSI values of both sexes, however, there was a statistically significant difference in terms of Fulton K values (P < 0.05). In addition, there are statistical differences between the sexes total lengths and the values of RGL, FI, HSI, VSI, and Fulton-K (P < 0.05), as it is discernible in their HSI and VSI index values according to the month the specimens were obtained (P < 0.05). According to the results of the analysis, it has been determined that the female common sole along the Aegean coast adjust their energy temporally and store the energy they obtain from vegetative and carnivorous feeding. Contrary to the situation seen in females, the male individuals invest in energy through omnivorous feeding, according to the diet in the active process. Based on the results, it can be stated that the VSI and HSI are both important indicators of fish condition status. The results found here may be useful in both fishery research and fishery management

    A temporal approach for morphological indices of the common sole (Solea solea Linnaeus 1758) from the coast of the Aegean Sea, Turkey

    Get PDF
    Temporal changes of the morphological indices (Relative Gut Length (RGL), Fullness Index (FI), Hepatosomatic Index (HSI), Visceral Index (VSI), Gonadosomatic Index (GSI) and Fulton condition)) in 122 (♀: 94, ♂: 19, immature: 9) common sole were evaluated. Total length-weight relationships were calculated as W = 0.085TL3.01 and W = 0.0547TL2.40 in females and males, respectively, whereby isometric growth was observed in females and negative allometric growth was observed in males. While there was no statistically significant difference was observed between the FI, HSI, Viscerosomatic Index (VSI), RGL and GSI values of both sexes, however, there was a statistically significant difference in terms of Fulton K values (P &lt; 0.05). In addition, there are statistical differences between the sexes total lengths and the values of RGL, FI, HSI, VSI, and Fulton-K (P &lt; 0.05), as it is discernible in their HSI and VSI index values according to the month the specimens were obtained (P &lt; 0.05). According to the results of the analysis, it has been determined that the female common sole along the Aegean coast adjust their energy temporally and store the energy they obtain from vegetative and carnivorous feeding. Contrary to the situation seen in females, the male individuals invest in energy through omnivorous feeding, according to the diet in the active process. Based on the results, it can be stated that the VSI and HSI are both important indicators of fish condition status. The results found here may be useful in both fishery research and fishery management

    Identification of tandem repeat families from long-read sequences of Humulus lupulus

    Full text link
    Hop (Humulus lupulus L.) is known for its use as a bittering agent in beer and has a rich history of cultivation, beginning in Europe and now spanning the globe. There are five wild varieties worldwide, which may have been introgressed with cultivated varieties. As a dioecious species, its obligate outcrossing, non-Mendelian inheritance, and genomic structural variability have confounded directed breeding efforts. Consequently, understanding the hop genome represents a considerable challenge, requiring additional resources. In order to facilitate investigations into the transmission genetics of hop, we report here a tandem repeat discovery pipeline developed using k-mer filtering and dot plot analysis of PacBio long-read sequences from the hop cultivar Apollo. From this we identified 17 new and distinct tandem repeat sequence families, which represent candidates for FISH probe development. For two of these candidates, HuluTR120 and HuluTR225, we produced oligonucleotide FISH probes from conserved regions of and demonstrated their utility by staining meiotic chromosomes from wild hop, var. neomexicanus to address, for example, questions about hop transmission genetics. Collectively, these tandem repeat sequence families represent new resources suitable for development of additional cytogenomic tools for hop research

    Razvoj i vrednovanje dvoslojnih tableta propranolol hidroklorida

    Get PDF
    The objective of the present research was to develop a bilayer tablet of propranolol hydrochloride using superdisintegrant sodium starch glycolate for the fast release layer and water immiscible polymers such as ethyl cellulose, Eudragit RLPO and Eudragit RSPO for the sustaining layer. In vitro dissolution studies were carried out in a USP 24 apparatus I. The formulations gave an initial burst effect to provide the loading dose of the drug followed by sustained release for 12 hrs from the sustaining layer of matrix embedded tablets. In vitro dissolution kinetics followed the Higuchi model via a non-Fickian diffusion controlled release mechanism after the initial burst release. FT-IR studies revealed that there was no interaction between the drug and polymers used in the study. Statistical analysis (ANOVA) showed no significant difference in the cumulative amount of drug release after 15 min, but significant difference (p 0.005) in the amount of drug released after 12 h from optimized formulations was observed.U radu je opisan razvoj dvoslojnih tableta propranolol hidroklorida, koristeći superdezintegrator škrob glikolat natrij u sloju za brzo oslobađanje i polimere koji se ne miješaju s vodom (etil celuloza, Eudragit RLPO i Eudragit RSPO) u sloju za usporeno oslobađanje. In vitro oslobađanje praćeno je u USP aparatu I te je uočeno početno naglo oslobađanje ljekovite tvari iza kojeg slijedi polagano oslobađanje tijekom 12 sati. In vitro kinetika oslobađanja prati Higouchijev model, dok mehanizam kontroliranog oslobađanja ne slijedi Fickov zakon poslije početnog naglog oslobađanja. FT-IR studije ukazuju da nema interakcije između ljekovite tvari i polimera upotrebljenih u oblikovanju. Statistička analiza (ANOVA) nije pokazala značajne razlike u kumulativnoj količini oslobođenog lijeka iz optimiranih formulacija poslije 15 minuta i polije 12 h

    Enhanced control of the ionization rate in radio-frequency plasmas with structured electrodes via tailored voltage waveforms

    Get PDF
    International audienceRadio-frequency capacitively coupled plasmas that incorporate structured electrodes enable increases in the electron density within spatially localized regions through the hollow cathode effect (HCE). This enables enhanced control over the spatial profile of the plasma density, which is useful for several applications including materials processing, lighting and spacecraft propulsion. However, asymmetries in the powered and grounded electrode areas inherent to the hollow cathode geometry lead to the formation of a time averaged dc self-bias voltage at the powered electrode. This bias alters the energy and flux of secondary electrons leaving the surface of the cathode and consequentially can moderate the increased localized ionization afforded by the hollow cathode discharge. In this work, two-dimensional fluid-kinetic simulations are used to demonstrate control of the dc self-bias voltage in a dual-frequency driven (13.56, 27.12 MHz), hollow cathode enhanced, capacitively coupled argon plasma over the 66.6--200 Pa (0.5--1.5 Torr) pressure range. By varying the phase offset of the 27.12 MHz voltage waveform, the dc self-bias voltage varies by 10%--15% over an applied peak-to-peak voltage range of 600--1000 V, with lower voltages showing higher modulation. Resulting ionization rates due to secondary electrons within the hollow cathode cavity vary by a factor of 3 at constant voltage amplitude, demonstrating the ability to control plasma properties relevant for maintaining and enhancing the HCE

    Design, Performance and Calibration of the CMS Forward Calorimeter Wedges

    Get PDF
    We report on the test beam results and calibration methods using charged particles of the CMS Forward Calorimeter (HF). The HF calorimeter covers a large pseudorapidity region (3\l |\eta| \le 5), and is essential for large number of physics channels with missing transverse energy. It is also expected to play a prominent role in the measurement of forward tagging jets in weak boson fusion channels. The HF calorimeter is based on steel absorber with embedded fused-silica-core optical fibers where Cherenkov radiation forms the basis of signal generation. Thus, the detector is essentially sensitive only to the electromagnetic shower core and is highly non-compensating (e/h \approx 5). This feature is also manifest in narrow and relatively short showers compared to similar calorimeters based on ionization. The choice of fused-silica optical fibers as active material is dictated by its exceptional radiation hardness. The electromagnetic energy resolution is dominated by photoelectron statistics and can be expressed in the customary form as a/\sqrt{E} + b. The stochastic term a is 198% and the constant term b is 9%. The hadronic energy resolution is largely determined by the fluctuations in the neutral pion production in showers, and when it is expressed as in the electromagnetic case, a = 280% and b = 11%

    Design, Performance, and Calibration of CMS Hadron Endcap Calorimeters

    Get PDF
    Detailed measurements have been made with the CMS hadron calorimeter endcaps (HE) in response to beams of muons, electrons, and pions. Readout of HE with custom electronics and hybrid photodiodes (HPDs) shows no change of performance compared to readout with commercial electronics and photomultipliers. When combined with lead-tungstenate crystals, an energy resolution of 8\% is achieved with 300 GeV/c pions. A laser calibration system is used to set the timing and monitor operation of the complete electronics chain. Data taken with radioactive sources in comparison with test beam pions provides an absolute initial calibration of HE to approximately 4\% to 5\%
    • …
    corecore