14 research outputs found

    Preliminary assessment of the feasibility of using AB words to assess candidacy in adults

    Get PDF
    Background: Adult cochlear implant (CI) candidacy is assessed in part by the use of speech perception measures. In the United Kingdom the current cut-off point to fall within the CI candidacy range is a score of less than 50% on the BKB sentences presented in quiet (presented at 70 dBSPL). Goal: The specific goal of this article was to review the benefit of adding the AB word test to the assessment test battery for candidacy. Results: The AB word test scores showed good sensitivity and specificity when calculated based on both word and phoneme scores. The word score equivalent for 50% correct on the BKB sentences was 18.5% and it was 34.5% when the phoneme score was calculated; these scores are in line with those used in centres in Wales (15% AB word score). Conclusion: The goal of the British Cochlear Implant Group (BCIG) service evaluation was to determine if the pre-implant assessment measures are appropriate and set at the correct level for determining candidacy, the future analyses will determine whether the speech perception cut-off point for candidacy should be adjusted and whether other more challenging measures should be used in the candidacy evaluation

    Cognitive Improvement After Cochlear Implantation in Older Adults With Severe or Profound Hearing Impairment: A Prospective, Longitudinal, Controlled, Multicenter Study

    Get PDF
    Objective: To compare the cognitive evolution of older adults with severe or profound hearing impairment after cochlear implantation with that of a matched group of older adults with severe hearing impairment who do not receive a cochlear implant (CI).Design: In this prospective, longitudinal, controlled, and multicenter study, 24 older CI users were included in the intervention group and 24 adults without a CI in the control group. The control group matched the intervention group in terms of gender, age, formal education, cognitive functioning, and residual hearing. Assessments were made at baseline and 14 months later. Primary outcome measurements included the change in the total score on the Repeatable Battery for the Assessment of Neuropsychological Status for Hearing impaired individuals score and on its subdomain score to assess cognitive evolution in both groups. Secondary outcome measurements included self-reported changes in sound quality (Hearing Implant Sound Quality Index), self-perceived hearing disability (Speech, Spatial, and Qualities of Hearing Scale), states of anxiety and depression (Hospital Anxiety and Depression Scale), and level of negative affectivity and social inhibition (Type D questionnaire).Results: Improvements of the overall cognitive functioning (p = 0.05) and the subdomain “Attention” (p = 0.02) were observed after cochlear implantation in the intervention group; their scores were compared to the corresponding scores in the control group. Significant positive effects of cochlear implantation on sound quality and self-perceived hearing outcomes were found in the intervention group. Notably, 20% fewer traits of Type D personalities were measured in the intervention group after cochlear implantation. In the control group, traits of Type D personalities increased by 13%.Conclusion: Intervention with a CI improved cognitive functioning (domain Attention in particular) in older adults with severe hearing impairment compared to that of the matched controls with hearing impairment without a CI. However, older CI users did not, in terms of cognition, bridge the performance gap with adults with normal hearing after 1 year of CI use. The fact that experienced, older CI users still present subnormal cognitive functioning may highlight the need for additional cognitive rehabilitation in the long term after implantation

    <i>ABCB1</i> (MDR1) induction defines a common resistance mechanism in paclitaxel- and olaparib-resistant ovarian cancer cells

    Get PDF
    BACKGROUND: Clinical response to chemotherapy for ovarian cancer is frequently compromised by the development of drug-resistant disease. The underlying molecular mechanisms and implications for prescription of routinely prescribed chemotherapy drugs are poorly understood. METHODS: We created novel A2780-derived ovarian cancer cell lines resistant to paclitaxel and olaparib following continuous incremental drug selection. MTT assays were used to assess chemosensitivity to paclitaxel and olaparib in drug-sensitive and drug-resistant cells±the ABCB1 inhibitors verapamil and elacridar and cross-resistance to cisplatin, carboplatin, doxorubicin, rucaparib, veliparib and AZD2461. ABCB1 expression was assessed by qRT-PCR, copy number, western blotting and immunohistochemical analysis and ABCB1 activity assessed by the Vybrant and P-glycoprotein-Glo assays. RESULTS: Paclitaxel-resistant cells were cross-resistant to olaparib, doxorubicin and rucaparib but not to veliparib or AZD2461. Resistance correlated with increased ABCB1 expression and was reversible following treatment with the ABCB1 inhibitors verapamil and elacridar. Active efflux of paclitaxel, olaparib, doxorubicin and rucaparib was confirmed in drug-resistant cells and in ABCB1-expressing bacterial membranes. CONCLUSIONS: We describe a common ABCB1-mediated mechanism of paclitaxel and olaparib resistance in ovarian cancer cells. Optimal choice of PARP inhibitor may therefore limit the progression of drug-resistant disease, while routine prescription of first-line paclitaxel may significantly limit subsequent chemotherapy options in ovarian cancer patients

    Radiation tolerance of CVD diamond detectors for pions and protons

    No full text
    The paper gives new results on the radiation tolerance of CVD diamond for irradiation with 300 MeV/ c pions and 24 GeV/ c protons. The measured charge signal spectrum is compared at several irradiation levels with the spectrum calculated by a model. Irradiation by particles causes damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model show that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal
    corecore