6,809 research outputs found

    Directional Degradation of Spectralon Diffuser Under Ionizing Radiation for Calibration of Space-Based Sensors

    Get PDF
    Assessment of the effect of Vacuum Ultra Violet (VUV) irradiation on the Bidirectional Reflectance Distribution Function (BRDF) of Spectralon is presented in this paper. The sample was a 99% white Spectralon calibration standard irradiated with VUV source positioned at 60o off the irradiation direction for a total of 20 hours. The BRDF before and after VUV irradiation was measured and compared at number of wavelengths in the UV, VIS and IR. Non-isotropic directional degradation of Spectralon diffuser under ionizing radiation was detected at different BRDF measurement geometries primarily at UV spectral range. The 8o directional/hemispherical reflectance of the same sample was also measured and compared from 200nm to 2500nm. Index Terms BRDF, Reflectance, Multiangular, Spectralon, Remote Sensin

    Polar Mesospheric Clouds (PMCs) Observed by the Ozone Monitoring Instrument (OMI) on Aura

    Get PDF
    Backscattered ultraviolet (BUV) instruments designed for measuring stratospheric ozone profiles have proven to be robust tools for observing polar mesospheric clouds (PMCs). These measurements are available for more than 30 years, and have been used to demonstrate the existence of long-term variations in PMC occurrence frequency and brightness. The Ozone Monitoring Instrument (OMI) on the EOS Aura satellite provides new and improved capabilities for PMC characterization. OMI uses smaller pixels than previous BUV instruments, which increases its ability to identify PMCs and discern more spatial structure, and its wide cross-track viewing swath provides full polar coverage up to 90 latitude every day in both hemispheres. This cross-track coverage allows the evolution of PMC regions to be followed over several consecutive orbits. Localized PMC variations determined from OMI measurements are consistent with coincident SBUV/2 measurements. Nine seasons of PMC observations from OMI are now available, and clearly demonstrate the advantages of these measurements for PMC analysis

    Effects of Orthogonal Rotating Electric Fields on Electrospinning Process

    Full text link
    Electrospinning is a nanotechnology process whereby an external electric field is used to accelerate and stretch a charged polymer jet, so as to produce fibers with nanoscale diameters. In quest of a further reduction in the cross section of electrified jets hence of a better control on the morphology of the resulting electrospun fibers, we explore the effects of an external rotating electric field orthogonal to the jet direction. Through extensive particle simulations, it is shown that by a proper tuning of the electric field amplitude and frequency, a reduction of up to a 30%30 \% in the aforementioned radius can be obtained, thereby opening new perspectives in the design of future ultra-thin electrospun fibres. Applications can be envisaged in the fields of nanophotonic components as well as for designing new and improved filtration materials.Comment: 22 pages, 8 figure

    Influence of surgical resection no plasma Endoglin (CD105) level in non-small cell lung cancer patients

    No full text
    Background and Aim: Endoglin is a proliferation-associated antigen on endothelial cells and essential for angiogenesis. Soluble endoglin (s‑endoglin), formed by proteolytic cleavage of ectodomain of membrane receptor could be an indicator of tumor‑activated endothelium. The aim of present study was to analyze changes of s‑endoglin level in plasma of lung cancer patients following surgical resection and to estimate the correlation of s‑endoglin with other soluble receptors, sTie2 and sVEGF R1. Patients and Methods: The study group consisted of 37 patients with stage I of non-small cell lung cancer. Plasma concentrations of s‑endoglin, sTie2 and sVEGF R1 were evaluated by ELISA, three times: before surgical resection and on postoperative day 7 and 30. Results: The median of s‑endoglin concentration decreased significantly on postoperative day 7 when compared with preoperative level and next increased on 30th day and it was comparable with that before surgery. s-Endoglin correlated with another soluble receptors, with sTie2 both before surgery (r=0.44) and on postoperative day 7 (r=0.52) and on 30th day (r=0.58), with sVEGF R1 — only on postoperative day 7 (r=0.75). Conclusion: The increased level of serum endoglin in lung cancer patients compared to controls and its changes after surgical treatment suggest potential application of soluble form of endoglin as potential tumor marker

    Power cycling analysis of enameled aluminium winding wires connections pprepared with the use of SHARK-Al® type connectors

    Get PDF
    The article presents the research results of current cyclic thermal tests performed on enamelled aluminium wires connections, made with the use of a new type of Shark-Al quick-connectors. In particular, the main purpose of the conducted research was to analyse the effect of cyclic heating on the contact resistance change during the tests which allows to test the stability of the connections in simulated working conditions under current flow. Tests included a total of 300 thermal cycles, of which the first 200 were carried out to the 65 °C temperature measured in the connector at above the ambient temperature, and then additional 100 cycles were performed for the temperature of the connector at 140 °C (tolerance +5 °C). During the tests, the resistance of samples was monitored, which allowed to verify the correctness of performed connections

    Research on mechanical and electrical properties of enamel winding wires connections made with the use of SHARK-Al® technology

    Get PDF
    The results of the research that have been presented in this article include the analysis of basic exploitational properties of connections made with the use of new family of Shark-Al connectors, which are the first in the industry strictly dedicated for connecting the enamelled aluminium wires. In particular, the test results include the analysis of the contact resistance and tensile strength of connections prepared with the various types of connectors and various configurations of used enamelled wires. Results of this work enabled to verify the correctness of performed connecting process and also allowed to verify the connectors design
    corecore