2,489 research outputs found

    Words with the Maximum Number of Abelian Squares

    Full text link
    An abelian square is the concatenation of two words that are anagrams of one another. A word of length nn can contain Θ(n2)\Theta(n^2) distinct factors that are abelian squares. We study infinite words such that the number of abelian square factors of length nn grows quadratically with nn.Comment: To appear in the proceedings of WORDS 201

    Construction and Expected Performance of the Hadron Blind Detector for the PHENIX Experiment at RHIC

    Get PDF
    A new Hadron Blind Detector (HBD) for electron identification in high density hadron environment has been installed in the PHENIX detector at RHIC in the fall of 2006. The HBD will identify low momentum electron-positron pairs to reduce the combinatorial background in the e+e−e^{+}e^{-} mass spectrum, mainly in the low-mass region below 1 GeV/c2^{2}. The HBD is a windowless proximity-focusing Cherenkov detector with a radiator length of 50 cm, a CsI photocathode and three layers of Gas Electron Multipliers (GEM). The HBD uses pure CF4_{4} as a radiator and a detector gas. Construction details and the expected performance of the detector are described.Comment: QM2006 proceedings, 4 pages 3 figure

    Development of a Time Projection Chamber Using Gas Electron Multipliers (GEM-TPC)

    Get PDF
    We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%), Ar(70%)-C2H6(30%) and CF4). Detection efficiency of 99%, and spatial resolution of 79 μ\mum in the pad-row direction and 313 μ\mum in the drift direction were achieved. The test results show that the GEM-TPC meets the requirements for high energy heavy ion collision experiments. The configuration and performance of the GEM-TPC are described.Comment: 18 pages, 12 figures, published online in Nucl. Instr. and Meth.

    Design, Construction, Operation and Performance of a Hadron Blind Detector for the PHENIX Experiment

    Full text link
    A Hadron Blind Detector (HBD) has been developed, constructed and successfully operated within the PHENIX detector at RHIC. The HBD is a Cherenkov detector operated with pure CF4. It has a 50 cm long radiator directly coupled in a window- less configuration to a readout element consisting of a triple GEM stack, with a CsI photocathode evaporated on the top surface of the top GEM and pad readout at the bottom of the stack. This paper gives a comprehensive account of the construction, operation and in-beam performance of the detector.Comment: 51 pages, 39 Figures, submitted to Nuclear Instruments and Method

    Initial Development of a Patient-Reported Instrument Assessing Harm, Efficacy, and Misuse of Long-Term Opioid Therapy

    Get PDF
    Guidelines on long-term opioid therapy recommend frequent reassessment of harm, efficacy, and misuse of these potentially harmful and sometimes ineffective medications. In primary care, there is a need for a brief, patient-reported instrument. This report details the initial steps in the development of such an instrument. An interdisciplinary team of clinician-scientists performed four discrete steps in this study: (1) conceptualization of the purpose and function of the instrument, (2) assembly of an item pool, (3) expert rating on which items were most important to include in the instrument, and (4) modification of expert-selected items based on a reading level check and cognitive interviews with patients. A diverse panel of 47 subject matter experts was presented with 69 items to rate on a 1–9 scale in terms of importance for inclusion in the instrument. The panel highly rated 37 items: 8 related to harm, 4 related to efficacy, and 25 related to misuse. These 37 items were then tested for patient comprehension and modified as needed. Next steps in development will include further item reduction, testing against a gold standard, and assessment of the instrument’s effect on clinical outcomes

    A Hadron Blind Detector for the PHENIX Experiment

    Full text link
    A novel Hadron Blind Detector (HBD) has been developed for an upgrade of the PHENIX experiment at RHIC. The HBD will allow a precise measurement of electron-positron pairs from the decay of the light vector mesons and the low-mass pair continuum in heavy-ion collisions. The detector consists of a 50 cm long radiator filled with pure CF4 and directly coupled in a windowless configuration to a triple Gas Electron Multiplier (GEM) detector with a CsI photocathode evaporated on the top face of the first GEM foil.Comment: 4 pages, 3 figures, Quark Matter 2005 conference proceeding
    • …
    corecore