225 research outputs found

    Incoherent single pion electroproduction on the deuteron with polarization effects

    Get PDF
    Incoherent pion electroproduction on the deuteron is studied from threshold up to the second resonance region with special emphasis on the influence of final state interaction, in particular on polarization observables. The elementary γNπN\gamma N\to\pi N amplitude is taken from the MAID-2003 model. Final state interaction is included by considering complete rescattering in the final NNNN and πN\pi N subsystems. Their influence on the structure functions governing the semi-exclusive differential cross section, where besides the scattered electron only the produced pion is detected, is investigated in detail. For charged pion-production the effect of NNNN-rescattering is moderate whereas πN\pi N-rescattering is almost negligible, except very close to threshold. NNNN-rescattering appears much stronger in neutral pion production for which the primary mechanism is the elimination of a significant spurious coherent contribution in the impulse approximation. Sizeable effects are also found in some of the polarization structure functions for beam and/or target polarizations.Comment: 20 pages including 14 figure

    Assessment of natural radionuclides and heavy metal concentrations in marine sediments in view of tourism activities in Hurghada city, northern Red Sea, Egypt

    Get PDF
    The specific activity of 40K, 232Th and 226Ra in marine sediment samples collected from National Institute of Oceanography and Fisheries (NIOF) and Safier Hotel area in Hurghada city (the most important regions in Egypt), were measured by gamma ray spectrometry using NaI(Tl) detector. The values of specific activity varied from 7 ± 1 Bq kg-1 to 53 ± 4 Bq kg-1, 6 ± 1 Bq kg-1 to 32 ± 6 Bq kg-1, and from 167 ± 11 Bq kg-1 to 1120 ± 63 Bq kg-1 for 226Ra, 232Th and 40K, respectively. The heavy metals have been measured and analysed by atomic absorption spectrometer. The major range values of heavy metals concentrations in marine sediment samples were: Cu (10.5-78.0 μg g-1), Zn (21-150 μg g-1), Pb (30-53 μg g-1), Cd (2.50-4.00 μg g-1), Fe (5100-13150 μg g-1), Mn (118-298 μg g-1), Ni (17-36 μg g-1) and Co (16-18 μg g-1). The total organic matter (TOC) and carbonates (CaCo3) distribution have been measured at some locations. Also, the frequency distribution and the value of (232Th/226Ra), (232Th/40K) and (226Ra/40K) ratio for all measured samples were determined. Additionally, evaluations have been made of the radiological hazards and the results are diagrammed by Surfer program in maps. © Penerbit Universiti Sains Malaysia, 2019

    Three-dimensional transvaginal ultrasound: clinical implementation in assessing uterine cavity

    Get PDF
    Background: Three-dimensional transvaginal ultrasonography (3D TVS) represents a new technique of imaging and provides a unique diagnostic tool for non-invasive examination of the uterine morphology and diagnosis of congenital uterine anomalies. In this study the clinical value of 3D TVS in diagnosis of uterine cavity abnormalities were evaluated.Methods: A prospective of diagnostic accuracy study included 226 patients with various clinical presentations; infertility, recurrent pregnancy loss, menstrual disorders and post-menopausal bleeding with suspected uterine cavity lesions or abnormality on two-dimensional (2D) TVS or hysterosalpingography (HSG). After taking consent, all patients were subjected to history taking, clinical examination, 3D TVS evaluation, magnetic resonance imaging (MRI) and finally endoscopic examination.Results: The 3D has 98% accuracy in infertile women in comparison to 87% for MRI. While with recurrent pregnancy loss, Concordance was 96% correct for 3D and 78% for MRI. The women with abnormal uterine bleeding, the accuracy of 3D was 100%, while with MRI was 74%. The sensitivity of 3D TVS was 97.8% and 100% specificity, positive and negative predictive value. While the sensitivity, specificity, positive and negative predictive values for MRI were 89.3%, 64%, 70.4% and 86.3% respectively.Conclusions: 3D TVS appears to be extremely accurate, less expensive and a rapid examination for the diagnosis and classification of uterine anomalies, more than MRI. Thus it may become the only mandatory step in the assessment of the uterine cavity

    Theoretical Study of the Circuit Architecture of the Basic CFOA and Testing Techniques

    Get PDF
    This paper examines the closed-loop characteristics of the basic CFOA, and in particular, the dynamic response. Additionally, it also examines the design and advantages of the CFOA regarding its ability to provide a significantly constant closed-loop bandwidth for closed-loop voltage gain. Secondly, the almost limitless slew–rate provided by the class AB input stage that makes it superior to the VOA counterpart. Additionally; this paper also concerns the definitions and measurements of the terminal parameters of the CFOA, regarded as a ‘black box’. It does not deal with the way that these parameters are related to the properties of the active passive and active components of a particular circuit configuration. Simulation is used in terminal parameter determination: this brings with it the facility of using test conditions that would not normally prevail in a laboratory test on silicon implementations of the CFOAs. Thus, we can apply 1mA and 1mV test signals from, respectively, infinite and zero source impedances that range in frequency from d.c to some tens of GHz. Also, we assume the existence of resistors with identical Ohmic value and very high value ideal capacitors. Where appropriate, practical test methods are referred to physical laboratory prototypes

    A novel current-feedback op-amp exploiting bootstrapping techniques

    Get PDF
    The operation of the conventional current feedback operational amplifier (CFOA) is reviewed and its performance parameters used as benchmarks in the development of a new input stage architecture that provides a common-mode rejection ratio (CMRR) improvement of some 45 dB and offset voltage less than 10 mV

    Improved designs for current feedback op-amps

    Get PDF
    The performance of the current feedback op-amps (CFOAs) is very much determined by the input stage of CFOAs, including common-mode rejection ratio (CMRR). Two new CFOAs topologies are presented in this article: one topology uses a cascoding technique, and the second one uses a bootstrapping technique, both of which provide a much better CMRR and lower DC offset voltage than the conventional CFOAs. Moreover, the new CFOAs design exhibits an extended high frequency bandwidth, with a gain accuracy improvement. Applications requiring constant bandwidth with variable (closed loop) gain will benefit from the proposed topologies

    Chemistry and biological activities of the marine sponges of the genera mycale (Arenochalina), Biemna and Clathria

    Get PDF
    Over the past seven decades, particularly since the discovery of the first marine-derived nucleosides, spongothymidine and spongouridine, from the Caribbean sponge Cryptotethya crypta in the early 1950s, marine natural products have emerged as unique, renewable and yet under-investigated pools for discovery of new drug leads with distinct structural features, and myriad interesting biological activities. Marine sponges are the most primitive and simplest multicellular animals, with approximately 8900 known described species, although more than 15,000 species are thought to exist worldwide today. These marine organisms potentially represent the richest pipeline for novel drug leads. Mycale (Arenochalina) and Clathria are recognized marine sponge genera belonging to the order Poecilosclerida, whereas Biemna was more recently reclassified, based on molecular genetics, as a new order Biemnida. Together, these sponge genera contribute to the production of physiologically active molecular entities with diverse structural features and a wide range of medicinal and therapeutic potentialities. In this review, we provide a comprehensive insight and up-to-date literature survey over the period of 1976–2018, focusing on the chemistry of the isolated compounds from members of these three genera, as well as their biological and pharmacological activities, whenever available. © 2018 by the authors.Acknowledgments: This work was supported by the mission sector of the Ministry of High Education of the Arab Republic of Egypt (Egyptian cultural bureau in Paris and Athens); Amr El-Demerdash’s, and Mohamed Tammam’s joint supervision were fully funded and supported

    Wide-Bandwidth CFOA with High CMRR Performance

    Get PDF
    ​In this paper the authors analyze the conventional current-feedback operational amplifier (CFOA) in terms of common-mode-rejection ratio (CMRR) performance, and having identified the mechanism primarily responsible for the CMRR, they propose two new architecture CFOAs. These new CFOAs are further developed, and modified to provide improved bandwidth, AC gain accuracy and high CMRR performance. The key features of the two proposed new CFOAs are the designs of the internal voltage followers which have two separate biasing currents with a similar dynamic architecture to that of the conventional CFOA. The magnitude of one bias current determines the value of the maximum CMRR, and the second can be used to maximize bandwidth

    Estimate the absolute efficiency by MATLAB for the NaI (Tl) detector using IAEA-314

    Full text link
    This works amid to calculating the absolute efficiency at any interesting γ-energy in the energy range between 10 and 1764 keV. by using fit function which has been developed to calculate theoretically the absolute γ-ray detection efficiencies of a cylindrical NaI(Tl) crystal. Efficiency of the NaI(Tl) calculator is a program built in MATLAB by the author of this paper to make it easier to calculate the efficiency of standard source. The absolute γ-ray detection efficiencies have been calculated for detectors 3? x 3? inches NaI(Tl) crystal. The absolute efficiency of the NaI (Tl) detector was calculated using standard sources (IAEA-314) which have known activity of 226Ra (732 Bqkg-1) and 232Th (17.8 ppm). In this calculation, experimental and theoretical efficiencies have been calculated. The uncertainties of efficiency calibration have been calculated also for quality control. Measurements were performed with calibrated point source. Gamma-ray energies under consideration were 0.356, 0.662, 1.17 and 1.33 MeV. Efficiency function was obtained by applying Weibull Model equation to the experimental efficiency data which give Best agreement between experimental and theoretical absolute detection efficiencies of 3×3-inch detector for gamma energy. © 2019 Author(s)
    corecore