7,429 research outputs found
Smart helmet: wearable multichannel ECG & EEG
Modern wearable technologies have enabled continuous recording of vital signs, however, for activities such as cycling, motor-racing, or military engagement, a helmet with embedded sensors would provide maximum convenience and the opportunity to monitor simultaneously both the vital signs and the electroencephalogram (EEG). To this end, we investigate the feasibility of recording the electrocardiogram (ECG), respiration, and EEG from face-lead locations, by embedding multiple electrodes within a standard helmet. The electrode positions are at the lower jaw, mastoids, and forehead, while for validation purposes a respiration belt around the thorax and a reference ECG from the chest serve as ground truth to assess the performance. The within-helmet EEG is verified by exposing the subjects to periodic visual and auditory stimuli and screening the recordings for the steady-state evoked potentials in response to these stimuli. Cycling and walking are chosen as real-world activities to illustrate how to deal with the so-induced irregular motion artifacts, which contaminate the recordings. We also propose a multivariate R-peak detection algorithm suitable for such noisy environments. Recordings in real-world scenarios support a proof of concept of the feasibility of recording vital signs and EEG from the proposed smart helmet
Performance of AAOmega: the AAT multi-purpose fibre-fed spectrograph
AAOmega is the new spectrograph for the 2dF fibre-positioning system on the
Anglo-Australian Telescope. It is a bench-mounted, double-beamed design, using
volume phase holographic (VPH) gratings and articulating cameras. It is fed by
392 fibres from either of the two 2dF field plates, or by the 512 fibre SPIRAL
integral field unit (IFU) at Cassegrain focus. Wavelength coverage is 370 to
950nm and spectral resolution 1,000-8,000 in multi-Object mode, or 1,500-10,000
in IFU mode. Multi-object mode was commissioned in January 2006 and the IFU
system will be commissioned in June 2006.
The spectrograph is located off the telescope in a thermally isolated room
and the 2dF fibres have been replaced by new 38m broadband fibres. Despite the
increased fibre length, we have achieved a large increase in throughput by use
of VPH gratings, more efficient coatings and new detectors - amounting to a
factor of at least 2 in the red. The number of spectral resolution elements and
the maximum resolution are both more than doubled, and the stability is an
order of magnitude better.
The spectrograph comprises: an f/3.15 Schmidt collimator, incorporating a
dichroic beam-splitter; interchangeable VPH gratings; and articulating red and
blue f/1.3 Schmidt cameras. Pupil size is 190mm, determined by the competing
demands of cost, obstruction losses, and maximum resolution. A full suite of
VPH gratings has been provided to cover resolutions 1,000 to 7,500, and up to
10,000 at particular wavelengths.Comment: 13 pages, 4 figures; presented at SPIE, Astronomical Telescopes and
Instrumentation, 24 - 31 May 2006, Orlando, Florida US
An experimental study of the rearrangements of valence protons and neutrons amongst single-particle orbits during double {\beta} decay in 100Mo
The rearrangements of protons and neutrons amongst the valence
single-particle orbitals during double {\beta} decay of 100Mo have been
determined by measuring cross sections in (d,p), (p,d), (3He,{\alpha}) and
(3He,d) reactions on 98,100Mo and 100,102Ru targets. The deduced nucleon
occupancies reveal significant discrepancies when compared with theoretical
calculations; the same calculations have previously been used to determine the
nuclear matrix element associated with the decay probability of double {\beta}
decay of the 100Mo system.Comment: 18 pages, 13 figures, 37 pages of supplemental informatio
Neuronal synchrony: peculiarity and generality
Synchronization in neuronal systems is a new and intriguing application of dynamical systems theory. Why are neuronal systems different as a subject for synchronization? (1) Neurons in themselves are multidimensional nonlinear systems that are able to exhibit a wide variety of different activity patterns. Their “dynamical repertoire” includes regular or chaotic spiking, regular or chaotic bursting, multistability, and complex transient regimes. (2) Usually, neuronal oscillations are the result of the cooperative activity of many synaptically connected neurons (a neuronal circuit). Thus, it is necessary to consider synchronization between different neuronal circuits as well. (3) The synapses that implement the coupling between neurons are also dynamical elements and their intrinsic dynamics influences the process of synchronization or entrainment significantly. In this review we will focus on four new problems: (i) the synchronization in minimal neuronal networks with plastic synapses (synchronization with activity dependent coupling), (ii) synchronization of bursts that are generated by a group of nonsymmetrically coupled inhibitory neurons (heteroclinic synchronization), (iii) the coordination of activities of two coupled neuronal networks (partial synchronization of small composite structures), and (iv) coarse grained synchronization in larger systems (synchronization on a mesoscopic scale
Low Temperature Opacities
Previous computations of low temperature Rosseland and Planck mean opacities
from Alexander & Ferguson (1994) are updated and expanded. The new computations
include a more complete equation of state with more grain species and updated
optical constants. Grains are now explicitly included in thermal equilibrium in
the equation of state calculation, which allows for a much wider range of grain
compositions to be accurately included than was previously the case. The
inclusion of high temperature condensates such as AlO and CaTiO
significantly affects the total opacity over a narrow range of temperatures
before the appearance of the first silicate grains.
The new opacity tables are tabulated for temperatures ranging from 30000 K to
500 K with gas densities from 10 g cm to 10 g cm.
Comparisons with previous Rosseland mean opacity calculations are discussed. At
high temperatures, the agreement with OPAL and Opacity Project is quite good.
Comparisons at lower temperatures are more divergent as a result of differences
in molecular and grain physics included in different calculations. The
computation of Planck mean opacities performed with the opacity sampling method
are shown to require a very large number of opacity sampling wavelength points;
previously published results obtained with fewer wavelength points are shown to
be significantly in error. Methods for requesting or obtaining the new tables
are provided.Comment: 39 pages with 12 figures. To be published in ApJ, April 200
Recommended from our members
Dynamic Analysis of Double Wishbone Front Suspension Systems for Sport Motorcycles
In this paper, two alternative front suspension systems and their influence on motorcycle dynamics are investigated. Based on an existing motorcycle mathematical model, the front end is modified to accommodate both Girder and Hossack suspension systems. Both of them have in common a double wishbone design that varies the front end geometry on certain manoeuvrings and, consequently, the machine’s behaviour. The kinematics of the two systems and their impact on the motorcycle performance is analysed and compared to the well known telescopic fork suspension system. Stability study for both systems is carried out by means of root-loci methods, in which the main oscillation modes, weave and wobble, are studied and compared to the baseline model
Passive mode locking of a Tm,Ho:KY(WO4)(2) laser around 2 μm
We report the first demonstration, to our knowledge, of passive mode locking in a Tm3+, Ho3+-codoped KYWO42 laser operating in the 2000-2060 nm spectral region. An InGaAsSb-based quantum well semiconductor saturable absorber mirror is used for the initiation and stabilization of the ultrashort pulse generation. Pulses as short as 3.3 ps were generated at 2057 nm with average output powers up to 315 mW at a pulse repetition frequency of 132 MHz for 1.15 W of absorbed pump power at 802 nm from a Ti:sapphire laser
The Borrego Mountain, California, earthquake of 9 April 1968: A preliminary report
The largest earthquake to hit California in more than 15 years occurred at
02:28:58.9 GCT on 9 April 1968 near Borrego Mountain, on the western edge of
the Imperial Valley. The Seismological Laboratory at Pasadena has tentatively
assigned the shock a magnitude of 6.5, an epicentral location of 33 ° 08.8' N, 116 °
07.5' W, and a focal depth of 20 km. The earthquake was felt throughout most
of southern California and adjacent areas, but the absence of severe damage and
casualties was in large part due to the relatively undeveloped nature of the epicentral
region. Indeed, it would have been difficult to pick a location in the southernmost
part of the State more remote from centers of population
Two dimensional lattice Gross--Neveu model with domain-wall fermions
We investigate the two dimensional lattice Gross--Neveu model in large flavor
number limit using the domain-wall fermion formulation, as a toy model of
lattice QCD. We study nonperturbative behaviorn of the restoration of chiral
symmetry of the domain-wall fermions as the extent of the extra dimension
is increased to infinity. We find the the parity broken phase (Aoki
phase) for finite , and study the phase diagram, which is related to the
mechanism of the chiral restoration in limit. The continuum
limit is taken and scaling violation of observables vanishes in
limit. We also examine the systematic dependencies of
observables to the parameters.Comment: 36 pages (26 figures), Latex (epsf style-file needed
Wood Dust in Joineries and Furniture Manufacturing: An Exposure Determinant and Intervention Study.
: To assess wood dust exposures and determinants in joineries and furniture manufacturing and to evaluate the efficacy of specific interventions on dust emissions under laboratory conditions. Also, in a subsequent follow-up study in a small sample of joinery workshops, we aimed to develop, implement, and evaluate a cost-effective and practicable intervention to reduce dust exposures. : Personal inhalable dust (n = 201) was measured in 99 workers from 10 joineries and 3 furniture-making factories. To assess exposure determinants, full-shift video exposure monitoring (VEM) was conducted in 19 workers and task-based VEM in 32 workers (in 7 joineries and 3 furniture factories). We assessed the efficacy of vacuum extraction on hand tools and the use of vacuum cleaners instead of sweeping and dry wiping under laboratory conditions. These measures were subsequently implemented in three joinery workshops with 'high' (>4 mg m-3) and one with 'low' (<2 mg m-3) baseline exposures. We also included two control workshops (one 'low' and one 'high' exposure workshop) in which no interventions were implemented. Exposures were measured 4 months prior and 4 months following the intervention. : Average (geometric means) exposures in joinery and furniture making were 2.5 mg m-3 [geometric standard deviations (GSD) 2.5] and 0.6 mg m-3 (GSD 2.3), respectively. In joinery workers cleaning was associated with a 3.0-fold higher (P < 0.001) dust concentration compared to low exposure tasks (e.g. gluing), while the use of hand tools showed 3.0- to 11.0-fold higher (P < 0.001) exposures. In furniture makers, we found a 5.4-fold higher exposure (P < 0.001) with using a table/circular saw. Laboratory efficiency experiments showed a 10-fold decrease in exposure (P < 0.001) when using a vacuum cleaner. Vacuum extraction on hand tools combined with a downdraft table reduced exposures by 42.5% for routing (P < 0.1) and 85.5% for orbital sanding (P < 0.001). Following intervention measures in joineries, a borderline statistically significant (P < 0.10) reduction in exposure of 30% was found in workshops with 'high' baseline exposures, but no reduction was shown in the workshop with 'low' baseline exposures. : Wood dust exposure is high in joinery workers and (to a lesser extent) furniture makers with frequent use of hand tools and cleaning being key drivers of exposure. Vacuum extraction on hand tools and alternative cleaning methods reduced workplace exposures substantially, but may be insufficient to achieve compliance with current occupational exposure limits.<br/
- …
