4,818 research outputs found

    Guided Tissue Remineralization of Resin-Bonded Acid-Etched Dentin

    Get PDF
    Contemporary biomineralization strategies incorporate non-classical crystallization pathways of fluidic amorphous nanoprecursors and mesoscopic transformation. Using two functional biomimetic molecules, we previously regenerated mineralized dentin from acid-etched dentin using the Guided Tissue Remineralization (GTR) approach, with definitive intrafibrillar remineralization of type-I collagen. Degradation of denuded collagen within dentin adhesive resin-infiltrated dentin is a pertinent problem in dentin bonding. Here, we show that GTR provides a means of salvaging these degrading bonds by remineralizing resin-dentin interfaces. The GTR medium consists of a Portland cement/simulated body fluid that includes polyacrylic acid and polyvinylphosphonic acid biomimetic analogs for amorphous calcium phosphate dimension regulation and collagen targeting. Both interfibrillar and intrafibrillar apatites became readily discernible within the adhesive-bonded dentin after 2-4 months. Amorphous nanoprecursors created by GTR also penetrated the adhesive resin matrix to create nanocomposites. We anticipate GTR to be the starting point for more sophisticated strategies in extending the longevity of resin-dentin bonds

    Quantum limited particle sensing in optical tweezers

    Get PDF
    Particle sensing in optical tweezers systems provides information on the position, velocity and force of the specimen particles. The conventional quadrant detection scheme is applied ubiquitously in optical tweezers experiments to quantify these parameters. In this paper we show that quadrant detection is non-optimal for particle sensing in optical tweezers and propose an alternative optimal particle sensing scheme based on spatial homodyne detection. A formalism for particle sensing in terms of transverse spatial modes is developed and numerical simulations of the efficacy of both quadrant and spatial homodyne detection are shown. We demonstrate that an order of magnitude improvement in particle sensing sensitivity can be achieved using spatial homodyne over quadrant detection.Comment: Submitted to Biophys

    Effect of smear layers on bonding of a self-etching primer to dentin

    Get PDF
    Abstract no. 1702published_or_final_versio

    Quantitative Assessment of the Anatomical Footprint of the C1 Pedicle Relative to the Lateral Mass: A Guide for C1 Lateral Mass Fixation

    Get PDF
    Study Design: Anatomic study. Objectives: To determine the relationship of the anatomical footprint of the C1 pedicle relative to the lateral mass (LM). Methods: Anatomic measurements were made on fresh frozen human cadaveric C1 specimens: pedicle width/height, LM width/height (minimum/maximum), LM depth, distance between LM’s medial aspect and pedicle’s medial border, distance between LM’s lateral aspect to pedicle’s lateral border, distance between pedicle’s inferior aspect and LM’s inferior border, distance between arch’s midline and pedicle’s medial border. The percentage of LM medial to the pedicle and the distance from the center of the LM to the pedicle’s medial wall were calculated. Results: A total of 42 LM were analyzed. The C1 pedicle’s lateral aspect was nearly confluent with the LM’s lateral border. Average pedicle width was 9.0 ± 1.1 mm, and average pedicle height was 5.0 ± 1.1 mm. Average LM width and depth were 17.0 ± 1.6 and 17.2 ± 1.6 mm, respectively. There was 6.9 ± 1.5 mm of bone medial to the medial C1 pedicle, which constituted 41% ± 9% of the LM’s width. The distance from C1 arch’s midline to the medial pedicle was 13.5 ± 2.0 mm. The LM’s center was 1.6 ± 1 mm lateral to the medial pedicle wall. There was on average 3.5 ± 0.6 mm of the LM inferior to the pedicle inferior border. Conclusions: The center of the lateral mass is 1.6 ± 1 mm lateral to the medial wall of the C1 pedicle and approximately 15 mm from the midline. There is 6.9 ± 1.5 mm of bone medial to the medial C1 pedicle. Thus, the medial aspect of C1 pedicle may be used as an anatomic reference for locating the center of the C1 LM for screw fixation

    Some Notes on the Malayan Law of Negligence

    Get PDF
    In the annals of the spread of the common law to other lands and other ways, Malaya may deserve a modest place, but, as the selection here no doubt shows, so far it has made no significant contribution to the intellectual content of that law. It has neither produced nor harboured a Cardozo or a Dixon. At best, its judges have applied common law principles simply but soundly; they have never, at least in tort, been subtle or illuminating. Its legal history is of interest for its own sake; its legal achievement awaits us in the future, not in the past

    The Learner’s Engagement in the Learning Process designed based on the Experiential Learning theory in Post Graduate Program at Open University Malaysia

    Get PDF
    The purpose of this study was to: 1. observe the level of engagement in a learning process in ‘grasp experience’ and ‘transform experience’ section. 2. evaluate the level of engagement in an online forum between ‘grasp experience’ and ‘transform experience’ section. 3. clarify the level of engagement through the posting in an online forum, which reflects the actual ‘experience.
    corecore