3,430 research outputs found
Tunable subpicosecond electron bunch train generation using a transverse-to-longitudinal phase space exchange technique
We report on the experimental generation of a train of subpicosecond electron
bunches. The bunch train generation is accomplished using a beamline capable of
exchanging the coordinates between the horizontal and longitudinal degrees of
freedom. An initial beam consisting of a set of horizontally-separated beamlets
is converted into a train of bunches temporally separated with tunable bunch
duration and separation. The experiment reported in this Letter unambiguously
demonstrates the conversion process and its versatility.Comment: 4 pages, 5 figures, 1 table; accepted for publication in PR
Upgrades of beam diagnostics in support of emittance-exchange experiments at the Fermilab A0 photoinjector
The possibility of using electron beam phase space manipulations to support a
free-electron laser accelerator design optimization has motivated our research.
An on-going program demonstrating the exchange of transverse horizontal and
longitudinal emittances at the Fermilab A0 photoinjector has benefited recently
from the upgrade of several of the key diagnostics stations. Accurate
measurements of these properties upstream and downstream of the exchanger
beamline are needed. Improvements in the screen resolution term and reduced
impact of the optical system's depth-of-focus by using YAG:Ce single crystals
normal to the beam direction will be described. The requirement to measure
small energy spreads (<10 keV) in the spectrometer and the exchange process
which resulted in bunch lengths less than 500 fs led to other diagnostics
performance adjustments and upgrades as well. A longitudinal to transverse
exchange example is also reported.Comment: 16 p
Development of diamond tracking detectors for high luminosity experiments at the LHC: addendum
Micro-strip sensors based on CVD Diamond
In this article we present the performance of recent chemical vapour deposition (CVD) diamond micro-strip sensors in beam tests. In addition we present the first comparison of a CVD diamond micro-strip sensor before and after proton irradiation
Performance of irradiated CVD diamond micro-strip sensors
CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a -source and the performance before and after intense () proton- and pion-irradiations. We find that low dose irradiations increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiations with protons () lowers the signal-to-noise ratio slightly. Intense irradiation with pions () lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations
First observation of the exchange of transverse and longitudinal emittances
An experimental program to demonstrate a novel phase space manipulation in
which the horizontal and longitudinal emittances of a particle beam are
exchanged has been completed at the Fermilab A0 Photoinjector. A new beamline,
consisting of a TM110 deflecting mode cavity flanked by two horizontally
dispersive doglegs has been installed. We report on the first direct
observation of transverse and longitudinal emittance exchange
Tako-tsubo cardiomyopathy after administration of ergometrine following elective caesarean delivery: a case report
<p>Abstract</p> <p>Introduction</p> <p>Tako-tsubo cardiomyopathy (stress-induced cardiomyopathy or transient left ventricular ballooning) is characterized by clinical suspicion of an acute myocardial infarction with transient apical or midventricular dyskinesia of the left ventricle without significant coronary stenosis on angiography. The etiology of this disease remains obscure. One of the possible causes is myocardial ischemia induced by coronary vasospasm due to sympathetic activation. It has been hypothesized that the application of ergometrine could induce tako-tsubo cardiomyopathy.</p> <p>Case presentation</p> <p>We report the case of a 28-year-old Turkish woman who developed tako-tsubo cardiomyopathy after administration of ergometrine for release of placenta and prevention of bleeding during the post-partum phase in the course of an elective caesarean delivery. Tako-tsubo cardiomyopathy was diagnosed by echocardiography and urgent cardiac magnetic resonance imaging. A coronary angiography was not performed because of the absence of myocardial necrosis or ischemia and signs of myocarditis on cardiac magnetic resonance imaging.</p> <p>Conclusion</p> <p>This life-threatening disease should be excluded in the differential diagnosis by comparing the symptoms with those of typical heart failure, particularly after use of ergometrine.</p
Recommended from our members
A copper 3.9 GHz TM110 cavity for emittance exchange
An experiment is being developed at the FNAL Photoinjector Lab to demonstrate the exchange of longitudinal emittance with a transverse horizontal emittance. The longitudinal electric field of a TM{sub 110} cavity vanishes on axis and increases linearly with transverse displacement. This 'shearing' electric field is pivotal to the exchange. The design of this TM{sub 110} cavity is a variant of the Fermilab 3.9 GHz superconducting deflecting mode cavity; however, the cavity was constructed of OFHC copper. The authors report on the construction, field flatness, polarization and high power testing of a TM{sub 110} cavity
- …
