87 research outputs found
Use of imaging plates at near saturation for high energy density particles
Copyright 2008 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Review of Scientific Instruments, 79(10), 10E910, 2008 and may be found at http://dx.doi.org/10.1063/1.298767
Nucleophilic substitution reaction of 3-acetyl-1-methoxyindole and its application for the synthesis of novel 2-substituted methyl 2,3-dihydro-1- methyl-3-oxo-5H-pyrido-[4,3-b]indole-4-carboxylates
金沢大学大学院自然科学研究科生理活性物質科学金沢大学薬学部A simple synthetic route was established for 3-acetyl-1-methoxyindole, which was found to undergo nucleophilic substitution reactions selectively at the 2-position. Applying the reaction, novel 2-substituted methyl 2,3- dihydro-1-methyl-3-oxo-5H-pyrido[4,3-b]indole-4-carboxylates were prepared
Whole Blood Interferon-Gamma Assay for Baseline Tuberculosis Screening among Japanese Healthcare Students
BACKGROUND: The whole blood interferon-gamma assay (QuantiFERON-TB-2G; QFT) has not been fully evaluated as a baseline tuberculosis screening test in Japanese healthcare students commencing clinical contact. The aim of this study was to compare the results from the QFT with those from the tuberculin skin test (TST) in a population deemed to be at a low risk for infection with Mycobacterium tuberculosis. METHODOLOGY/PRINCIPAL FINDINGS: Healthcare students recruited at Okayama University received both the TST and the QFT to assess the level of agreement between these two tests. The interleukin-10 levels before and after exposure to M tuberculosis-specific antigens (early-secreted antigenic target 6-kDa protein [ESAT-6] and culture filtrate protein 10 [CFP-10]) were also measured. Of the 536 healthcare students, most of whom had been vaccinated with bacillus-Calmette-Guérin (BCG), 207 (56%) were enrolled in this study. The agreement between the QFT and the TST results was poor, with positive result rates of 1.4% vs. 27.5%, respectively. A multivariate analysis also revealed that the induration diameter of the TST was not affected by the interferon-gamma concentration after exposure to either of the antigens but was influenced by the number of BCG needle scars (p = 0.046). The whole blood interleukin-10 assay revealed that after antigen exposure, the median increases in interleukin-10 concentration was higher in the subgroup with the small increase in interferon-gamma concentration than in the subgroup with the large increase in interferon-gamma concentration (0.3 vs. 0 pg/mL; p = 0.004). CONCLUSIONS/SIGNIFICANCE: As a baseline screening test for low-risk Japanese healthcare students at their course entry, QFT yielded quite discordant results, compared with the TST, probably because of the low specificity of the TST results in the BCG-vaccinated population. We also found, for the first time, that the change in the interleukin-10 level after exposure to specific antigens was inversely associated with that in the interferon-gamma level in a low-risk population
Recent improvement in lung cancer screening: a comparison of the results carried out in two different time periods.
To evaluate recent improvements in lung cancer screening, we compared the results of recently conducted lung cancer screening with those of a previous screening. This study compared the survival of lung cancer patients detected by lung cancer screening conducted between 1976 and 1984 (early period) with that conducted between 1989 and 1997 (late period). Two hundred seventy-six patients with lung cancer were detected in the early period and 541 patients with lung cancer were detected in the late period. The median survival time (late : 49.8 vs. early : 27.8 months) and the 5-year survival rate (late : 47.8 vs. early : 34.8%) of the patients with lung cancer detected in the late period were significantly better than those in the early period (p = 0.0054). Among patients undergoing resection, the proportion of pathological stage I patients in the late period was significantly higher than that in the early period (late : 60.8 vs. early : 54.9%, p = 0.005). Multivariate analysis showed that the screening time period was a significant prognostic factor (hazard ratio = 0.685, 95% confidence interval : 0.563-0.832, p = 0.0002). These results were consistent with the findings of case-control studies of lung cancer screening programs in the late period recently conducted in Japan, which also showed a greater efficacy for screening than for previous case-control studies in the early period.</p
Autoinjection of electrons into a wake field using a capillary with attached cone
Copyright 2009 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Physics of Plasmas, 16(12), 123103, 2009 and may be found at http://dx.doi.org/10.1063/1.327115
Erroneous formulation of delayed-release omeprazole capsules: Alert for importing countries
Background: Poor drug quality is a matter of serious concern, especially in countries where drug regulation and law enforcement are constrained by limited resources. This study was carried out to investigate the cause of quality failure of omeprazole in Cambodia in 2010 and Myanmar in 2014. Methods: We conducted pharmacopoeial quantity, content uniformity and dissolution tests of 156 samples of omeprazole capsules collected in Cambodia in 2010 and Myanmar in 2014. High failure rates were found, especially in dissolution testing, and detailed investigation of several unacceptable samples was carried out by means of in-vitro dissolution profiling, scanning electron microscopy (SEM) and X-ray computed tomography (X-ray CT) to identify the cause of failure. Results: Dissolution profiling with and without the acid stage showed that acid caused premature omeprazole release, indicating that the enteric coating of the omeprazole granules was ineffective. SEM examination of two failed samples revealed cracked and broken granules mixed with apparently intact omeprazole granules in the capsule. X-ray CT examination indicated that some granules of failed samples completely lacked enteric coating, and others had incomplete and non-uniform enteric coating or malformation. Conclusions: Omeprazole capsules collected in Myanmar and Cambodia showed high failure rates in pharmacopoeial tests, especially dissolution tests. Some samples were found to have ineffective or absent enteric coating of the granules, resulting in premature dissolution and degradation in acidic conditions. This is a potentially serious public health issue that needs to be addressed by regulatory authorities in Cambodia and Myanmar, possibly through a collaborative initiative with manufacturers. © 2017 The Author(s)
A cross-sectional investigation of the quality of selected medicines in Cambodia in 2010.
Access to good-quality medicines in many countries is largely hindered by the rampant circulation of spurious/falsely labeled/falsified/counterfeit (SFFC) and substandard medicines. In 2006, the Ministry of Health of Cambodia, in collaboration with Kanazawa University, Japan, initiated a project to combat SFFC medicines. To assess the quality of medicines and prevalence of SFFC medicines among selected products, a cross-sectional survey was carried out in Cambodia. Cefixime, omeprazole, co-trimoxazole, clarithromycin, and sildenafil were selected as candidate medicines. These medicines were purchased from private community drug outlets in the capital, Phnom Penh, and Svay Rieng and Kandal provinces through a stratified random sampling scheme in July 2010. In total, 325 medicine samples were collected from 111 drug outlets. Non-licensed outlets were more commonly encountered in rural than in urban areas (p < 0.01). Of all the samples, 93.5% were registered and 80% were foreign products. Samples without registration numbers were found more frequently among foreign-manufactured products than in domestic ones (p < 0.01). According to pharmacopeial analytical results, 14.5%, 4.6%, and 24.6% of the samples were unacceptable in quantity, content uniformity, and dissolution test, respectively. All the ultimately unacceptable samples in the content uniformity tests were of foreign origin. Following authenticity investigations conducted with the respective manufacturers and medicine regulatory authorities, an unregistered product of cefixime collected from a pharmacy was confirmed as an SFFC medicine. However, the sample was acceptable in quantity, content uniformity, and dissolution test. The results of this survey indicate that medicine counterfeiting is not limited to essential medicines in Cambodia: newer-generation medicines are also targeted. Concerted efforts by both domestic and foreign manufacturers, wholesalers, retailers, and regulatory authorities should help improve the quality of medicines
Torus Constraints in ANEPD-CXO245: A Compton-thick AGN with Double-peaked Narrow Lines
We report on the torus constraints of the Compton-thick active galactic nucleus (AGN) with double-peaked optical narrow-line region emission lines, ANEPD-CXO245, at z = 0.449 in the AKARI NEP Deep Field. The unique infrared data on this field, including those from the nine-band photometry over 2–24 μm with the AKARI Infrared Camera, and the X-ray spectrum from Chandra allow us to constrain torus parameters such as the torus optical depth, X-ray absorbing column, torus angular width (σ), and viewing angle (i). We analyze the X-ray spectrum as well as the UV–optical–infrared spectral energy distribution (UOI-SED) with clumpy torus models in X-ray (XCLUMPY) and infrared (CLUMPY), respectively. From our current data, the constraints on σ–i from both X-rays and UOI show that the line of sight crosses the torus as expected for a type 2 AGN. We obtain a small X-ray scattering fraction (NH from the X-ray spectrum, we find that the gas-to-dust ratio is <4 times larger than the Galactic value
- …