187 research outputs found

    Controlling Silver Nanoparticle Size and Morphology with Photostimulated Synthesis

    Full text link
    Photo-induced synthesis and control over the size and shape of colloidal silver nanoparticles is investigated in contrast to photo-stimulated aggregation of small nanoparticles into large fractal-type structures. The feasibility of light-driven nanoengineering which enables manipulation of the sizes and shapes of the isolated nanoparticles is studied by varying the amount and type of the stabilizing agent and the type of optical irradiation.Comment: 10 pages, 7 figures, 11 image

    Experimental investigation of electron cooling and stacking of lead ions in a low energy accumulation ring

    Get PDF
    This report gives the results of a programme of experimental investigations, which were carried out to test stacking of lead ions in a storage ring (the former Low Energy Antiproton Ring, LEAR) at 4.2 MeV per nucleon. The motivation was to demonstrate the feasibility of gaining the large factor in the phase-space density required for injection into the LHC. In the first part of the report, the layout of the experiments is described, the choice of the parameters of the electron cooling system used for stacking is reported and the multi-turn injection using horizontal- and longitudinal- (and in the final project also vertical-) phase space is discussed. In the second part the experimental results are presented. Factors of vital importance are the stacking efficiency, the beam life-time and the cooling time of the ions. The beam decay owing to charge exchange with the residual gas and to recombination by the capture of cooling electrons was intensively studied. Beam instabilities and space-charge effects in the ion beam turned out to be additional, although less serious, limitations of the accumulation rate. The cooling speed as a function of cooler and storage-ring properties was investigated over a wide range of parameters. Among the 'surprises' encountered are an anomalously fast recombination rate for certain ion charge states (Pb53+), a strong dependence of the cooling time on the dispersion function of the storage ring, and an intensity-dependent outgassing of equipment in the vacuum chamber. After a careful choice of parameters and antidotes, an overall factor of 120 in intensity could be gained, by multi-turn injection and stacking for 4 s. The intensity obtained (6x1086 x 10^8 ions with a length corresponding to four LHC bunches) is only a factor of two short of the LHC requirement, and the stacking time (4 s instead of 2 s foreseen for filling each LHC ring in 8 min) is another factor of two off

    Laser-stimulated Synthesis of Large Nanostructured Fractal Silver Aggregates

    Full text link
    A Laser-stimulated synthesis of large silver nanoaggregates consisting of hundreds to thousands of nanoparticles is investigated. It is shown that the morphology of the synthesized nanostructures can be controlled with light and monitored via the evolution of the colloid absorption spectra. A solution method is demonstrated that enables production of a bulk amount of metal nanoaggregates, which are of paramount importance for subwavelength concentration and dramatic enhancement of the electromagnetically-induced processes at the nanoscale.Comment: 10 pages, 8 figures, 13 reference

    Recent Results on Lead-Ion Accumulation in LEAR for the LHC

    Get PDF
    To prepare dense bunches of lead ions for the LHC it has been proposed to accumulate the 4.2 MeV/u linac beam in a storage ring with electron cooling. A series of experiments is being performed in the low-energy ring LEAR to test this technique. First results were already reported at the Beam Crystallisation Workshop in Erice in November 1995. Two more recent runs to complement these investigations were concerned with: further study of the beam lifetime; the dependence of the cooling time on optical settings of the storage ring and on neutralization of the electron beam; tests in view of multiturn injection. New results obtained in these two runs in December 1995 and in April 1996 will be discussed in this contribution

    Prospective Evaluation of Sleep Apnea as Manifestation of Heart Failure in Children

    Get PDF
    In adults with heart failure, central sleep apnea (CSA), often manifested as Cheyne–Stokes respiration, is common, and has been associated with adverse outcome. Heart failure in children is commonly caused by dilated cardiomyopathy (DCM). It is unknown whether children with heart failure secondary to DCM have CSA, and whether CSA is related to the severity of heart failure. In this prospective observational study, 37 patients (<18 year) with heart failure secondary to DCM were included. They underwent polysomnography, clinical and laboratory evaluation and echocardiographic assessment. After a median follow-up time of 2 years, eight patients underwent heart transplantation. CSA (apnea–hypopnea index [AHI] ≥1) was found in 19 % of the patients. AHI ranged from 1.2 to 4.5/h. The occurrence of CSA was not related to the severity of heart failure. Three older patients showed a breathing pattern mimicking Cheyne–Stokes respiration, two of whom required heart transplantation. CSA was found in 19 % of the children with heart failure secondary to DCM. No relation was found with the severity of heart failure. In a small subset of children with severe DCM, a pattern mimicking Cheyne–Stokes respiration was registered

    Common Avian Infection Plagued the Tyrant Dinosaurs

    Get PDF
    Background: Tyrannosaurus rex and other tyrannosaurid fossils often display multiple, smooth-edged full-thickness erosive lesions on the mandible, either unilaterally or bilaterally. The cause of these lesions in the Tyrannosaurus rex specimen FMNH PR2081 (known informally by the name 'Sue') has previously been attributed to actinomycosis, a bacterial bone infection, or bite wounds from other tyrannosaurids

    LiMeS-Lab:An Integrated Laboratory for the Development of Liquid–Metal Shield Technologies for Fusion Reactors

    Get PDF
    The liquid metal shield laboratory (LiMeS-Lab) will provide the infrastructure to develop, test, and compare liquid metal divertor designs for future fusion reactors. The main research topics of LiMeS-lab will be liquid metal interactions with the substrate material of the divertor, the continuous circulation and capillary refilling of the liquid metal during intense plasma heat loading and the retention of plasma particles in the liquid metal. To facilitate the research, four new devices are in development at the Dutch Institute for Fundamental Energy Research and the Eindhoven University of Technology: LiMeS-AM: a custom metal 3D printer based on powder bed fusion; LiMeS-Wetting, a plasma device to study the wetting of liquid metals on various substrates with different surface treatments; LiMeS-PSI, a linear plasma generator specifically adapted to operate continuous liquid metal loops. Special diagnostic protection will also be implemented to perform measurements in long duration shots without being affected by the liquid metal vapor; LiMeS-TDS, a thermal desorption spectroscopy system to characterize deuterium retention in a metal vapor environment. Each of these devices has specific challenges due to the presence and deposition of metal vapors that need to be addressed in order to function. In this paper, an overview of LiMeS-Lab will be given and the conceptual designs of the last three devices will be presented.</p

    Predicting outcome in children with dilated cardiomyopathy: the use of repeated measurements of risk factors for outcome

    Get PDF
    Aims We aimed to determine whether in children with dilated cardiomyopathy repeated measurement of known risk factors for death or heart transplantation (HTx) during disease progression can identify children at the highest risk for adverse outcome.Methods and results Of 137 children we included in a prospective cohort, 36 (26%) reached the study endpoint (SE: all-cause death or HTx), 15 (11%) died at a median of 0.09 years [inter-quartile range (IQR) 0.03-0.7] after diagnosis, and 21 (15%) underwent HTx at a median of 2.9 years [IQR 0.8-6.1] after diagnosis. Median follow-up was 2.1 years [IQR 0.8-4.3]. Twenty-three children recovered at a median of 0.6 years [IQR 0.5-1.4] after diagnosis, and 78 children had ongoing disease at the end of the study. Children who reached the SE could be distinguished from those who did not, based on the temporal evolution of four risk factors: stunting of length growth (-0.42 vs. -0.02 length Z-score per year, P 6 years at presentation (all P < 0.001) were predictive of adverse outcome. In multivariate analysis, NT-proBNP appeared the only independent predictor for adverse outcome, a two-fold higher NT-proBNP was associated with a 2.8 times higher risk of the SE (hazard ratio 2.78, 95% confidence interval 1.81-3.94, P < 0.001).Conclusions The evolution over time of NT-proBNP, LVIDd, length growth, and NYU PHFI identified a subgroup of children with dilated cardiomyopathy at high risk for adverse outcome. In this sample, with a limited number of endpoints, NT-proBNP was the strongest independent predictor for adverse outcome.Developmen

    Three new chondrosarcoma cell lines: one grade III conventional central chondrosarcoma and two dedifferentiated chondrosarcomas of bone

    Get PDF
    BackgroundChondrosarcoma is the second most common primary sarcoma of bone. High-grade conventional chondrosarcoma and dedifferentiated chondrosarcoma have a poor outcome. In pre-clinical research aiming at the identification of novel treatment targets, the need for representative cell lines and model systems is high, but availability is scarce.MethodsWe developed and characterized three cell lines, derived from conventional grade III chondrosarcoma (L835), and dedifferentiated chondrosarcoma (L2975 and L3252) of bone. Proliferation and migration were studied and we used COBRA-FISH and array-CGH for karyotyping and genotyping. Immunohistochemistry for p16 and p53 was performed as well as TP53 and IDH mutation analysis. Cells were injected into nude mice to establish their tumorigenic potential.ResultsWe show that the three cell lines have distinct migrative properties, L2975 had the highest migration rate and showed tumorigenic potential in mice. All cell lines showed chromosomal rearrangements with complex karyotypes and genotypic aberrations were conserved throughout late passaging of the cell lines. All cell lines showed loss of CDKN2A, while TP53 was wild type for exons 5–8. L835 has an IDH1 R132C mutation, L2975 an IDH2 R172W mutation and L3252 is IDH wild type.ConclusionsBased on the stable culturing properties of these cell lines and their genotypic profile resembling the original tumors, these cell lines should provide useful functional models to further characterize chondrosarcoma and to evaluate new treatment strategies

    A methodology for identifying high-need, high-cost patient personas for international comparisons.

    Get PDF
    ObjectiveTo establish a methodological approach to compare two high-need, high-cost (HNHC) patient personas internationally.Data sourcesLinked individual-level administrative data from the inpatient and outpatient sectors compiled by the International Collaborative on Costs, Outcomes, and Needs in Care (ICCONIC) across 11 countries: Australia, Canada, England, France, Germany, the Netherlands, New Zealand, Spain, Sweden, Switzerland, and the United States.Study designWe outline a methodological approach to identify HNHC patient types for international comparisons that reflect complex, priority populations defined by the National Academy of Medicine. We define two patient profiles using accessible patient-level datasets linked across different domains of care-hospital care, primary care, outpatient specialty care, post-acute rehabilitative care, long-term care, home-health care, and outpatient drugs. The personas include a frail older adult with a hip fracture with subsequent hip replacement and an older person with complex multimorbidity, including heart failure and diabetes. We demonstrate their comparability by examining the characteristics and clinical diagnoses captured across countries.Data collection/extraction methodsData collected by ICCONIC partners.Principal findingsAcross 11 countries, the identification of HNHC patient personas was feasible to examine variations in healthcare utilization, spending, and patient outcomes. The ability of countries to examine linked, individual-level data varied, with the Netherlands, Canada, and Germany able to comprehensively examine care across all seven domains, whereas other countries such as England, Switzerland, and New Zealand were more limited. All countries were able to identify a hip fracture persona and a heart failure persona. Patient characteristics were reassuringly similar across countries.ConclusionAlthough there are cross-country differences in the availability and structure of data sources, countries had the ability to effectively identify comparable HNHC personas for international study. This work serves as the methodological paper for six accompanying papers examining differences in spending, utilization, and outcomes for these personas across countries
    • …
    corecore