83 research outputs found

    Reliability of capturing foot parameters using digital scanning and the neutral suspension casting technique

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A clinical study was conducted to determine the intra and inter-rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques.</p> <p>Methods</p> <p>Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm), forefoot width (mm), rearfoot width (mm), medial arch height (mm), lateral arch height (mm) and forefoot to rearfoot alignment (degrees). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine the intra and inter-rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and smallest real difference (SRD).</p> <p>Results</p> <p>ICC values for all foot parameters using digital scanning ranged between 0.81-0.99 for both intra and inter-rater reliability. For neutral suspension casting technique inter-rater reliability values ranged from 0.57-0.99 and intra-rater reliability values ranging from 0.36-0.99 for rater 1 and 0.49-0.99 for rater 2.</p> <p>Conclusions</p> <p>The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting.</p

    The effectiveness of manual stretching in the treatment of plantar heel pain: a systematic review

    Get PDF
    Background: Plantar heel pain is a commonly occurring foot complaint. Stretching is frequently utilised as a treatment, yet a systematic review focusing only on its effectiveness has not been published. This review aimed to assess the effectiveness of stretching on pain and function in people with plantar heel pain. Methods: Medline, EMBASE, CINAHL, AMED, and The Cochrane Library were searched from inception to July 2010. Studies fulfilling the inclusion criteria were independently assessed, and their quality evaluated using the modified PEDro scale. Results: Six studies including 365 symptomatic participants were included. Two compared stretching with a control, one study compared stretching to an alternative intervention, one study compared stretching to both alternative and control interventions, and two compared different stretching techniques and durations. Quality rating on the modified Pedro scale varied from two to eight out of a maximum of ten points. The methodologies and interventions varied significantly between studies, making meta-analysis inappropriate. Most participants improved over the course of the studies, but when stretching was compared to alternative or control interventions, the changes only reached statistical significance in one study that used a combination of calf muscle stretches and plantar fascia stretches in their stretching programme. Another study comparing different stretching techniques, showed a statistically significant reduction in some aspects of pain in favour of plantar fascia stretching over calf stretches in the short term. Conclusions: There were too few studies to assess whether stretching is effective compared to control or other interventions, for either pain or function. However, there is some evidence that plantar fascia stretching may be more effective than Achilles tendon stretching alone in the short-term. Appropriately powered randomised controlled trials, utilizing validated outcome measures, blinded assessors and long-term follow up are needed to assess the efficacy of stretching

    Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System.</p> <p>Methods</p> <p>The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC) with 95% confidence intervals (CI) were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM) calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD) was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability.</p> <p>Results</p> <p>The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines.</p> <p>Conclusion</p> <p>The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.</p

    Classification of the height and flexibility of the medial longitudinal arch of the foot

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The risk of developing injuries during standing work may vary between persons with different foot types. High arched and low arched feet, as well as rigid and flexible feet, are considered to have different injury profiles, while those with normal arches may sustain fewer injuries. However, the cut-off values for maximum values (subtalar position during weight-bearing) and range of motion (ROM) values (difference between subtalar neutral and subtalar resting position in a weight-bearing condition) for the medial longitudinal arch (MLA) are largely unknown. The purpose of this study was to identify cut-off values for maximum values and ROM of the MLA of the foot during static tests and to identify factors influencing foot posture.</p> <p>Methods</p> <p>The participants consisted of 254 volunteers from Central and Northern Denmark (198 m/56 f; age 39.0 ± 11.7 years; BMI 27.3 ± 4.7 kg/m<sup>2</sup>). Navicular height (NH), longitudinal arch angle (LAA) and Feiss line (FL) were measured for either the left or the right foot in a subtalar neutral position and subtalar resting position. Maximum values and ROM were calculated for each test. The 95% and 68% prediction intervals were used as cut-off limits. Multiple regression analysis was used to detect influencing factors on foot posture.</p> <p>Results</p> <p>The 68% cut-off values for maximum MLA values and MLA ROM for NH were 3.6 to 5.5 cm and 0.6 to 1.8 cm, respectively, without taking into account the influence of other variables. Normal maximum LAA values were between 131 and 152° and normal LAA ROM was between -1 and 13°. Normal maximum FL values were between -2.6 and -1.2 cm and normal FL ROM was between -0.1 and 0.9 cm. Results from the multivariate linear regression revealed an association between foot size with FL, LAA, and navicular drop.</p> <p>Conclusions</p> <p>The cut-off values presented in this study can be used to categorize people performing standing work into groups of different foot arch types. The results of this study are important for investigating a possible link between arch height and arch movement and the development of injuries.</p

    Effect of foot orthoses on lower extremity kinetics during running: a systematic literature review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Throughout the period of one year, approximately 50% of recreational runners will sustain an injury that disrupts their training regimen. Foot orthoses have been shown to be clinically effective in the prevention and treatment of several running-related conditions, yet the physical effect of this intervention during running remains poorly understood. The aim of this literature review was therefore to evaluate the effect of foot orthoses on lower extremity forces and pressure (kinetics) during running.</p> <p>Methods</p> <p>A systematic search of electronic databases including Medline (1966-present), CINAHL, SportDiscus, and The Cochrane Library occurred on 7 May 2008. Eligible articles were selected according to pre-determined criteria. Methodological quality was evaluated by use of the Quality Index as described by Downs & Black, followed by critical analysis according to outcome variables.</p> <p>Results</p> <p>The most widely reported kinetic outcomes were loading rate and impact force, however the effect of foot orthoses on these variables remains unclear. In contrast, current evidence suggests that a reduction in the rearfoot inversion moment is the most consistent kinetic effect of foot orthoses during running.</p> <p>Conclusion</p> <p>The findings of this review demonstrate systematic effects that may inform the direction of future research, as further evidence is required to define the mechanism of action of foot orthoses during running. Continuation of research in this field will enable targeting of design parameters towards biomechanical variables that are supported by evidence, and may lead to advancements in clinical efficacy.</p

    Development and evaluation of a tool for the assessment of footwear characteristics

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Footwear characteristics have been linked to falls in older adults and children, and the development of many musculoskeletal conditions. Due to the relationship between footwear and pathology, health professionals have a responsibility to consider footwear characteristics in the etiology and treatment of various patient presentations. In order for health professionals and researchers to accurately and efficiently critique an individual's footwear, a valid and reliable footwear assessment tool is required. The aim of this study was to develop a simple, efficient, and reliable footwear assessment tool potentially suitable for use in a range of patient populations.</p> <p>Methods</p> <p>Consideration of previously published tools, other footwear related literature, and clinical considerations of three therapists were used to assist in the development of the tool. The tool was developed to cover fit, general features, general structure, motion control properties, cushioning, and wear patterns. A total of 15 participants (who provided two pairs of shoes each) were recruited, and assessment using the scale was completed on two separate occasions (separated by 1 – 3 weeks) by a physiotherapist and a podiatrist on each participant's dominant foot. Intra-rater and inter-rater reliability were evaluated using intra-class correlation coefficients (ICCs) (model 2, 1) and the 95% limits of agreement (95% LOAs) for continuous items, and percentage agreement and kappa (κ) statistics for categorical items.</p> <p>Results</p> <p>All categorical items demonstrated high percentage agreement statistic for intra-rater (83 – 100%) and inter-rater (83 – 100%) comparisons. With the exception of last shape and objective measures used to categorise the adequacy of length, excellent intra-rater (ICC = 0.91 – 1.00) and inter-rater reliability (ICC = 0.90 – 1.00) was indicated for continuous items in the tool, including the motion control properties scale (0.91 – 0.95).</p> <p>Conclusion</p> <p>A comprehensive footwear assessment tool with good face validity has been developed to assist future research and clinical footwear assessment. Generally good reliability amongst all items indicates that the tool can be used with confidence in research and clinical settings. Further research is now required to determine the clinical validity of each item in various patient populations.</p

    Testing the proficiency to distinguish locations with elevated plantar pressure within and between professional groups of foot therapists

    Get PDF
    BACKGROUND: Identification of locations with elevated plantar pressures is important in daily foot care for patients with rheumatoid arthritis, metatarsalgia and diabetes. The purpose of the present study was to evaluate the proficiency of podiatrists, pedorthists and orthotists, to distinguish locations with elevated plantar pressure in patients with metatarsalgia. METHODS: Ten podiatrists, ten pedorthists and ten orthotists working in The Netherlands were asked to identify locations with excessively high plantar pressure in three patients with forefoot complaints. Therapists were instructed to examine the patients according to the methods used in their everyday clinical practice. Regions could be marked through hatching an illustration of a plantar aspect. A pressure sensitive platform was used to quantify the dynamic bare foot plantar pressures and was considered as 'Gold Standard' (GS). A pressure higher than 700 kPa was used as cut-off criterion for categorizing peak pressure into elevated or non-elevated pressure. This was done for both patient's feet and six separate forefoot regions: big toe and metatarsal one to five. Data were analysed by a mixed-model ANOVA and Generalizability Theory. RESULTS: The proportions elevated/non-elevated pressure regions, based on clinical ratings of the therapists, show important discrepancies with the criterion values obtained through quantitative plantar pressure measurement. In general, plantar pressures in the big toe region were underrated and those in the metatarsal regions were overrated. The estimated method agreement on clinical judgement of plantar pressures with the GS was below an acceptable level: i.e. all intraclass correlation coefficient's equal or smaller than .60. The inter-observer agreement for each discipline demonstrated worrisome results: all below .18. The estimated mutual agreements showed that there was virtually no mutual agreement between the professional groups studied. CONCLUSION: Identification of elevated plantar pressure through clinical evaluation is difficult, insufficient and may be potentially harmful. The process of clinical plantar pressure screening has to be re-evaluated. The results of this study point towards the merit of quantitative plantar pressure measurement for clinical practice
    corecore