5,049 research outputs found
Development of a public audiology service in Southern Malawi: profile of patients across two years
Objective
To describe the profile of patients attending the Queen Elizabeth Central Hospital (QECH) audiology clinic in Malawi, over a two-year period (2016–2017).
Design
A retrospective patient record review.
Study sample
There were 2299 patients assessed at the QECH audiology department between January 2016 and December 2017. Adult patients’ ages ranged from 18 to 94 years (M = 45.8, SD = 19.22). The mean age of children included in this study was 7.7 years (SD= 5.21). Overall, 45.4% of patients were female.
Results
Of the 61.6% of adults and 41.7% of children found to have some degree of hearing loss, 28.3% and 15.4% were fitted with hearing aids, respectively. The number of patients seen in 2017 (n = 1385) was 34% higher than that of 2016 (n = 914).
Conclusion
This study found that demand for hearing services is increasing in this public sector Malawian audiology department but uptake of hearing aids for those in need is low. Future evaluation of service provision and treatment outcomes is needed. Results from this study can be used to inform the development of future audiology clinics in low resource settings
Total column CO_2 measurements at Darwin, Australia – site description and calibration against in situ aircraft profiles
An automated Fourier Transform Spectroscopic (FTS) solar observatory was established in Darwin, Australia in August 2005. The laboratory is part of the Total Carbon Column Observing Network, and measures atmospheric column abundances of CO_2 and O_2 and other gases. Measured CO_2 columns were calibrated against integrated aircraft profiles obtained during the TWP-ICE campaign in January–February 2006, and show good agreement with calibrations for a similar instrument in Park Falls, Wisconsin. A clear-sky low airmass relative precision of 0.1% is demonstrated in the CO2 and O2 retrieved column-averaged volume mixing ratios. The 1% negative bias in the FTS X_(CO_2) relative to the World Meteorological Organization (WMO) calibrated in situ scale is within the uncertainties of the NIR spectroscopy and analysis
The Scuppernong River Project, Volume 1: Explorations of Tyrrell County Maritime History
PAST Foundation, UNC Coastal Studies Institute, East Carolina Universit
Adapting Multichip Module Foundries for MEMS Packaging
Abstract Methods of packaging micro-electro-mechanical systems (MEM
Classification of Light-Induced Desorption of Alkali Atoms in Glass Cells Used in Atomic Physics Experiments
We attempt to provide physical interpretations of light-induced desorption
phenomena that have recently been observed for alkali atoms on glass surfaces
of alkali vapor cells used in atomic physics experiments. We find that the
observed desorption phenomena are closely related to recent studies in surface
science, and can probably be understood in the context of these results. If
classified in terms of the photon-energy dependence, the coverage and the
bonding state of the alkali adsorbates, the phenomena fall into two categories:
It appears very likely that the neutralization of isolated ionic adsorbates by
photo-excited electron transfer from the substrate is the origin of the
desorption induced by ultraviolet light in ultrahigh vacuum cells. The
desorption observed in low temperature cells, on the other hand, which is
resonantly dependent on photon energy in the visible light range, is quite
similar to light-induced desorption stimulated by localized electronic
excitation on metallic aggregates. More detailed studies of light-induced
desorption events from surfaces well characterized with respect to alkali
coverage-dependent ionicity and aggregate morphology appear highly desirable
for the development of more efficient alkali atom sources suitable to improve a
variety of atomic physics experiments.Comment: 6 pages, 1 figure; minor corrections made, published in e-Journal of
Surface Science and Nanotechnology at
http://www.jstage.jst.go.jp/article/ejssnt/4/0/4_63/_articl
Roaring to Softly Whispering: X-Ray Emission after ∼3.7 yr at the Location of the Transient AT2018cow and Implications for Accretion-powered Scenarios
We present the first deep X-ray observations of luminous fast blue optical transient (LFBOT) AT 2018cow at ∼3.7 yr since discovery, together with the reanalysis of the observation at δt ∼ 220 days. X-ray emission is significantly detected at a location consistent with AT 2018cow. The very soft X-ray spectrum and sustained luminosity are distinct from the spectral and temporal behavior of the LFBOT in the first ∼100 days and would possibly signal the emergence of a new emission component, although a robust association with AT 2018cow can only be claimed at δt ∼ 220 days, while at δt ∼ 1350 days contamination of the host galaxy cannot be excluded. We interpret these findings in the context of the late-time panchromatic emission from AT 2018cow, which includes the detection of persistent, slowly fading UV emission with νLν ≈ 1039 erg s−1. Similar to previous works (and in analogy with arguments for ultraluminous X-ray sources), these late-time observations are consistent with thin disks around intermediate-mass black holes (with M• ≈ 103–104M☉) accreting at sub-Eddington rates. However, differently from previous studies, we find that smaller-mass black holes with M• ≈ 10–100 M☉ accreting at ≳the Eddington rate cannot be ruled out and provide a natural explanation for the inferred compact size (Rout ≈ 40 R☉) of the accretion disk years after the optical flare. Most importantly, irrespective of the accretor mass, our study lends support to the hypothesis that LFBOTs are accretion-powered phenomena and that, specifically, LFBOTs constitute electromagnetic manifestations of super-Eddington accreting systems that evolve to ≲Eddington over a ≈100-day timescale
Evaluation of the LEP Centre-of-Mass Energy Above the W-Pair Production Threshold
Knowledge of the centre-of-mass energy at LEP2 is of primary importance to
set the absolute energy scale for the measurement of the W-boson mass. The beam
energy above 80 GeV is derived from continuous measurements of the magnetic
bending field by 16 NMR probes situated in a number of the LEP dipoles. The
relationship between the fields measured by the probes and the beam energy is
calibrated against precise measurements of the average beam energy between 41
and 55 GeV made using the resonant depolarisation technique. The linearity of
the relationship is tested by comparing the fields measured by the probes with
the total bending field measured by a flux loop. This test results in the
largest contribution to the systematic uncertainty. Several further corrections
are applied to derive the the centre-of-mass energies at each interaction
point. In addition the centre-of-mass energy spread is evaluated. The beam
energy has been determined with a precision of 25 MeV for the data taken in
1997, corresponding to a relative precision of 2.7x10^{-4}. This is small in
comparison to the present uncertainty on the W mass measurement at LEP.
However, the ultimate statistical precision on the W mass with the full LEP2
data sample should be around 25 MeV, and a smaller uncertainty on the beam
energy is desirable. Prospects for improvements are outlined.Comment: 24 pages, 10 figures, Latex, epsfig; replaced by version accepted by
European Physical Journal
Cascade and anti-Cascade Polarization Measurements at 800 GeV/c
The polarization of neutral Cascade and anti-Cascade hyperons produced by 800
GeV/c protons on a BeO target at a fixed targeting angle of 4.8 mrad is
measured by the KTeV experiment at Fermilab. Our result of 9.7% for the neutral
Cascade polarization shows no significant energy dependence when compared to a
result obtained at 400 GeV/c production energy and at twice our targeting
angle. The polarization of the neutral anti-Cascade is measured for the first
time and found to be consistent with zero. We also examine the dependence of
polarization on transverse production momentum.Comment: 4 page PR
Primary vs. Secondary Antibody Deficiency: Clinical Features and Infection Outcomes of Immunoglobulin Replacement
<div><p>Secondary antibody deficiency can occur as a result of haematological malignancies or certain medications, but not much is known about the clinical and immunological features of this group of patients as a whole. Here we describe a cohort of 167 patients with primary or secondary antibody deficiencies on immunoglobulin (Ig)-replacement treatment. The demographics, causes of immunodeficiency, diagnostic delay, clinical and laboratory features, and infection frequency were analysed retrospectively. Chemotherapy for B cell lymphoma and the use of Rituximab, corticosteroids or immunosuppressive medications were the most common causes of secondary antibody deficiency in this cohort. There was no difference in diagnostic delay or bronchiectasis between primary and secondary antibody deficiency patients, and both groups experienced disorders associated with immune dysregulation. Secondary antibody deficiency patients had similar baseline levels of serum IgG, but higher IgM and IgA, and a higher frequency of switched memory B cells than primary antibody deficiency patients. Serious and non-serious infections before and after Ig-replacement were also compared in both groups. Although secondary antibody deficiency patients had more serious infections before initiation of Ig-replacement, treatment resulted in a significant reduction of serious and non-serious infections in both primary and secondary antibody deficiency patients. Patients with secondary antibody deficiency experience similar delays in diagnosis as primary antibody deficiency patients and can also benefit from immunoglobulin-replacement treatment.</p></div
First Observation of the decay KL -> pi0 e e gamma
We report on the first observation of the decay KL -> pi0 ee gamma by the
KTeV E799 experiment at Fermilab. Based upon a sample of 48 events with an
estimated background of 3.6 +/- 1.1 events, we measure the KL -> pi0 ee gamma
branching ratio to be (2.34 +/- 0.35 +/- 0.13)x10^{-8}. Our data agree with
recent O(p^6) calculations in chiral perturbation theory that include
contributions from vector meson exchange through the parameter a_V. A fit was
made to the KL -> pi0 ee gamma data for a_V with the result -0.67 +/- 0.21 +/-
0.12, which is consistent with previous results from KTeV.Comment: Submitted to Physical Review Letters, 5 pages, 5 figure
- …